Not what you were looking for? Find your system:
MRCOOL Olympus Duct
MRCOOL Olympus 18,000 BTU Ducted Air Handler, Indoor Unit Only, 230V (Outdoor Unit Sold Separately) (DUCT-18HP-230B-O)
Model DUCT-18HP-230B-O
Indoor unit only. It works with an Olympus multi-zone outdoor unit.
See Olympus multi-zone unitsAlready have the outdoor unit? Add this one to your cart below.
- Power208-240V
- RefrigerantR-454B
- 18,000 BTU ducted mini-split air handler for heating and cooling
- Hides out of sight and sends air through short duct runs
- Part of MRCOOL's contractor-grade Olympus line
- Pairs with the matching Olympus outdoor unit
Limited stock
Free shipping · Ships in 1–2 business days
Secure checkout through Shopify
- Authorized MRCOOL dealer
- Licensed HVAC contractor
- Free shipping
- 30-day returns
- Free cancellation before it ships
Authorized MRCOOL dealer. You get new, genuine MRCOOL equipment with the full MRCOOL warranty. A licensed HVAC pro answers your texts.
About usRun by a licensed HVAC contractor. Text our team your sizing or install questions, Monday to Friday, 8 AM to 5 PM Central.
About usThis ships free. Orders under $300 ship for $19.95. You get tracking by email when it ships.
Shipping details30-day returns. Ask within 30 days of delivery. Returns ship back by carrier from your home. Send it back unopened for a refund, minus a 15% restocking fee. If it arrives damaged, broken or wrong, there is no fee and we pay the return shipping.
Return policyFree cancellation. Cancel before your order ships and you pay nothing.
Return policy Questions? Text a licensed HVAC pro. (479) 488-3576 · Mon to Fri, 8 AM to 5 PM CentralProduct overview
About this unit
The MRCOOL Olympus 18,000 BTU Ducted Air Handler (model DUCT-18HP-230B-O) is a concealed ducted indoor unit for a mini-split heat pump. It hides above the ceiling or in a closet and moves air through short duct runs. It is sized for 18,000 BTU.
Airflow and electrical
It runs on 208/230V power with a minimum circuit ampacity of 3.0 A and a maximum fuse or breaker of 15 A.
Size and connections
It measures 34.65 x 26.54 x 8.27 in (W x D x H) and weighs 54.45 lb. Refrigerant connections: 1/4 / 1/2 in.
Buying from Cool Air Depot
- Authorized MRCOOL dealerNew equipment with the full MRCOOL factory warranty.
- Free shippingThis item ships free.
- 30-day returnsRequest a return within 30 days of delivery, or cancel free before your order ships. Return policy
- Licensed HVAC supportText a pro at (479) 488-3576, Monday to Friday, 8 AM to 5 PM Central.
What's included
What's in the box
In the box
- Indoor unitDUCT-18HP-230B-O
Not included: the outdoor unit and the line set.
Specifications
Specs
Specs
| Power supply | 208/230V, 60Hz, 1Ph |
|---|---|
| Minimum circuit ampacity | 3.0 A |
| Maximum fuse | 15 A |
| Net W x D x H | 34.65 x 26.54 x 8.27 in |
| Net / gross weight | 54.45 / 66.14 lb |
| Liquid / gas pipe size | 1/4 / 1/2 in |
| Connecting pipe assembly | Add the line set length you need |
Figures come from MRCOOL's spec sheet, installation manual and AHRI certificate for this model. MRCOOL notes that spec sheet figures may change during production.
Warranty
MRCOOL's factory warranty
Covered
- Starts on your proof-of-purchase date. No registration is needed.
- Parts include the remote, the Wi-Fi dongle, pre-charged line sets and the parts inside the indoor and outdoor units (the compressor has its own 7-year term).
Warranty exclusions
- Labor, shipping and refrigerant costs
- Damage from an install that doesn't follow the manual, local codes or permits
- A unit moved from its first install address
Summary of MRCOOL's limited warranty for the Olympus series (rev. 05.12.25). The PDF below is the full terms. MRCOOL may ask for a licensed HVAC technician to diagnose a problem before approving a claim. Claims go to MRCOOL at (270) 366-0457 or support@mrcool.com.
Documents
Manuals and documents
Install and use
Specs and ratings
Warranty
For your installer
FAQ
Questions people ask
Still have a question? A licensed HVAC pro answers texts Monday to Friday, 8 AM to 5 PM Central.
Text a pro: (479) 488-3576Who installs it?
A licensed HVAC technician. It's built for professional installation, so any local HVAC company can install it.
Which line set does it use?
It uses an Olympus flared line set in the matching pipe size, sold separately so you can pick your length.
What's the warranty?
MRCOOL covers parts for 5 years and the compressor for 7 years from your proof-of-purchase date, with no registration needed. See the warranty section above for details.
Pictures and video
See the MRCOOL Olympus ducted unit up close
The Olympus line in 22 seconds
A short video from MRCOOL. One Olympus outdoor unit can run up to six indoor units. It comes with a 5 year parts and 7 year compressor warranty.
4 things to know




This is the indoor unit by itself. It needs an Olympus outdoor unit. For more than one room, see the Olympus multi-zone outdoor units. For one room, it pairs with the 18,000 BTU Olympus E Star outdoor unit. The line set is sold on its own: 16 ft, 25 ft or 50 ft.
Pictures and video are from MRCOOL.
Installation
How the Olympus ducted unit goes in
Olympus hooks up the classic way. The copper lines join with flare nuts. Then a vacuum pump clears the air out of the lines before the valves are opened. Here is the whole job, start to finish.
The install, step by step
- Pick the spot above the ceiling. The ceiling has to be flat and strong enough to hold about 54 lb. The unit is 8.27 inches tall.
- Hang it from four bolts. Make it level, with a slight tilt toward the drain. Get a helper.
- Hook up the ducts. Use at least 3.3 ft of duct on the inlet side, with a grille. Wrap the ducts with insulation.
- Run the drain. Put a trap in the drain pipe close to the unit. The pipe slopes down the rest of the way.
- Do the wiring. Turn the breaker off first. A cable runs between this unit and the outdoor unit. Match each wire to the diagram.
- Connect the copper lines. If you cut a line to fit, smooth the cut end and flare it. Start each flare nut by hand so it goes on straight. Then tighten it with a torque wrench to the number in the manual.
- Pressure test, then pull a vacuum. Test the lines with dry nitrogen. Then run a vacuum pump for at least 15 minutes, or down to 500 microns. Close it off and wait 5 minutes. The reading should hold.
- Open the valves and check for leaks. Open the valves on the outdoor unit all the way with a hex wrench. Check every joint with soapy water or a leak detector.
- Test the drain. Pour about 2 quarts of water into the drain pan and run Cool. The water should run out.
- Turn it on and test it. Run Cool, then Heat. MRCOOL says to test it for at least 30 minutes.
Tools the job takes
- Drywall saw, drill and a ladder
- Core drill for the hole in the outside wall
- Pipe cutter and reamer
- Flaring tool
- Torque wrench
- Vacuum pump
- Manifold gauge set and a micron gauge
- Hex (Allen) wrenches
- Leak detector or soapy water
- Level, tape measure and screwdrivers
Good to know first
- Outdoor unit: this indoor unit needs an Olympus outdoor unit. It is sold on its own.
- Line set: sold on its own in 16 ft, 25 ft or 50 ft lengths, 1/4 and 1/2 inch.
- Room above the ceiling: the unit is 8.27 inches tall, plus room for the ducts and the drain.
- Drain: plan where the water will go before you cut the ceiling.
- Not in the box: the line set, the drain pipe and the cable to the outdoor unit. The ducts, the grilles and a filter are not in the box either.
These steps follow MRCOOL's Olympus installation manual for this unit. The full manual is under Manuals on this page. Want lines that hook up with two wrenches and no vacuum pump? See the MRCOOL DIY Multi Room Builder.
Day to day
Living with Olympus multi-zone
Controls
- A remote and a wired wall thermostat both come with it.
- Set the mode, the temperature and the fan speed.
- A small display panel comes with it too.
Hot days and cold days
- Olympus multi-zone cools when it is up to 122 degrees outside.
- It heats when it is as cold as 13 below zero outside.
- One system does both the heating and the cooling.
Care
- Keep the return grille and the vents clear so air can move.
- If you fit a filter in the return, check it often.
- Keep leaves and snow away from the outdoor unit.
Which outdoor units does it work with?
The Olympus multi-zone outdoor units, and the 18,000 BTU Olympus E Star outdoor unit for one room.
How big a room will it handle?
MRCOOL rates it for up to 800 sq ft.
How much room does it need above the ceiling?
The unit is 8.27 inches tall. Leave room for the ducts and the drain too.
Does it need a drain?
Yes. The drain pipe needs a trap close to the unit and has to slope down.
Does it come with a remote?
Yes. A remote and a wired wall thermostat both come with it.
How heavy is it?
About 54 lb. Get a helper for the lift.
How do the lines hook up?
With flare nuts. Each nut is tightened with a torque wrench. Then a vacuum pump pulls the air out of the lines before the valves are opened.
What tools does the install take?
A pipe cutter and reamer, a flaring tool, a torque wrench, a vacuum pump, a manifold gauge set, a micron gauge, hex wrenches, and a leak detector or soapy water.
How is it different from MRCOOL DIY multi-zone?
DIY multi-zone uses line sets that come filled with refrigerant and screw on with two wrenches. Olympus uses copper lines with flare nuts and a vacuum pump. See the DIY Multi Room Builder.