Black Friday Sale: Extra 5% Off in Your Cart. Free Shipping on $300+

Not what you were looking for? Find your system:

MRCOOL Universal Split R-454B 3 Ton heat pump condenser
MRCOOL Universal 3 ton spec card
MRCOOL Universal Split R-454B 3 Ton air handler
MRCOOL Universal Split R-454B 3 Ton heat pump condenser, side view
MRCOOL Universal Split R-454B 3 Ton heat pump condenser, alternate angle
MRCOOL Universal Split R-454B 3 Ton heat pump condenser, coil view
MRCOOL Universal Split R-454B 3 Ton air handler, side view
MRCOOL Universal Split R-454B family, air handler and condensers

MRCOOL

MRCOOL Universal Split R-454B 3 Ton Ducted Heat Pump System (Condenser + Air Handler)

Models: UHP18036-O + UAH18036-O

  • Cooling36,000 BTU
  • Efficiency18.0 SEER2
  • Heating10.0 HSPF2
  • Power120V or 208-240V
  • Complete ducted system: Condenser + Air Handler
  • 36,000 BTU heating and cooling
  • 18 SEER2 efficiency to keep power bills down
  • 10 HSPF2 heating efficiency
  • Variable-speed inverter adjusts output to hold your set temperature
$4,472.00

Out of stock. Text a pro for the next ship date.

Secure checkout through Shopify

  • Visa
  • Mastercard
  • American Express
  • Discover
  • PayPal
  • Apple Pay
  • Google Pay
  • Shop Pay
Questions? Text a licensed HVAC pro. (479) 488-3576 · Mon to Fri, 8 AM to 5 PM Central
Not sure about the size? Get a free size check by email

Tell us about the room. A licensed HVAC pro will email you the size that fits.

Product overview

About this system

The MRCOOL Universal Split R-454B 3 Ton Ducted Heat Pump System is a matched split heat pump system: an outdoor condenser and the indoor air handler built to work with it. It heats and cools through your existing ductwork. It is rated for 36,000 BTU/h of cooling and 37,000 BTU/h of heating, with 37,400 BTU/h of heat still available at 5°F. Efficiency is 18.0 SEER2, 12 EER2 and 10.0 HSPF2.

Electrical and operating range

It runs on 115/208/230V power with a minimum circuit ampacity of 29 A and a maximum fuse or breaker of 30 A. Sound level is 63 dB(A). It cools in outdoor temperatures from -22°F to 122°F and heats from -22°F to 75°F.

Size and connections

It measures 17.52 x 21.50 x 53.98 in (W x D x H) and weighs 149.25 lb. Refrigerant connections: 3/8 / 3/4 in. Maximum line length: 246 ft (75 m).

Need to heat and cool more than one room? Build a multi-room system.

Buying from Cool Air Depot

  • Authorized MRCOOL dealerNew equipment with the full MRCOOL factory warranty.
  • Free shippingThis item ships free.
  • 30-day returnsRequest a return within 30 days of delivery, or cancel free before your order ships. Return policy
  • Licensed HVAC supportText a pro at (479) 488-3576, Monday to Friday, 8 AM to 5 PM Central.

What's included

What's in the box

In the box

  • Outdoor unitHeat pump condenser
  • Indoor unitAir handler

Not included: the line set.

Specifications

Specs

Matched pair

Outdoor SKUUHP18036-O
Indoor SKUUAH18036-O
Cooling capacity (Btu/h)36000
Heating capacity at 47 F (Btu/h)37000
SEER218.0
EER2 at 95 F12
HSPF2 Region IV10.0
HSPF2 Region V8.2
Cooling capacity min / max (Btu/h)12100 / 43000
Heating capacity at 47 F min / max (Btu/h)11400 / 47000
Heating capacity at 17 F (Btu/h)31000
Heating capacity at 5 F (Btu/h)37400
COP at 47 F3.50
COP at 5 F1.90
System power input cooling W, rated (range)3000 (910-4370)
System power input heating W, rated (range)3098 (755-4210)
Moisture removal (L/h)3.41
Cooling operating range (F)-22 to 122
Heating operating range (F)-22 to 75

Air handler

Net dimensions W x D x H (in)17.52 x 21.50 x 53.98
Packing dimensions W x D x H (in)20.47 x 31.10 x 57.09
Net / gross weight (lb)149.25 / 182.10
External static pressure (in. W.G.)0-1.0

Air handler electrical

Power supply115 / 208 / 230V, 1 phase, 60 Hz
MCA at 115V (A)10.0
MCA at 208/230V (A)6.0
MOP at 115V (A)15.0
MOP at 208/230V (A)15.0
Minimum wire size (AWG)14
Indoor fan motor RLA (A)4.5
Auxiliary heat at 115VNot available

Heat pump condenser

Net dimensions W x D x H (in)38.58 x 16.34 x 38.39
Packing dimensions W x D x H (in)45.08 x 19.68 x 42.52
Net / gross weight (lb)204.15 / 235.23
Outdoor airflow max (CFM)3001.9
Outdoor noise (dBA)63
Power supply208 / 230V, 1 phase, 60 Hz
MCA (A)29
Max fuse or MOP (A)30
Compressor typeTWIN-ROTARY
Compressor modelEKPQ420D1UMUA
Compressor RLA (A)20.5
Outdoor fan motor RLA (A)2.4
Outdoor fan motor (W)250
Communication wiring (AWG)20-2

Refrigerant

TypeR-454B
Factory charge (oz)126.99
Oil typeVG75
Oil charge (mL)1460

Piping

Liquid / gas size (in)3/8 / 3/4
Connection methodFlare or Quick Connect
Maximum piping length246 ft (75 m)
Maximum drop height98.4 ft (30 m)
Maximum pre-charged length24.6 ft (7.5 m)
Additional refrigerant0.7 oz/ft (65 g/m)
Throttle type indoor / outdoorEXV / EXV
Line set includedNo

Figures come from MRCOOL's spec sheet, installation manual and AHRI certificate for this model. MRCOOL notes that spec sheet figures may change during production.

Warranty

MRCOOL's factory warranty

10 yearParts and compressor
2 yearLabor

Covered

  • Covers the original owner. It does not transfer to a new owner.
  • Labor coverage starts on day 91 after your proof-of-purchase date and is capped at the purchase price of the product.
Warranty exclusions
  • Shipping and refrigerant costs
  • Damage from faulty installation or a unit installed against code
  • A unit moved from its first install address

Summary of MRCOOL's limited warranty for the Universal R-454B series. The PDF below is the full terms, including when professional installation is required. MRCOOL may ask for a licensed HVAC technician to diagnose a problem before approving a claim. Claims go to MRCOOL at (270) 366-0457 or support@mrcool.com.

Documents

Manuals and documents

Check the ratings yourself: enter AHRI reference number 217730330, date 09-08-2025 and certificate number 134018369424604187 at ahridirectory.org.

FAQ

Questions people ask

Still have a question? A licensed HVAC pro answers texts Monday to Friday, 8 AM to 5 PM Central.

Text a pro: (479) 488-3576
Who installs it?

A licensed HVAC technician. It's built for professional installation, so any local HVAC company can install it.

Which line set does it use?

It connects with a standard line set, sold separately so you can get the exact length you need.

What's the warranty?

MRCOOL gives the original owner 10 years on parts and compressor and 2 years of limited labor coverage starting on day 91. See the warranty section above for details.

See every size and series

Compare this system with other MRCOOL sizes and series, or answer four quick questions to see every match.