Not what you were looking for? Find your system:
MRCOOL Olympus Cassette
MRCOOL Olympus 24,000 BTU Ceiling Cassette with Panel, Indoor Unit Only, 230V (Outdoor Unit Sold Separately) (CASSETTE24HP-230C-P-O)
Model CASSETTE24HP-230C-P-O
Indoor unit only. It works with an Olympus multi-zone outdoor unit.
See Olympus multi-zone unitsAlready have the outdoor unit? Add this one to your cart below.
- Power208-240V
- RefrigerantR-454B
- 24,000 BTU heating and cooling
- Ductless: heats and cools one room with no ductwork to install
- Control it with the remote, your phone, Alexa or Google Assistant
- Pairs with the matching outdoor unit, or get both as a complete system
In stock
Free shipping · Ships in 1–2 business days
Secure checkout through Shopify
- Authorized MRCOOL dealer
- Licensed HVAC contractor
- Free shipping
- 30-day returns
- Free cancellation before it ships
Authorized MRCOOL dealer. You get new, genuine MRCOOL equipment with the full MRCOOL warranty. A licensed HVAC pro answers your texts.
About usRun by a licensed HVAC contractor. Text our team your sizing or install questions, Monday to Friday, 8 AM to 5 PM Central.
About usThis ships free. Orders under $300 ship for $19.95. You get tracking by email when it ships.
Shipping details30-day returns. Ask within 30 days of delivery. Returns ship back by carrier from your home. Send it back unopened for a refund, minus a 15% restocking fee. If it arrives damaged, broken or wrong, there is no fee and we pay the return shipping.
Return policyFree cancellation. Cancel before your order ships and you pay nothing.
Return policy Questions? Text a licensed HVAC pro. (479) 488-3576 · Mon to Fri, 8 AM to 5 PM CentralProduct overview
About this unit
The MRCOOL Olympus 24,000 BTU Ceiling Cassette with Panel (model CASSETTE24HP-230C-P-O) is a ceiling cassette indoor unit for a mini-split heat pump. It mounts in the ceiling, with only the grille panel showing in the room. It is sized for 24,000 BTU.
Airflow and electrical
It runs on 208/230V power with a minimum circuit ampacity of 3.0 A and a maximum fuse or breaker of 15 A.
Size and connections
It measures 32.68 x 32.68 x 8.07 in (W x D x H) and weighs 47.18 lb. Refrigerant connections: 3/8 / 5/8 in.
Buying from Cool Air Depot
- Authorized MRCOOL dealerNew equipment with the full MRCOOL factory warranty.
- Free shippingThis item ships free.
- 30-day returnsRequest a return within 30 days of delivery, or cancel free before your order ships. Return policy
- Licensed HVAC supportText a pro at (479) 488-3576, Monday to Friday, 8 AM to 5 PM Central.
What's included
What's in the box
In the box
- Indoor unitCASSETTE24HP-230C-P-O
Not included: the outdoor unit and the line set.
Specifications
Specs
Specs
| Power supply | 208/230V, 60Hz, 1Ph |
|---|---|
| Minimum circuit ampacity | 3.0 A |
| Maximum fuse | 15 A |
| Net W x D x H | 32.68 x 32.68 x 8.07 in |
| Net / gross weight | 47.18 / 59.08 lb |
| Liquid / gas pipe size | 3/8 / 5/8 in |
| Connecting pipe assembly | Add the line set length you need |
Figures come from MRCOOL's spec sheet, installation manual and AHRI certificate for this model. MRCOOL notes that spec sheet figures may change during production.
Warranty
MRCOOL's factory warranty
Covered
- Starts on your proof-of-purchase date. No registration is needed.
- Parts include the remote, the Wi-Fi dongle, pre-charged line sets and the parts inside the indoor and outdoor units (the compressor has its own 7-year term).
Warranty exclusions
- Labor, shipping and refrigerant costs
- Damage from an install that doesn't follow the manual, local codes or permits
- A unit moved from its first install address
Summary of MRCOOL's limited warranty for the Olympus series (rev. 05.12.25). The PDF below is the full terms. MRCOOL may ask for a licensed HVAC technician to diagnose a problem before approving a claim. Claims go to MRCOOL at (270) 366-0457 or support@mrcool.com.
Documents
Manuals and documents
Install and use
Specs and ratings
Warranty
For your installer
FAQ
Questions people ask
Still have a question? A licensed HVAC pro answers texts Monday to Friday, 8 AM to 5 PM Central.
Text a pro: (479) 488-3576Who installs it?
A licensed HVAC technician. It's built for professional installation, so any local HVAC company can install it.
Which line set does it use?
It uses an Olympus flared line set in the matching pipe size, sold separately so you can pick your length.
What's the warranty?
MRCOOL covers parts for 5 years and the compressor for 7 years from your proof-of-purchase date, with no registration needed. See the warranty section above for details.
Pictures and video
See the MRCOOL Olympus ceiling cassette up close
The Olympus line in 22 seconds
A short video from MRCOOL. One Olympus outdoor unit can run up to six indoor units. It comes with a 5 year parts and 7 year compressor warranty.
4 things to know




This is the indoor unit by itself. It needs an Olympus multi-zone outdoor unit. See the Olympus multi-zone outdoor units. The line set is sold on its own: 16 ft, 25 ft or 50 ft.
Pictures and video are from MRCOOL.
Installation
How the Olympus ceiling cassette goes in
Olympus hooks up the classic way. The copper lines join with flare nuts. Then a vacuum pump clears the air out of the lines before the valves are opened. Here is the whole job, start to finish.
The install, step by step
- Cut the ceiling opening. Use the paper template in the box. The unit is 32.68 by 32.68 inches and 8.07 inches tall.
- Hang it from four bolts. The hooks come in the box. Make it level. It weighs about 47 lb. Get a helper.
- Run the drain. A drain pump is built in. The drain pipe can rise up to 29.5 inches near the unit. Then it slopes down the rest of the way.
- Do the wiring. Turn the breaker off first. A cable runs between this unit and the outdoor unit. Match each wire to the diagram.
- Connect the copper lines. If you cut a line to fit, smooth the cut end and flare it. Start each flare nut by hand so it goes on straight. Then tighten it with a torque wrench to the number in the manual.
- Pressure test, then pull a vacuum. Test the lines with dry nitrogen. Then run a vacuum pump for at least 15 minutes, or down to 500 microns. Close it off and wait 5 minutes. The reading should hold.
- Open the valves and check for leaks. Open the valves on the outdoor unit all the way with a hex wrench. Check every joint with soapy water or a leak detector.
- Test the drain. Pour about 2 quarts of water into the drain pan and run Cool. The water should run out. Then clip the panel on.
- Turn it on and test it. Run Cool, then Heat. MRCOOL says to test it for at least 30 minutes.
Tools the job takes
- Drywall saw, drill and a ladder
- Core drill for the hole in the outside wall
- Pipe cutter and reamer
- Flaring tool
- Torque wrench
- Vacuum pump
- Manifold gauge set and a micron gauge
- Hex (Allen) wrenches
- Leak detector or soapy water
- Level, tape measure and screwdrivers
Good to know first
- Outdoor unit: this indoor unit needs an Olympus outdoor unit. It is sold on its own.
- Line set: sold on its own in 16 ft, 25 ft or 50 ft lengths, 3/8 and 5/8 inch.
- Room above the ceiling: the unit is 32.68 by 32.68 inches and 8.07 inches tall.
- Drain: plan where the water will go before you cut the ceiling.
- Not in the box: the line set, the drain pipe and the cable to the outdoor unit.
These steps follow MRCOOL's Olympus installation manual for this unit. The full manual is under Manuals on this page. Want lines that hook up with two wrenches and no vacuum pump? See the MRCOOL DIY Multi Room Builder.
Day to day
Living with Olympus multi-zone
Controls
- Five modes: Auto, Cool, Heat, Dry and Fan.
- Follow Me: the remote reads the temperature where you are and tells the unit.
- Breeze Away: points the air away from you.
- Turbo: the strongest fan, to heat or cool the room fast.
- Timer: turn on or off in up to 24 hours.
Hot days and cold days
- Olympus multi-zone cools when it is up to 122 degrees outside.
- It heats when it is as cold as 13 below zero outside.
- One system does both the heating and the cooling.
Care
- Clean the filter every two weeks.
- Press the two tabs on the grille, swing it down and lift the filter out.
- Wash it in warm water with mild soap and let it air dry.
Which outdoor units does it work with?
The Olympus multi-zone outdoor units: 18,000, 27,000, 36,000 and 48,000 BTU.
How big a room will it handle?
MRCOOL rates it for up to 1,050 sq ft.
How much room does it need above the ceiling?
The unit is 32.68 by 32.68 inches and 8.07 inches tall.
Does it need a drain?
Yes. A drain pump is built in. The drain pipe can rise up to 29.5 inches near the unit, then it slopes down.
Does it come with a remote?
Yes. The remote and the panel come with it.
How heavy is it?
About 47 lb. Get a helper for the lift.
How do the lines hook up?
With flare nuts. Each nut is tightened with a torque wrench. Then a vacuum pump pulls the air out of the lines before the valves are opened.
What tools does the install take?
A pipe cutter and reamer, a flaring tool, a torque wrench, a vacuum pump, a manifold gauge set, a micron gauge, hex wrenches, and a leak detector or soapy water.
How is it different from MRCOOL DIY multi-zone?
DIY multi-zone uses line sets that come filled with refrigerant and screw on with two wrenches. Olympus uses copper lines with flare nuts and a vacuum pump. See the DIY Multi Room Builder.