Not what you were looking for? Find your system:
MRCOOL Hyper Heat Dual Fuel
MRCOOL Hyper Heat 2.5 Ton Dual Fuel System: Heat Pump + 80,000 BTU 80% AFUE Gas Furnace + Cased Coil
Models: CENTRAL-30-HP-C-230B00-O + MCMP3036BOTB + MGA80SE080B4C
- Size2.5 Ton
- Cooling29,000 BTU
- Gas furnace80K BTU
- Furnace AFUE80%
- Heat pump down to-22°F
- 2.5 Ton heat pump with a 80,000 BTU 80% AFUE gas furnace
- AHRI certified match 218029410: 14.5 SEER2 and 8.5 HSPF2
- The heat pump keeps heating to 22°F below zero. Gas heat covers the coldest days.
- Furnace and coil are both 17.5 in wide. Installs upflow, downflow or horizontal.
- Pre-charged R-454B cased coil with a TXV and a refrigerant leak sensor
Includes the heat pump, gas furnace and cased coil. Line set, flange and thermostat are sold separately.
In stock
Free shipping · Ships in 1–2 business days
Secure checkout through Shopify
- Authorized MRCOOL dealer
- Licensed HVAC contractor
- Free shipping
- 30-day returns
- Free cancellation before it ships
Authorized MRCOOL dealer. You get new, genuine MRCOOL equipment with the full MRCOOL warranty. A licensed HVAC pro answers your texts.
About usRun by a licensed HVAC contractor. Text our team your sizing or install questions, Monday to Friday, 8 AM to 5 PM Central.
About usThis ships free. Orders under $300 ship for $19.95. You get tracking by email when it ships.
Shipping details30-day returns. Ask within 30 days of delivery. Returns ship back by carrier from your home. Send it back unopened for a refund, minus a 15% restocking fee. If it arrives damaged, broken or wrong, there is no fee and we pay the return shipping.
Return policyFree cancellation. Cancel before your order ships and you pay nothing.
Return policyAdd to your orderChecked to fit this system
-
MRCOOL 1.5-3 Ton 17.5" Cased Coil Flange for Furnace Install (MCMP1836B-F) Flange that fits this 17.5 in coil to the furnace.$40.00
Product overview
About this system
This MRCOOL Hyper Heat 2.5 Ton dual fuel system combines a cold-climate heat pump with a 80,000 BTU, 80% AFUE gas furnace and a matched cased coil. The heat pump handles cooling in summer and provides efficient electric heat through most of the winter. When outdoor temperatures drop further, the gas furnace takes over to keep the home comfortable.
AHRI-certified performance
The heat pump, furnace and coil are an AHRI-certified match (reference 218029410), rated 14.5 SEER2 and 8.5 HSPF2. Because the three components are rated together, the efficiency ratings on this page apply to this exact combination. The heat pump keeps heating down to -22°F.
Furnace and coil
The furnace and coil are both 17.5 in wide and install upflow, downflow or horizontal. The cased coil ships pre-charged with R-454B refrigerant and includes a TXV and a refrigerant leak sensor.
Buying from Cool Air Depot
- Authorized MRCOOL dealerNew equipment with the full MRCOOL factory warranty.
- Free shippingThis item ships free.
- 30-day returnsRequest a return within 30 days of delivery, or cancel free before your order ships. Return policy
- Licensed HVAC supportText a pro at (479) 488-3576, Monday to Friday, 8 AM to 5 PM Central.
What's included
What's in the box
In the box
- Hyper Heat heat pumpOne MRCOOL Hyper Heat 2.5 Ton heat pump condenser (CENTRAL-30-HP-C-230B00-O). It heats and cools.
- Gas furnaceOne MRCOOL VersaPro 80K BTU 80% AFUE single-stage gas furnace (MGA80SE080B4C), 17.5 in wide.
- Cased coilOne MRCOOL 2.5-3 Ton 17.5 in cased A-coil (MCMP3036BOTB), pre-charged with R-454B.
- ManualsEach part comes in its own box with its own manual.
Specifications
Specs for this dual fuel system
AHRI certified system
| AHRI reference number | 218029410 |
|---|---|
| Outdoor unit + coil + furnace | CENTRAL-30-HP-C-230B00-O + MCMP3036BOTB + MGA80SE080B4C |
| Cooling capacity | 29,000 BTU/h |
| SEER2 | 14.5 |
| EER2 | 10.4 |
| Heat pump heating at 47°F | 29,000 BTU/h |
| HSPF2 (Region IV) | 8.5 |
| Furnace AFUE | 80% |
Heat pump (outdoor unit)
| Model | CENTRAL-30-HP-C-230B00-O |
|---|---|
| Series | MRCOOL Central Ducted Hyper Heat |
| Size | 2.5 Ton |
| Power supply | 208/230V, 60 Hz, 1 phase |
| Minimum circuit ampacity | 29.5 A |
| Maximum fuse or breaker | 30 A |
| Refrigerant | R-454B |
| Factory charge | 105.82 oz |
| Line sizes | 3/8 in liquid, 3/4 in suction |
| Sound level | 60.5 dB(A) |
| Size, W x D x H | 37.24 x 16.14 x 31.89 in |
| Weight | 164.02 lb (174.6 lb boxed) |
Gas furnace
| Model | MGA80SE080B4C |
|---|---|
| Input | 80,000 BTU/h |
| Output | 64,000 BTU/h |
| AFUE | 80% |
| Gas valve | Single stage |
| Positions | Upflow, downflow or horizontal |
| Blower | 1/2 HP, 5 speed ECM |
| Most airflow at 0.5 in ESP | 1300 CFM |
| Temperature rise | 30-60°F |
| Power supply | 115V, 60 Hz, 1 phase |
| Minimum circuit ampacity | 8 A |
| Maximum fuse or breaker | 15 A |
| Gas connection | 3/4 in |
| Fuel | Natural gas (propane with MRCOOL's LP conversion kit) |
| Cabinet, W x D x H | 17.5 x 28.75 x 33.75 in |
| Weight | 128 lb (155 lb boxed) |
Cased coil
| Model | MCMP3036BOTB |
|---|---|
| Size | 2.5-3 Ton |
| Coil type | A-coil, cased, multi-position |
| Metering | TXV, factory installed |
| Refrigerant | R-454B, pre-charged |
| Leak sensor | A2L refrigerant leak sensor |
| Line sizes | 3/8 in liquid, 3/4 in suction |
| Power supply | 24V |
| Size, W x D x H | 17.5 x 21 x 23.5 in |
| Weight | 59.5 lb (68 lb boxed) |
Shipping
| Boxes | 3 (heat pump, furnace, coil) |
|---|---|
| Total shipping weight | 397.6 lb |
| Not included | Line set, coil flange, thermostat, filter, gas venting |
System ratings come from AHRI certificate 134393633726606135 for reference number 218029410, dated 11/16/2026. Part figures come from MRCOOL's spec sheets and manuals for CENTRAL-30-HP-C-230B00-O, MGA80SE080B4C and MCMP3036BOTB (see Manuals below).
Installation
How the system goes in
- 1Set the outdoor unit
On a level pad with the clearances in the heat pump manual.
- 2Set the furnace
In an upflow, downflow or horizontal position, with ducts, gas and venting to the furnace manual and local code.
- 3Set the coil on the furnace
The 17.5 in coil matches the 17.5 in furnace. The MRCOOL flange (sold separately) gives it a clean, sealed fit.
- 4Connect the line set
3/8 in and 3/4 in lines. A MRCOOL No-Vac pre-charged line set connects without vacuuming.
- 5Wire it
Heat pump on 208/230V, furnace on 115V, and a dual fuel thermostat to run both.
- 6Start up
Run the startup checks in each manual.
Power and tools
Electrical
- Heat pump
- 208/230V, 1 phase. 29.5 A minimum circuit, 30 A max breaker.
- Furnace
- 115V, 1 phase. 15 A max breaker.
- Thermostat
- 24V dual fuel thermostat (heat pump plus gas heat).
Warranty
MRCOOL's factory warranty
Covered
- Each part has its own MRCOOL limited warranty for the original owner.
- Register the furnace with MRCOOL within 90 days of purchase for 10 years on parts and a lifetime heat exchanger.
- The heat pump labor coverage starts on day 91 after purchase.
Warranty exclusions
- Shipping and refrigerant costs
- Damage from faulty installation
- A unit moved from its first install address
Summary of MRCOOL's limited warranties for the heat pump, furnace and coil. Read each one under Manuals.
Documents
Manuals and documents
Install and use
Specs and ratings
Check the ratings yourself: enter AHRI reference number 218029410, date 11-16-2026 and certificate number 134393633726606135 at ahridirectory.org.
FAQ
Questions people ask
Still have a question? A licensed HVAC pro answers texts Monday to Friday, 8 AM to 5 PM Central.
Text a pro: (479) 488-3576What is a dual fuel system?
It pairs an electric heat pump with a gas furnace. The heat pump cools in summer and heats on most winter days. When it gets very cold, the thermostat switches to the gas furnace.
What comes in this system?
Three parts, each in its own box: the Hyper Heat 2.5 Ton heat pump (CENTRAL-30-HP-C-230B00-O), the 80K BTU 80% AFUE gas furnace (MGA80SE080B4C) and the 17.5 in cased coil (MCMP3036BOTB).
Do I need a special thermostat?
Yes. It needs a dual fuel thermostat that can run a heat pump and a gas furnace. The MRCOOL Smart WiFi Thermostat supports dual fuel, and you can add it with the system.
Which line set does it use?
The heat pump and coil use 3/8 in and 3/4 in lines. MRCOOL No-Vac pre-charged line sets come in 15, 25, 35 and 50 ft lengths and connect without vacuuming.
What is the flange for?
It fits the cased coil to the top of the furnace for a clean, sealed fit. It is sold separately, so you only buy it if you need it.
Is this an AHRI matched system?
Yes. AHRI reference 218029410 rates this heat pump, coil and furnace together at 14.5 SEER2, 10.4 EER2 and 8.5 HSPF2.
Can it run on propane?
It is set up for natural gas. MRCOOL sells an LP conversion kit for propane.
Which ways can the furnace be installed?
This 80% furnace installs upflow, downflow or horizontal. The cased coil is multi-position too.
What size do I need?
A 2.5 Ton system fits many homes, but the right size depends on your house. A load calculation tells you for sure. Text a pro and we will help you check.
What is the warranty?
Each part has its own MRCOOL limited warranty. See the Warranty section and the warranty papers under Manuals.
Pictures and video
See the MRCOOL Hyper Heat dual fuel system up close
The three parts



Other Hyper Heat dual fuel sizes and furnaces
Same heat pump series, matched by AHRI to a different size or furnace. The furnace size is its input.
Best for: Homes with gas and cold winters. The heat pump runs most days and gas heat takes the coldest ones.
Add a pre-charged line setOptional, sold separately