Not what you were looking for? Find your system:
MRCOOL Olympus 4th Gen Multi-Zone Condensers
MRCOOL Olympus 27,000 BTU 4-Zone Outdoor Unit Only, 230V (Indoor Units Sold Separately) (MULTI4-27HP230C-O)
Model MULTI4-27HP230C-O
Outdoor unit only. It works with an Olympus multi-zone indoor unit.
See Olympus multi-zone unitsAlready have the indoor unit? Add this one to your cart below.
- Cooling26,600 BTU
- Efficiency25.0 SEER2
- Heating9.5 HSPF2
- Power208-240V
- RefrigerantR-454B
- Heats and cools up to 4 rooms from one outdoor unit
- 27,000 BTU total capacity, shared across the rooms
- Control it with the remote, your phone, Alexa or Google Assistant
Limited stock
Free shipping · Ships in 1–2 business days
Secure checkout through Shopify
- Authorized MRCOOL dealer
- Licensed HVAC contractor
- Free shipping
- 30-day returns
- Free cancellation before it ships
Authorized MRCOOL dealer. You get new, genuine MRCOOL equipment with the full MRCOOL warranty. A licensed HVAC pro answers your texts.
About usRun by a licensed HVAC contractor. Text our team your sizing or install questions, Monday to Friday, 8 AM to 5 PM Central.
About usThis ships free. Orders under $300 ship for $19.95. You get tracking by email when it ships.
Shipping details30-day returns. Ask within 30 days of delivery. Returns ship back by carrier from your home. Send it back unopened for a refund, minus a 15% restocking fee. If it arrives damaged, broken or wrong, there is no fee and we pay the return shipping.
Return policyFree cancellation. Cancel before your order ships and you pay nothing.
Return policy Questions? Text a licensed HVAC pro. (479) 488-3576 · Mon to Fri, 8 AM to 5 PM CentralProduct overview
About this unit
The MRCOOL Olympus 27,000 BTU 4-Zone Outdoor Unit Only, 230V (model MULTI4-27HP230C-O) is a multi-zone outdoor unit that runs up to 4 indoor units, so each room gets its own temperature control. It is sized for 27,000 BTU. Efficiency is 25.0 SEER2, 13.0 EER2 and 9.5 HSPF2.
Electrical
It runs on 208/230V power with a minimum circuit ampacity of 23 A and a maximum fuse or breaker of 25 A.
Size and connections
It measures 37.24 x 16.14 x 31.89 in (W x D x H) and weighs 138.89 lb.
Buying from Cool Air Depot
- Authorized MRCOOL dealerNew equipment with the full MRCOOL factory warranty.
- Free shippingThis item ships free.
- 30-day returnsRequest a return within 30 days of delivery, or cancel free before your order ships. Return policy
- Licensed HVAC supportText a pro at (479) 488-3576, Monday to Friday, 8 AM to 5 PM Central.
What's included
What's in the box
In the box
- Outdoor unitMULTI4-27HP230C-O
Not included: indoor units and line sets.
Specifications
Specs
Performance
| Maximum zones | 4 |
|---|---|
| SEER2, non-ducted | 25.0 |
| EER2, non-ducted | 13.0 |
| HSPF2-4, non-ducted | 9.5 |
| HSPF2-5 | 7.0 |
Electrical
| Power supply | 208/230V, 60Hz, 1Ph |
|---|---|
| MCA | 23 A |
| Maximum fuse | 25 A |
Dimensions
| Net W x D x H | 37.24 x 16.14 x 31.89 in |
|---|---|
| Packing W x D x H | 42.91 x 19.68 x 34.84 in |
| Net / gross weight | 138.89 / 149.69 lb |
Piping
| Maximum length for one indoor unit | 98 ft |
|---|---|
| Maximum total length all rooms | 262 ft |
| Maximum indoor to outdoor height difference | 49 ft |
| Maximum height between indoor units | 33 ft |
| Connecting pipe assembly | Add the line set length you need |
Figures come from MRCOOL's spec sheet, installation manual and AHRI certificate for this model. MRCOOL notes that spec sheet figures may change during production.
Warranty
MRCOOL's factory warranty
Covered
- Starts on your proof-of-purchase date. No registration is needed.
- Parts include the remote, the Wi-Fi dongle, pre-charged line sets and the parts inside the indoor and outdoor units (the compressor has its own 7-year term).
Warranty exclusions
- Labor, shipping and refrigerant costs
- Damage from an install that doesn't follow the manual, local codes or permits
- A unit moved from its first install address
Summary of MRCOOL's limited warranty for the Olympus series (rev. 05.12.25). The PDF below is the full terms. MRCOOL may ask for a licensed HVAC technician to diagnose a problem before approving a claim. Claims go to MRCOOL at (270) 366-0457 or support@mrcool.com.
Documents
Manuals and documents
Install and use
Specs and ratings
Warranty
For your installer
Check the ratings yourself: enter AHRI reference number 217291696, date 09-29-2025 and certificate number 134036482959601768 at ahridirectory.org.
FAQ
Questions people ask
Still have a question? A licensed HVAC pro answers texts Monday to Friday, 8 AM to 5 PM Central.
Text a pro: (479) 488-3576Who installs it?
A licensed HVAC technician. It's built for professional installation, so any local HVAC company can install it.
Which line set does it use?
It uses an Olympus flared line set in the matching pipe size, sold separately so you can pick your length.
What's the warranty?
MRCOOL covers parts for 5 years and the compressor for 7 years from your proof-of-purchase date, with no registration needed. See the warranty section above for details.
Pictures and video
See the MRCOOL Olympus outdoor unit up close
The Olympus line in 22 seconds
A short video from MRCOOL. One Olympus outdoor unit can run up to six indoor units. It comes with a 5 year parts and 7 year compressor warranty.
6 things to know






This is the outdoor unit by itself. Add up to 4 indoor units: see the Olympus ceiling cassettes and ducted units. Each indoor unit needs its own line set, in 16 ft, 25 ft or 50 ft lengths.
Pictures and video are from MRCOOL.
Installation
How an Olympus multi-zone system goes in
Olympus hooks up the classic way. The copper lines join with flare nuts. Then a vacuum pump clears the air out of the lines before the valves are opened. Here is the whole job, start to finish.
The install, step by step
- Set the outdoor unit. It needs a level pad or a wall bracket with room for air around it. Bolt it down with M10 bolts. It weighs about 139 lb.
- Put in each indoor unit. Follow the manual that comes with each one.
- Run a line set from each indoor unit. The biggest indoor unit goes on port A, the next biggest on port B, and so on.
- Do the wiring. Turn the breaker off first. The power from the home goes to the outdoor unit. A cable runs from each indoor unit to its own terminals on the outdoor unit.
- Connect the copper lines. If you cut a line to fit, smooth the cut end and flare it. Start each flare nut by hand so it goes on straight. Then tighten it with a torque wrench to the number in the manual. Adapters for the different pipe sizes come in the box.
- Pressure test, then pull a vacuum. Test the lines with dry nitrogen. Then run a vacuum pump for at least 15 minutes, or down to 500 microns. Close it off and wait 5 minutes. The reading should hold.
- Open the valves and check for leaks. Open the valves on the outdoor unit all the way with a hex wrench. Check every joint with soapy water or a leak detector.
- Run the built-in check. Hold the check switch on the outdoor unit for 5 seconds, until it shows CE. It checks the wiring and the piping in 5 to 10 minutes. It has to be above 41 degrees outside.
- Turn it on and test it. Run Cool, then Heat. MRCOOL says to test it for at least 30 minutes.
Tools the job takes
- Core drill for the hole in the outside wall
- Pipe cutter and reamer
- Flaring tool
- Torque wrench
- Vacuum pump
- Manifold gauge set and a micron gauge
- Hex (Allen) wrenches
- Leak detector or soapy water
- Level, tape measure and screwdrivers
Good to know first
- Power: the outdoor unit is wired to its own 208/230V circuit. Size the wire for at least 23 amps. The biggest breaker it can use is 25 amps.
- Line sets: one for each indoor unit, sold on their own in 16 ft, 25 ft or 50 ft lengths. Each run has to be at least 9.8 ft and can go up to 98 ft. All the runs together can add up to 262 ft.
- Height: the outdoor unit can sit up to 49 ft above or below the indoor units. The indoor units can be up to 33 ft apart in height.
- Refrigerant: the outdoor unit comes filled with R-454B for 24.6 ft of line to each indoor unit. Longer runs need more added.
- Not in the box: the indoor units, the line sets, the power wire from the breaker panel, and a pad or wall bracket.
These steps follow MRCOOL's Olympus installation manual for this unit. The full manual is under Manuals on this page. Want lines that hook up with two wrenches and no vacuum pump? See the MRCOOL DIY Multi Room Builder.
Day to day
Living with Olympus multi-zone
Controls
- Every indoor unit has its own remote.
- Set each room the way you like it.
- The outdoor unit speeds up and slows down to match what the rooms need.
Hot days and cold days
- Olympus multi-zone cools when it is up to 122 degrees outside.
- It heats when it is as cold as 13 below zero outside.
- One system does both the heating and the cooling.
Care
- Keep leaves, grass and snow away from the outdoor unit so air can move through it.
- Clean each indoor unit's filter the way its manual says.
How many rooms can it run?
Up to 4. Each room has its own indoor unit and its own remote.
Which indoor units does it work with?
Olympus ceiling cassettes and ducted units, 9,000 to 24,000 BTU. MRCOOL's manual also lists Olympus wall units. The biggest indoor unit goes on port A.
Are the indoor units included?
No. This is the outdoor unit by itself. Pick the indoor units and a line set for each one.
How long can the lines be?
Each run has to be at least 9.8 ft and can go up to 98 ft. All the runs together can add up to 262 ft.
What power does it need?
Its own 208/230V circuit. Size the wire for at least 23 amps. The biggest breaker it can use is 25 amps.
How cold can it be outside and still heat?
MRCOOL's manual lists heating down to 13 below zero (-13 F) and cooling up to 122 F.
Does it come with refrigerant in it?
Yes. It comes filled with R-454B for 24.6 ft of line to each indoor unit. Longer runs need more added.
How heavy is it?
About 139 lb.
Is a line set included?
No. Each indoor unit needs its own line set. They are sold on their own in 16 ft, 25 ft or 50 ft lengths.
How do the lines hook up?
With flare nuts. Each nut is tightened with a torque wrench. Then a vacuum pump pulls the air out of the lines before the valves are opened.
What tools does the install take?
A pipe cutter and reamer, a flaring tool, a torque wrench, a vacuum pump, a manifold gauge set, a micron gauge, hex wrenches, and a leak detector or soapy water.
How is it different from MRCOOL DIY multi-zone?
DIY multi-zone uses line sets that come filled with refrigerant and screw on with two wrenches. Olympus uses copper lines with flare nuts and a vacuum pump. See the DIY Multi Room Builder.