Not what you were looking for? Find your system:
MRCOOL Olympus 4th Gen Air Handlers
MRCOOL Olympus E Star 18,000 BTU Indoor Unit Only, 230V (Outdoor Unit Sold Separately) (O-18-HP-WMAH-230C-O)
Model O-18-HP-WMAH-230C-O
Indoor unit only. It needs the matching outdoor unit to heat and cool. Most people get both together.
Get the complete system: indoor + outdoor$1,867Already have the outdoor unit? Add this one to your cart below.
- Cooling18,000 BTU
- Efficiency21.4 SEER2
- Heating11.0 HSPF2
- Power208-240V
- RefrigerantR-454B
- 18,000 BTU heating and cooling for up to 800 sq ft
- Ductless: heats and cools one room with no ductwork to install
- 23.5 SEER2 efficiency to keep power bills down
- Contractor-grade quality and efficiency
- Control it with the remote, your phone, Alexa or Google Assistant
In stock
Free shipping · Ships in 1–2 business days
Secure checkout through Shopify
- Authorized MRCOOL dealer
- Licensed HVAC contractor
- Free shipping
- 30-day returns
- Free cancellation before it ships
Authorized MRCOOL dealer. You get new, genuine MRCOOL equipment with the full MRCOOL warranty. A licensed HVAC pro answers your texts.
About usRun by a licensed HVAC contractor. Text our team your sizing or install questions, Monday to Friday, 8 AM to 5 PM Central.
About usThis ships free. Orders under $300 ship for $19.95. You get tracking by email when it ships.
Shipping details30-day returns. Ask within 30 days of delivery. Returns ship back by carrier from your home. Send it back unopened for a refund, minus a 15% restocking fee. If it arrives damaged, broken or wrong, there is no fee and we pay the return shipping.
Return policyFree cancellation. Cancel before your order ships and you pay nothing.
Return policyAdd to your orderChecked to fit this unit
-
MRCOOL Olympus 16 ft Flared Line Set, 1/4 x 1/2 in (for 18K Indoor Units) (MC16-1412) Olympus flared copper line set, 1/4 x 1/2 in, the pipe size this unit uses. Not included with this unit.$133.00
-
MRCOOL Olympus 25 ft Flared Line Set, 1/4 x 1/2 in (for 18K Indoor Units) (MC25-1412) Olympus flared copper line set, 1/4 x 1/2 in, the pipe size this unit uses$137.00
-
MRCOOL Olympus 50 ft Flared Line Set, 1/4 x 1/2 in (for 18K Indoor Units) (MC50-1412K) Olympus flared copper line set, 1/4 x 1/2 in, the pipe size this unit uses$315.00
Product overview
About this unit
The MRCOOL Olympus E Star 18,000 BTU indoor unit (model O-18-HP-WMAH-230C-O) is a wall-mounted air handler for one room or open area of up to 800 sq ft. It runs on 208/230V power and is sold without an outdoor unit. Paired with the matching Olympus E Star 18,000 BTU outdoor unit (model O-ES-18-HP-C-230C-O1), the system is rated 21.4 SEER2 and 11 HSPF2.
What you need to complete the system
Add the matching outdoor unit, model O-ES-18-HP-C-230C-O1, and an Olympus flared line set in 1/4 x 1/2 in. The line set is sold separately in 16, 25 and 50 ft lengths.
Features
The indoor unit runs as quietly as 19.5 dB(A) on its lowest fan setting. The Follow Me feature lets the remote sense the temperature where you are sitting.
Buying from Cool Air Depot
- Authorized MRCOOL dealerNew equipment with the full MRCOOL factory warranty.
- Free shippingThis item ships free.
- 30-day returnsRequest a return within 30 days of delivery, or cancel free before your order ships. Return policy
- Licensed HVAC supportText a pro at (479) 488-3576, Monday to Friday, 8 AM to 5 PM Central.
What's included
What's in the box
In the box
- Indoor unitO-18-HP-WMAH-230C-O
Not included: the outdoor unit (O-ES-18-HP-C-230C-O1) and the Olympus flared line set.
Specifications
Specs
Performance
| Cooling capacity | 18000 Btu/h |
|---|---|
| Heating capacity | 18000 Btu/h |
| SEER2 | 21.4 |
| EER2 | 12.5 |
| HSPF2-4 | 11.0 |
| HSPF2-5 | 8.5 |
| Indoor airflow Turbo/Hi/Mi/Lo/Si | 635.7 / 500.3 / 359.0 / 294.3 / 294.3 CFM |
| Indoor noise Turbo/Hi/Mi/Lo/Si | 49.5 / 45.0 / 38.0 / 31.5 / 19.5 dB(A) |
| Refrigerant | R-454B |
Electrical
| Power supply | 208/230V, 60Hz, 1Ph |
|---|---|
| Indoor minimum circuit | 3.0 A |
| Indoor maximum fuse | 15.0 A |
| Outdoor minimum circuit | 19.0 A |
| Outdoor maximum fuse | 20.0 A |
Dimensions
| Indoor net W x D x H | 40.31 x 9.69 x 12.64 in |
|---|---|
| Outdoor net W x D x H | 35.04 x 13.46 x 26.50 in |
| Indoor packing W x D x H | 43.11 x 12.80 x 15.75 in |
| Outdoor packing W x D x H | 39.17 x 15.67 x 29.13 in |
| Indoor net / gross weight | 27.34 / 36.60 lb |
| Outdoor net / gross weight | 99.87 / 107.80 lb |
Piping
| Refrigerant charge | 55.38 oz |
|---|---|
| Liquid / gas pipe size | 1/4 / 1/2 in |
| Standard pipe length | 25 ft |
| Minimum pipe run | 9.84 ft |
| Maximum line length | 98.4 ft |
| Maximum elevation | 65.6 ft |
| Connecting pipe assembly | Add the line set length you need |
Figures come from MRCOOL's spec sheet, installation manual and AHRI certificate for this model. MRCOOL notes that spec sheet figures may change during production.
Warranty
MRCOOL's factory warranty
Covered
- Starts on your proof-of-purchase date. No registration is needed.
- Parts include the remote, the Wi-Fi dongle, pre-charged line sets and the parts inside the indoor and outdoor units (the compressor has its own 7-year term).
Warranty exclusions
- Labor, shipping and refrigerant costs
- Damage from an install that doesn't follow the manual, local codes or permits
- A unit moved from its first install address
Summary of MRCOOL's limited warranty for the Olympus series (rev. 05.12.25). The PDF below is the full terms. MRCOOL may ask for a licensed HVAC technician to diagnose a problem before approving a claim. Claims go to MRCOOL at (270) 366-0457 or support@mrcool.com.
Documents
Manuals and documents
Install and use
Specs and ratings
Warranty
For your installer
Check the ratings yourself: enter AHRI reference number 217447808, date 09-29-2025 and certificate number 134036452525404236 at ahridirectory.org.
FAQ
Questions people ask
Still have a question? A licensed HVAC pro answers texts Monday to Friday, 8 AM to 5 PM Central.
Text a pro: (479) 488-3576Who installs it?
A licensed HVAC technician. It's built for professional installation, so any local HVAC company can install it.
Which line set does it use?
It uses an Olympus flared line set in the matching pipe size, sold separately so you can pick your length.
How long can the line run be?
MRCOOL lists up to 98.4 ft of line and 65.6 ft of height difference for this size.
What's the warranty?
MRCOOL covers parts for 5 years and the compressor for 7 years from your proof-of-purchase date, with no registration needed. See the warranty section above for details.
Pictures and video
See the MRCOOL Olympus E Star up close
The Olympus line in 22 seconds
A short video from MRCOOL. Olympus is its high-efficiency mini split line, with a 5 year parts and 7 year compressor warranty.
6 things to know



This is the indoor unit by itself. It pairs with the 18,000 BTU outdoor unit. Want both in one order? See the complete 18,000 BTU system. The line set is sold on its own: 16 ft, 25 ft or 50 ft.
Pictures and video are from MRCOOL. They show the complete system.
Installation
How the Olympus E Star 18,000 BTU goes in
The Olympus E Star hooks up the classic way. The copper lines join with flare nuts. Then a vacuum pump clears the air out of the lines before the valves are opened. Here is the whole job, start to finish.
The install, step by step
- Pick the two spots. The indoor unit goes at least 6 ft above the floor, in a room with a ceiling at least 7.3 ft high. The outdoor unit needs a level spot with room for air around it.
- Put up the wall plate. Use the cardboard template to mark the holes. Make the plate level and screw it to the wall.
- Drill the wall hole. One hole, 2.5 inches wide. Tilt it so the outside end sits about 1/4 inch lower and water runs out.
- Get the lines and the drain hose ready. Hook the drain hose to the indoor unit on the same side as the copper lines. Bundle the lines, the cable and the hose, with the hose on the bottom.
- Hang the indoor unit. Feed the bundle through the wall. Hook the unit on the top of the plate and press the bottom in. It weighs about 27 lb.
- Set the outdoor unit. Fit the drain joint. Bolt the unit to a level pad or a wall bracket with M10 bolts. It weighs about 100 lb.
- Do the wiring. Turn the breaker off first. The cable from the indoor unit and the power from the home both connect at the outdoor unit. Match each wire to the diagram.
- Connect the copper lines. If you cut a line to fit, smooth the cut end and flare it. Start each flare nut by hand so it goes on straight. Then tighten it with a torque wrench to the number in the manual.
- Pressure test, then pull a vacuum. Test the lines with dry nitrogen. Then run a vacuum pump for at least 15 minutes, or down to 500 microns. Close it off and wait 5 minutes. The reading should hold.
- Open the valves and check for leaks. Open both valves all the way with a hex wrench. Check every joint with soapy water or a leak detector.
- Turn it on and test it. Run Cool, then Heat. MRCOOL says to test it for at least 30 minutes.
Tools the job takes
- Hammer drill and a 2.5 inch core drill
- Pipe cutter and reamer
- Flaring tool
- Torque wrench
- Vacuum pump
- Manifold gauge set and a micron gauge
- Hex (Allen) wrenches
- Leak detector or soapy water
- Level, tape measure and screwdrivers
Good to know first
- Power: the outdoor unit is wired to its own 208/230V circuit. Size the wire for at least 19 amps. The biggest breaker it can use is 20 amps.
- Line set: sold on its own in 16 ft, 25 ft or 50 ft lengths, 1/4 and 1/2 inch. The run has to be at least 9.84 ft and can go up to 98.4 ft. One unit can sit up to 65.6 ft higher than the other.
- Refrigerant: the outdoor unit comes filled with R-454B for up to 25 ft of line. A longer run needs 0.16 oz more for each extra foot.
- Not in the box: the line set, a longer drain hose, the power wire from the breaker panel, and a pad or wall bracket for the outdoor unit.
These steps follow MRCOOL's Olympus E Star installation manual (version date September 5, 2025). The full manual is under Manuals on this page. Want lines that hook up with two wrenches and no vacuum pump? See the MRCOOL DIY systems.
Day to day
Using the Olympus E Star
Controls
- Five modes: Auto, Cool, Heat, Dry and Fan.
- Follow Me: the remote reads the temperature where you are and tells the unit.
- Turbo: the strongest fan, to heat or cool the room fast.
- Silence and Sleep: run quieter and use less power at night.
- Timer: turn on or off in up to 24 hours.
Set up the phone app
- A Wi-Fi Smart Controller Kit comes in the box.
- Hook it to the indoor unit the way its sheet shows.
- Get the MRCOOL SmartHVAC app on your iPhone or Android phone.
- Follow the sheet to add your unit to your Wi-Fi.
- It also works with Alexa and Google Assistant.
Care
- Clean the filter every two weeks. Lift the front panel, pull the filter out, wash it in warm water with mild soap and let it air dry out of the sun.
- Active Clean: press Clean on the remote. The unit cleans itself and shuts off in 20 to 45 minutes.
- Auto restart: after a power outage it comes back on by itself.
Is a line set included?
No. It is sold on its own so you can pick the length. For this size, get the 16 ft, 25 ft or 50 ft Olympus line set. Each one comes with the wire that runs between the two units.
How do the lines hook up?
With flare nuts. Each nut is tightened with a torque wrench. Then a vacuum pump pulls the air out of the lines before the valves are opened.
What tools does the install take?
A hammer drill with a core drill, a pipe cutter and reamer, a flaring tool, a torque wrench, a vacuum pump, a manifold gauge set, a micron gauge, hex wrenches, and a leak detector or soapy water.
Does the outdoor unit come with refrigerant in it?
Yes. It comes filled with R-454B for up to 25 ft of line. A longer run needs 0.16 oz more for each extra foot.
What power does it need?
The outdoor unit is wired to its own 208/230V circuit. It does not plug into a wall outlet. Size the wire for at least 19 amps. The biggest breaker it can use is 20 amps.
Is it ENERGY STAR certified?
Yes. The Olympus E Star is ENERGY STAR certified. This size is rated 21.4 SEER2 and 11.0 HSPF2.
What size hole goes through the wall?
One hole, 2.5 inches wide. Tilt it down toward the outside so water drains out.
How high does the indoor unit go?
At least 6 ft above the floor, in a room with a ceiling at least 7.3 ft high.
Does it need a drain?
Yes. Water from the indoor unit runs out through a drain hose. The hose goes through the same wall hole as the lines and has to run downhill.
Can I run it from my phone?
Yes. A Wi-Fi Smart Controller Kit comes in the box. Once it is on your Wi-Fi, you can use the MRCOOL SmartHVAC app, Alexa or Google Assistant. The remote works too.
How often do I clean the filter?
Every two weeks. Lift the front panel, pull the filter out, wash it in warm water with mild soap and let it air dry out of the sun.
How heavy are the two units?
The indoor unit weighs about 27 lb and the outdoor unit about 100 lb.
How loud is the indoor unit?
MRCOOL lists it at 19.5 dB(A) on its quietest setting.
How is it different from the MRCOOL Advantage?
The Olympus E Star is rated 21.4 SEER2 at this size. The Advantage is rated 19.2. MRCOOL covers Olympus parts for 5 years and the compressor for 7 years. The Advantage comes with a 16 ft line set kit. With Olympus you pick your line set length. See the Advantage.
How is it different from the MRCOOL DIY 5th Gen?
The DIY 5th Gen comes with a 25 ft line set that is already filled with refrigerant and screws on with two wrenches. The Olympus E Star uses copper lines with flare nuts and a vacuum pump. See the DIY systems.


