Not what you were looking for? Find your system:
MRCOOL
MRCOOL Universal Split R-454B 4 Ton Ducted Heat Pump System (Condenser + Air Handler)
Models: UHP18048-O + UAH18048-O
- Cooling48,000 BTU
- Efficiency17.5 SEER2
- Heating9.5 HSPF2
- Power120V or 208-240V
- Complete ducted system: Condenser + Air Handler
- 48,000 BTU heating and cooling
- 17.5 SEER2 efficiency to keep power bills down
- 9.5 HSPF2 heating efficiency
- Variable-speed inverter adjusts output to hold your set temperature
In stock
Free shipping · Ships in 1–2 business days
Secure checkout through Shopify
- Authorized MRCOOL dealer
- Licensed HVAC contractor
- Free shipping
- 30-day returns
- Free cancellation before it ships
Authorized MRCOOL dealer. You get new, genuine MRCOOL equipment with the full MRCOOL warranty. A licensed HVAC pro answers your texts.
About usRun by a licensed HVAC contractor. Text our team your sizing or install questions, Monday to Friday, 8 AM to 5 PM Central.
About usThis ships free. Orders under $300 ship for $19.95. You get tracking by email when it ships.
Shipping details30-day returns. Ask within 30 days of delivery. Returns ship back by carrier from your home. Send it back unopened for a refund, minus a 15% restocking fee. If it arrives damaged, broken or wrong, there is no fee and we pay the return shipping.
Return policyFree cancellation. Cancel before your order ships and you pay nothing.
Return policy Questions? Text a licensed HVAC pro. (479) 488-3576 · Mon to Fri, 8 AM to 5 PM CentralProduct overview
About this system
The MRCOOL Universal Split R-454B 4 Ton Ducted Heat Pump System is a matched split heat pump system: an outdoor condenser and the indoor air handler built to work with it. It heats and cools through your existing ductwork. It is rated for 48,000 BTU/h of cooling and 48,000 BTU/h of heating, with 48,000 BTU/h of heat still available at 5°F. Efficiency is 17.5 SEER2, 12 EER2 and 9.5 HSPF2.
Electrical and operating range
It runs on 115/208/230V power with a minimum circuit ampacity of 38 A and a maximum fuse or breaker of 40 A. Sound level is 65 dB(A). It cools in outdoor temperatures from -22°F to 122°F and heats from -22°F to 75°F.
Size and connections
It measures 21.50 x 21.50 x 55.94 in (W x D x H) and weighs 186.51 lb. Refrigerant connections: 3/8 / 3/4 in. Maximum line length: 246 ft (75 m).
Need to heat and cool more than one room? Build a multi-room system.
Buying from Cool Air Depot
- Authorized MRCOOL dealerNew equipment with the full MRCOOL factory warranty.
- Free shippingThis item ships free.
- 30-day returnsRequest a return within 30 days of delivery, or cancel free before your order ships. Return policy
- Licensed HVAC supportText a pro at (479) 488-3576, Monday to Friday, 8 AM to 5 PM Central.
What's included
What's in the box
In the box
- Outdoor unitHeat pump condenser
- Indoor unitAir handler
Not included: the line set.
Specifications
Specs
Matched pair
| Outdoor SKU | UHP18048-O |
|---|---|
| Indoor SKU | UAH18048-O |
| Cooling capacity (Btu/h) | 48000 |
| Heating capacity at 47 F (Btu/h) | 48000 |
| SEER2 | 17.5 |
| EER2 at 95 F | 12 |
| HSPF2 Region IV | 9.5 |
| HSPF2 Region V | 7.7 |
| Cooling capacity min / max (Btu/h) | 18000 / 52000 |
| Heating capacity at 47 F min / max (Btu/h) | 13500 / 52000 |
| Heating capacity at 17 F (Btu/h) | 48000 |
| Heating capacity at 5 F (Btu/h) | 48000 |
| COP at 47 F | 3.28 |
| COP at 5 F | 2.00 |
| System power input cooling W, rated (range) | 4266 (1300-4870) |
| System power input heating W, rated (range) | 4521 (925-3880) |
| Moisture removal (L/h) | 4.94 |
| Cooling operating range (F) | -22 to 122 |
| Heating operating range (F) | -22 to 75 |
Air handler
| Net dimensions W x D x H (in) | 21.50 x 21.50 x 55.94 |
|---|---|
| Packing dimensions W x D x H (in) | 25.00 x 31.10 x 59.84 |
| Net / gross weight (lb) | 186.51 / 232.14 |
| External static pressure (in. W.G.) | 0-0.8 |
Air handler electrical
| Power supply | 115 / 208 / 230V, 1 phase, 60 Hz |
|---|---|
| MCA at 115V (A) | 17.5 |
| MCA at 208/230V (A) | 11.0 |
| MOP at 115V (A) | 20.0 |
| MOP at 208/230V (A) | 15.0 |
| Minimum wire size (AWG) | 14 |
| Indoor fan motor RLA (A) | 8 |
| Auxiliary heat at 115V | Not available |
Heat pump condenser
| Net dimensions W x D x H (in) | 38.58 x 16.34 x 38.39 |
|---|---|
| Packing dimensions W x D x H (in) | 45.08 x 19.68 x 42.52 |
| Net / gross weight (lb) | 201.50 / 232.59 |
| Outdoor airflow max (CFM) | 3037.2 |
| Outdoor noise (dBA) | 65 |
| Power supply | 208 / 230V, 1 phase, 60 Hz |
| MCA (A) | 38 |
| Max fuse or MOP (A) | 40 |
| Compressor type | ROTARY |
| Compressor model | MTH550UKPC8FU |
| Compressor RLA (A) | 28 |
| Outdoor fan motor RLA (A) | 2 |
| Outdoor fan motor (W) | 250 |
| Communication wiring (AWG) | 20-2 |
Refrigerant
| Type | R-454B |
|---|---|
| Factory charge (oz) | 134.04 |
| Oil type | HAF68D1C |
| Oil charge (mL) | 1800 |
Piping
| Liquid / gas size (in) | 3/8 / 3/4 |
|---|---|
| Connection method | Flare or Quick Connect |
| Maximum piping length | 246 ft (75 m) |
| Maximum drop height | 98.4 ft (30 m) |
| Maximum pre-charged length | 24.6 ft (7.5 m) |
| Additional refrigerant | 0.7 oz/ft (65 g/m) |
| Throttle type indoor / outdoor | EXV / EXV |
| Line set included | No |
Figures come from MRCOOL's spec sheet, installation manual and AHRI certificate for this model. MRCOOL notes that spec sheet figures may change during production.
Warranty
MRCOOL's factory warranty
Covered
- Covers the original owner. It does not transfer to a new owner.
- Labor coverage starts on day 91 after your proof-of-purchase date and is capped at the purchase price of the product.
Warranty exclusions
- Shipping and refrigerant costs
- Damage from faulty installation or a unit installed against code
- A unit moved from its first install address
Summary of MRCOOL's limited warranty for the Universal R-454B series. The PDF below is the full terms, including when professional installation is required. MRCOOL may ask for a licensed HVAC technician to diagnose a problem before approving a claim. Claims go to MRCOOL at (270) 366-0457 or support@mrcool.com.
Documents
Manuals and documents
Install and use
Specs and ratings
Warranty
For your installer
Check the ratings yourself: enter AHRI reference number 217730331, date 09-08-2025 and certificate number 134018369568199806 at ahridirectory.org.
FAQ
Questions people ask
Still have a question? A licensed HVAC pro answers texts Monday to Friday, 8 AM to 5 PM Central.
Text a pro: (479) 488-3576Who installs it?
A licensed HVAC technician. It's built for professional installation, so any local HVAC company can install it.
Which line set does it use?
It connects with a standard line set, sold separately so you can get the exact length you need.
What's the warranty?
MRCOOL gives the original owner 10 years on parts and compressor and 2 years of limited labor coverage starting on day 91. See the warranty section above for details.
See every size and series
Compare this system with other MRCOOL sizes and series, or answer four quick questions to see every match.
Pictures and video
See the MRCOOL Universal 4 Ton heat pump up close
9 things to know








Add what the job needs. The line set is sold on its own so you can pick the length. MRCOOL No-Vac line sets for the Universal come in 15 ft, 25 ft, 35 ft or 50 ft. They come with R-454B already in them. Want backup heat? Add a 8 kW, 10 kW, 15 kW or 20 kW heat kit. Need a thermostat? The MRCOOL Smart WiFi Thermostat works with it.
Pictures and videos are from MRCOOL. Need a different size? See the 2 Ton, 2.5 Ton, 3 Ton or 5 Ton. Not sure which size your home needs? Use our whole-home picker or read our MRCOOL Universal Series guide.
Installation
How the MRCOOL Universal 4 Ton goes in
The Universal is a central heat pump. The air handler hooks to your ducts inside. The heat pump sits outside. Two copper lines and a few wires join them. Here is the whole job, start to finish.
The install, step by step
- Pick the two spots. The air handler can go in a closet, a basement, an attic or a garage. It needs a base that can hold about 187 lb. The outdoor unit needs a level spot with open air around it.
- Set the air handler. It can blow up, down, left or right. For some positions the coil inside is turned around first. The manual shows how. In a garage, the heating parts have to sit at least 18 inches above the floor.
- Hook up the ducts. The supply duct and the return duct connect to the air handler. Flexible duct collars help keep noise out of the ducts. This unit is made for ducts. It is not made to blow straight into a room.
- Put in the filter. This size takes a 20 x 20 x 1 inch filter.
- Run the drain. Use PVC pipe with a trap close to the unit. The end of the pipe should sit at least 2 inches above the ground. If the air handler lies on its side, or sits above a finished room, it also needs a second drain pan under it.
- Set the outdoor unit. Fit the drain joint. Bolt the unit to a pad or a wall bracket with M10 bolts. It weighs about 202 lb. Where it snows, raise it at least 6 inches above the snow line.
- Do the wiring. Turn the breakers off first. The outdoor unit gets its own 208/230V circuit. The air handler gets its own circuit too. Low-voltage wires link the air handler, the outdoor unit and the thermostat. Match each wire to the diagram on the unit.
- Connect the copper lines. A 3/8 inch line and a 3/4 inch line join the two units. A MRCOOL No-Vac line set comes with R-454B already in it and has Quick-Connect fittings. A plain copper line set is flared and tightened with a torque wrench.
- With plain copper, clear the lines. Run a vacuum pump on the lines for at least 15 minutes, or down to 500 microns. Close it off and wait 5 minutes. The reading should hold. Then open both valves with a hex wrench.
- Check for leaks. Check every joint with a leak detector or leak-check bubbles. Then wrap the lines and fittings in insulation.
- Hook up the thermostat. The Universal works with a regular 24V thermostat.
- Turn it on and test it. Run it in Cool. Check that the air blows, the water drains, and nothing shakes or rattles.
Tools the job takes
- Level, tape measure, drill and screwdrivers
- Tools for joining ductwork
- PVC pipe, a cutter and glue for the drain
- Wire strippers
- An adjustable wrench and a torque wrench
- Hex (Allen) wrenches
- Leak detector or leak-check fluid
- With a plain copper line set: pipe cutter, reamer, flaring tool, vacuum pump, manifold gauge set and a micron gauge
Good to know first
- Power outside: the outdoor unit is wired to its own 208/230V circuit. Size the wire for at least 38 amps. The biggest breaker it can use is 40 amps.
- Power inside: the air handler runs on 115V or 208/230V and senses which one by itself. Size the wire for at least 17.5 amps on 115V or 11.0 amps on 208/230V. A heat kit only works on 208/230V.
- Line set: sold on its own, 3/8 and 3/4 inch. The run can be up to 246 ft long. One unit can sit up to 98.4 ft higher than the other.
- Refrigerant: the outdoor unit comes filled with R-454B for up to 24.6 ft of line. A longer run of plain copper line needs 0.7 oz more for each extra foot.
- Not in the box: the line set, a thermostat, the drain pipe, the power wires, and a pad or risers for the outdoor unit.
These steps follow MRCOOL's Universal R-454B installation and owner's manual. The full manual is under Manuals on this page. Follow your local codes.
Day to day
Living with the MRCOOL Universal
Thermostat and controls
- It works with a regular 24V thermostat, from 1 heat and 1 cool up to 3 heat and 2 cool.
- Want to run it from your phone? The MRCOOL Smart WiFi Thermostat is a 24V thermostat with an app.
- MRCOOL also makes a wired controller for it.
- A small screen on the air handler's control board shows the set temperature. If something is wrong, it flashes a code.
Comfort
- The inverter speeds up and slows down, so the temperature stays even.
- The air handler runs as quiet as 33 dB(A) on low. The outdoor unit is rated 65 dB(A).
- The airflow can be set to fit your ducts.
- A heat kit adds electric backup heat for the coldest days.
Care
- Keep the filter clean. Turn the unit off before you take the filter out. If you wash it, let it dry out of the sun.
- Before each season, check that nothing blocks the air going in or out, inside and outside.
- If you have a heat kit, leave the power to the outdoor unit on when it is below freezing.
- Wipe the cabinet with a soft, damp cloth. Do not use harsh cleaners.
What is the MRCOOL Universal Series?
It is a ducted inverter heat pump. It heats and cools a whole home through its ducts. A Universal condenser sits outside and a matching Universal air handler sits inside. It uses R-454B refrigerant.
What comes with this system?
The 4 Ton Universal inverter heat pump condenser, model UHP18048-O, and the matching 4 Ton multi-position air handler, model UAH18048-O. You can also buy the condenser or the air handler by itself.
How cold can it heat?
It heats when it is as cold as 22°F below zero outside. MRCOOL rates it for up to 100% of its heat at 13°F below zero.
How hot can it be outside and still cool?
Up to 122°F. MRCOOL rates it for up to 100% of its cooling at 110°F.
What size line set does it take?
A 3/8 inch liquid line and a 3/4 inch gas line. MRCOOL No-Vac line sets in that size come in 15 ft, 25 ft, 35 ft or 50 ft. They come with R-454B already in them and have Quick-Connect fittings. A plain copper line set with flare nuts works too.
How long can the line set be?
Up to 246 ft. One unit can sit up to 98.4 ft higher than the other.
Does the outdoor unit come with refrigerant in it?
Yes. It comes filled with R-454B for up to 24.6 ft of line. A longer run of plain copper line needs 0.7 oz more for each extra foot.
What power does it need?
The outdoor unit is wired to its own 208/230V circuit. Size the wire for at least 38 amps. The biggest breaker it can use is 40 amps. The air handler has its own circuit. It runs on 115V or 208/230V and senses which one by itself.
What thermostat does it work with?
A regular 24V thermostat, from 1 heat and 1 cool up to 3 heat and 2 cool. A thermostat is not in the box. The MRCOOL Smart WiFi Thermostat is a 24V thermostat you can run from your phone.
Which heat kits fit?
The 8 kW, 10 kW, 15 kW or 20 kW heat kits fit the 4 Ton air handler. A heat kit is an add-on for backup electric heat. It only works when the air handler is on 208/230V.
Can the air handler lie on its side?
Yes. It can be set up to blow up, down, left or right. On its side, it needs a second drain pan under it.
What size filter does it take?
A 20 x 20 x 1 inch filter.
How big and how heavy is it?
The outdoor unit is 38.58 x 16.34 x 38.39 inches (wide x deep x tall) and weighs about 202 lb.The air handler is 21.50 x 21.50 x 55.94 inches (wide x deep x tall) and weighs about 187 lb.
How loud is it?
MRCOOL lists the air handler at 33 dB(A) on low.The outdoor unit is rated 65 dB(A).
Is it ENERGY STAR?
MRCOOL's brochure lists every Universal size as meeting ENERGY STAR version 6.1, and ENERGY STAR Cold Climate. This system is rated 17.5 SEER2 and 9.5 HSPF2.
Can it take the place of a furnace and an air conditioner?
Yes. It both heats and cools through your ducts, so one system does both jobs. MRCOOL made the air handler the same width as most furnaces. Want backup heat? Add an electric heat kit.
What tools does the install take?
A level, a drill, tools for joining ductwork, PVC pipe and glue for the drain, wire strippers, an adjustable wrench, a torque wrench, hex wrenches and a leak detector. A plain copper line set also takes a pipe cutter, a flaring tool, a vacuum pump and gauges.
How is it different from a MRCOOL DIY mini split?
A DIY mini split heats and cools one room and has no ducts. The Universal heats and cools the whole home through its ducts. See the DIY mini splits or every Universal size.
Best for: Any winter, hot or cold. The best heat pump MRCOOL makes, with a labor warranty too.
Add a heat kitOptional backup electric heat
Add a pre-charged line setOptional, sold separately

