Not what you were looking for? Find your system:







MRCOOL Easy Pro 5th Gen
MRCOOL Easy Pro 5th Gen 12,000 BTU Mini-Split Indoor Air Handler, 115V (EZPRO-12-HP-WMAH-115D-O)
Model EZPRO-12-HP-WMAH-115D-O
Indoor unit only. It needs the matching outdoor unit to heat and cool. Most people get both together.
Get the complete system: indoor + outdoor$1,649Already have the outdoor unit? Add this one to your cart below.
- Capacity12,000 BTU
- Power120V
- Sound17.5 dB(A)
- Weight24.91 lb
- Width31.57 in
- Made for do-it-yourself installation with MRCOOL's pre-charged Quick Connect line sets
- 12,000 BTU heating and cooling for up to 550 sq ft
- Ductless: heats and cools one room with no ductwork to install
- 19.5 SEER2 efficiency to keep power bills down
- Pairs with the matching outdoor unit, or get both as a complete system
In stock
Free shipping · Ships in 1–2 business days
Secure checkout through Shopify
- Authorized MRCOOL dealer
- Licensed HVAC contractor
- Free shipping
- 30-day returns
- Free cancellation before it ships
Authorized MRCOOL dealer. You get new, genuine MRCOOL equipment with the full MRCOOL warranty. A licensed HVAC pro answers your texts.
About usRun by a licensed HVAC contractor. Text our team your sizing or install questions, Monday to Friday, 8 AM to 5 PM Central.
About usThis ships free. Orders under $300 ship for $19.95. You get tracking by email when it ships.
Shipping details30-day returns. Ask within 30 days of delivery. Returns ship back by carrier from your home. Send it back unopened for a refund, minus a 15% restocking fee. If it arrives damaged, broken or wrong, there is no fee and we pay the return shipping.
Return policyFree cancellation. Cancel before your order ships and you pay nothing.
Return policyAdd to your orderChecked to fit this unit
-
MRCOOL DIY 5th Gen 25 ft Line Set 1/4 x 3/8 in with DIY Pro Cable, R-454B (for 6K, 9K and 12K Indoor Units) (DIY25-1438C-O) 25 ft with DIY Pro Cable. Same R-454B refrigerant and 1/4 x 3/8 in line size as this unit.$409.00
-
MRCOOL DIY 5th Gen 35 ft Line Set 1/4 x 3/8 in with DIY Pro Cable, R-454B (for 6K, 9K and 12K Indoor Units) (DIY35-1438C-O) 35 ft with DIY Pro Cable. Same R-454B refrigerant and 1/4 x 3/8 in line size as this unit.$502.00
-
MRCOOL DIY 5th Gen 50 ft Line Set 1/4 x 3/8 in with DIY Pro Cable, R-454B (for 6K, 9K and 12K Indoor Units) (DIY50-1438C-O) 50 ft with DIY Pro Cable. Same R-454B refrigerant and 1/4 x 3/8 in line size as this unit.$587.00
-
MRCOOL LineGuard 4.5 in Line Set Cover Kit, 12 ft, White (MLG450) 12 ft cover that hides the line set, cable and drain on the outside wall. White.$132.00
-
MRCOOL LineGuard 4.5 in Line Set Cover Kit, 12 ft, Gray (MLG450-G-01) 12 ft cover that hides the line set, cable and drain on the outside wall. Gray.$133.00
-
MRCOOL LineGuard 4.5 in Line Set Cover Kit, 12 ft, Tan (MLG450-T-01) 12 ft cover that hides the line set, cable and drain on the outside wall. Tan.$133.00
-
MRCOOL Smart Wi-Fi Mini-Stat for Ductless Mini-Splits (MST05) Wall-mounted smart control for MRCOOL ductless units.$114.00
This is the indoor unit with its DIYPRO cable, remote and install kit. It pairs with the EZPRO-12-HP-C-11516D-O outdoor unit. Want both? Get the complete 12K system.
Questions? Text a licensed HVAC pro. (479) 488-3576 · Mon to Fri, 8 AM to 5 PM CentralProduct overview
About this unit
The MRCOOL Easy Pro 5th Gen 12,000 BTU indoor unit (model EZPRO-12-HP-WMAH-115D-O) is a wall-mounted air handler for one room or open area of up to 550 sq ft. It runs on 115V power and is sold without an outdoor unit. Paired with the matching Easy Pro 5th Gen 12,000 BTU outdoor unit (model EZPRO-12-HP-C-11516D-O), the system is rated 19.5 SEER2 and 9.3 HSPF2.
What you need to complete the system
Add the matching outdoor unit, model EZPRO-12-HP-C-11516D-O. It ships with a 16 ft line set that is pre-charged with R-454B refrigerant and fitted with Quick Connect couplings.
Features
The indoor unit runs as quietly as 17.5 dB(A) on its lowest fan setting. It comes with a remote control and a Smart Controller Kit for control from your phone over Wi-Fi.
Buying from Cool Air Depot
- Authorized MRCOOL dealerNew equipment with the full MRCOOL factory warranty.
- Free shippingThis item ships free.
- 30-day returnsRequest a return within 30 days of delivery, or cancel free before your order ships. Return policy
- Licensed HVAC supportText a pro at (479) 488-3576, Monday to Friday, 8 AM to 5 PM Central.
What's included
What's in the box
In the box
- Wall-mounted indoor unitEZPRO-12-HP-WMAH-115D-O, with mounting plate, paper template, remote control and holder
- DIYPRO cableConnects the indoor unit to the outdoor unit
- Smart Controller KitFor control from a smartphone app
- Wall sleeve, drain pipe and insulationPlastic wall sleeve and cap, drain pipe, 2 insulation sleeves and tape
Not included: the outdoor unit (EZPRO-12-HP-C-11516D-O). The outdoor unit ships with the 16 ft line set.
Full packing list from MRCOOL's manual
| Part | Qty |
|---|---|
| Manuals (installation and remote) | 2 |
| AAA batteries | 2 |
| Mounting plate (metal) and cardboard template | 1 each |
| Remote control | 1 |
| Remote control holder | 1 |
| Screws for the remote control holder | 2 |
| Drain pipe | 1 |
| Insulation sleeves | 2 |
| Anchors and mounting plate screws | 5 to 8 each |
| Sound-absorbent pads | 2 |
| Seal | 1 |
| Smart Controller Kit | 1 |
| Drain joint | 1 |
| DIYPRO cable | 1 |
| Plastic wall sleeve and cap | 1 |
| Small filters | 1 to 2 |
| Allen wrench | 1 |
| Neoprene | 1 |
| Non-adhesive tape | 1 |
MRCOOL notes that the manual's drawings are for reference and the parts may look a little different.
Specifications
Specs for this indoor unit
- SystemEZPRO-12-HP-11516D-O
- Indoor unitEZPRO-12-HP-WMAH-115D-O
- Outdoor unitEZPRO-12-HP-C-11516D-O
Indoor unit
| Model | EZPRO-12-HP-WMAH-115D-O |
|---|---|
| Size (W x D x H) | 31.57 x 7.87 x 11.61 in |
| Weight (unit / boxed) | 24.91 / 35.71 lb |
| Box size (W x D x H) | 36.02 x 17.95 x 14.17 in |
| Sound (turbo / high / medium / low / silent) | 44.5 / 40 / 35 / 25.5 / 17.5 dB(A) |
| Type | Wall-mounted |
Electrical
| Power supply | 115V, 1-phase, 60 Hz |
|---|---|
| Minimum circuit ampacity | 3.0 A |
| Maximum breaker or fuse | 15 A |
Connections
| Pipe sizes (liquid / gas) | 1/4 in / 3/8 in, Quick Connect |
|---|---|
| Refrigerant | R-454B |
| DIYPRO cable | Included |
Paired with EZPRO-12-HP-C-11516D-O
| Cooling capacity (at 95°F) | 12,000 BTU/h |
|---|---|
| Heating capacity (at 47°F) | 12,000 BTU/h |
| SEER2 | 19.5 |
| EER2 | 9.0 |
| HSPF2 (Region IV) | 9.3 |
| Room size, ideal conditions | Up to 550 sq ft |
Installation
| Indoor unit height | At least 6.0 ft above the floor |
|---|---|
| Ceiling height | At least 7.3 ft |
| Minimum room area (R-454B) | 12 sq ft |
| Wall hole | 2.5 in |
Paired ratings are from AHRI certificate 216032554 for this indoor unit with the EZPRO-12-HP-C-11516D-O outdoor unit. Other figures come from MRCOOL's Easy Pro 5th Gen spec sheet (V.03.05.2026) and installation manual. MRCOOL notes that spec sheet figures are preliminary and may change during production.
Installation
How a DIY install works
- 1Pick the spot
Mount the indoor unit at least 6 ft above the floor, in a room with a ceiling of at least 7.3 ft and at least 12 sq ft of floor area. Leave the clearances the manual shows.
- 2Mount the plate and drill the hole
Use the paper template, fix the metal mounting plate level on the wall and drill a 2.5 in hole for the line set, cable and drain, angled slightly down toward the outside.
- 3Hang the unit and run the drain
Hang the indoor unit on the mounting plate and route the drain pipe through the wall hole so water runs to the outside.
- 4Connect the line set
Thread each Quick Connect fitting by hand, then tighten it with two wrenches. There's no vacuuming and no refrigerant to add. Check every joint with leak-detection spray or soapy water.
Power and tools
Electrical
- Power supply
- 115V, 1-phase, 60 Hz
- Indoor unit, minimum circuit ampacity
- 3.0 A
- Indoor unit, maximum breaker or fuse
- 15 A
- DIYPRO cable
- Included with this indoor unit
Tools you'll need
- Drill and 2.5 in core drill for the wall hole
- Open-end wrenches: 19 mm, 22 or 24 mm, and 24 or 27 mm, or two adjustable wrenches (an HVAC torque wrench is best if you have one)
- Level and a Phillips screwdriver
- Leak-detection spray or soapy water
- Gloves, eye protection and a dust mask
Warranty
MRCOOL's factory warranty
Covered
- Starts on your proof-of-purchase date. No registration is needed.
- Parts include the compressor, coils, indoor and outdoor fan motors, blower wheels, fan blades, circuit boards, controllers and sensors.
- Repaired or replaced parts are covered for the rest of the original term.
Warranty exclusions
- Labor, shipping and refrigerant costs
- Damage from an install that doesn't follow the manual, local codes, permits or licensing
- A unit moved from its first install address, or installed outside the USA and Canada. The warranty doesn't transfer to a new owner.
Summary of MRCOOL's limited warranty for the Easy Pro 5th Gen models (rev. 06.17.26). The PDF below is the full terms. MRCOOL may ask for a licensed HVAC technician to diagnose a problem before approving a claim. Claims go to MRCOOL at (270) 366-0457 or support@mrcool.com.
Documents
Manuals and documents
Specs and ratings
Check the ratings yourself: enter AHRI reference number 216032554, date 02-25-2025 and certificate number 133849934198986439 at ahridirectory.org.
FAQ
Questions people ask
Still have a question? A licensed HVAC pro answers texts Monday to Friday, 8 AM to 5 PM Central.
Text a pro: (479) 488-3576What does it pair with?
MRCOOL's AHRI certificate 216032554 rates this indoor unit with the EZPRO-12-HP-C-11516D-O outdoor unit. That outdoor unit is available on its own, or get both together in the complete 12K system.
What comes with it?
The indoor unit, the DIYPRO cable, the remote, the Smart Controller Kit and the mounting and drain parts. The 16 ft pre-charged line set comes with the outdoor unit.
How loud is it?
MRCOOL lists 44.5 / 40 / 35 / 25.5 / 17.5 dB(A) from turbo down to silent mode.
Can I control it from my phone?
Yes. A Smart Controller Kit comes with the indoor unit for control from a smartphone app, and the remote is included too.
What's the warranty?
MRCOOL covers parts for 1 year and the compressor for 2 years from your proof-of-purchase date, with no registration needed. See the warranty section above for details.
Pictures and video
See the MRCOOL Easy Pro 5th Gen up close
The Easy Pro in 30 seconds
A short video from MRCOOL. The Easy Pro is its lowest-cost mini split that you can put in yourself.
8 things to know








This is the indoor unit by itself. It pairs with the 12,000 BTU outdoor unit. Want both in one order? See the complete 12,000 BTU system.
Pictures and video are from MRCOOL. They show the complete system.
Watch MRCOOL's Easy Pro install guide (6 minutes)
MRCOOL's own install video for the Easy Pro. It goes from the wall plate to the first start. MRCOOL notes that some of the video shows another DIY model, so follow the manual for the details.
Can you put it in yourself? Yes. MRCOOL made the Easy Pro for do-it-yourself install. The line set comes filled with refrigerant and screws on with two wrenches. You do not need a vacuum pump, gauges or a refrigerant license.
The whole 12,000 BTU Easy Pro 5th Gen install, step by step
- Put up the wall plate. Use the paper template to mark the screw holes. Make the plate level and screw it on. Keep the indoor unit at least 6 ft above the floor. The ceiling must be at least 7.3 ft high.
- Drill the wall hole. Drill one 2.5 inch hole through the wall. Tilt it down a little toward the outside so water runs out. Slide in the plastic wall sleeve.
- Get the lines ready. Gently bend the copper lines on the indoor unit so they point out the back. Bundle them with the drain hose and the cable.
- Hang the indoor unit. Push the bundle through the hole. Hook the unit on the top of the plate and press the bottom in. Get a helper for the lift.
- Plug in the Wi-Fi kit. Plug the Smart Controller Kit into the indoor unit the way its sheet shows.
- Set the outdoor unit. Fit the drain joint. Put the unit on a level pad or a wall bracket and bolt it down with M10 bolts. Leave room for air around it.
- Run the line set. Unroll it gently between the two units. Do not cut it. It is filled with refrigerant.
- Hook up the Quick Connect lines. Start each fitting by hand so it goes on straight. Hold the nut marked 1 still and turn the nut marked 2 until it is snug. Do not use a socket wrench.
- Open the two valves. Take off each valve cap with a 19 mm wrench. Turn each valve to the left with the 5 mm Allen key until it stops. Do not force it. Put the caps back on tight.
- Check for leaks. Brush or spray soapy water on every fitting. Bubbles mean a leak.
- Do the wiring. Turn the breaker off first. The cable from the indoor unit and the power from your home both connect at the outdoor unit. Match each wire to the diagram.
- Turn it on and test it. Run Cool, then Heat. MRCOOL says to test it for at least 30 minutes and to check the fittings for leaks again while it runs.
Tools you need
- Drill and a 2.5 inch core drill or hole saw
- Open-end wrenches: 19 mm, 22 or 24 mm, and 24 or 27 mm. Or two adjustable wrenches
- 5 mm Allen key (one comes in the box)
- Phillips screwdriver
- Level, tape measure and stud finder
- Leak spray or soapy water
- Gloves and eye protection
Before you start
- Power: the outdoor unit is wired to its own 115V circuit. The biggest breaker it can use is 20 amps. If your home does not have that circuit yet, have an electrician add it.
- Line set: it is 16 ft long. Do not cut it. Need more length? Longer Quick Connect line sets are sold on their own.
- The fittings seal one time. Pick both spots before you hook them up.
- Room: the room must be at least 12 sq ft, with a ceiling at least 7.3 ft high.
- Weight: the indoor unit weighs about 25 lb and the outdoor unit about 55 lb. Get a helper.
These steps follow MRCOOL's Easy Pro 5th Gen installation manual. Read the full manual (PDF) before you start.
Day to day
Using the Easy Pro
Controls
- Five modes: Auto, Cool, Heat, Dry and Fan.
- Follow Me: the remote reads the temperature where you are and tells the unit.
- Turbo: the strongest fan, to heat or cool the room fast.
- Silence and Sleep: run quieter and use less power at night.
- Timer: turn on or off in up to 24 hours.
Set up the phone app
- A Smart Controller Kit comes in the box.
- Plug it into the indoor unit (step 5 above).
- Get MRCOOL's app on your iPhone or Android phone. The sheet in the box names the app.
- Follow the sheet to add your unit to your Wi-Fi.
Care
- Clean the filter every two weeks. Lift the front panel, pull the filter out, wash it in warm water with mild soap and let it air dry out of the sun.
- Active Clean: press Clean on the remote. The unit cleans itself and shuts off in 20 to 45 minutes.
- Auto restart: after a power outage it comes back on by itself.
What size hole do I drill?
One hole, 2.5 inches wide. Tilt it down a little toward the outside so water drains out. The plastic wall sleeve comes in the box.
Can I cut the line set if it is too long?
No. It is filled with refrigerant.
Can I take the fittings apart and use them again?
MRCOOL says the fittings are made to go on one time. They may leak if you take them apart and hook them up again. Pick both spots before you hook them up.
Can I plug it into a wall outlet?
No. The outdoor unit is wired to its own 115V circuit with a breaker up to 20 amps. If your home does not have that circuit yet, have an electrician add it.
How high does the indoor unit go?
At least 6 ft above the floor, in a room with a ceiling at least 7.3 ft high.
What tools do I need?
A drill with a 2.5 inch hole saw, open-end or adjustable wrenches, a 5 mm Allen key, a Phillips screwdriver, a level, a tape measure, and leak spray or soapy water.
Does it need a drain?
Yes. Water from the indoor unit runs out through a drain hose. The hose goes through the same wall hole as the lines and has to run downhill.
How often do I clean the filter?
Every two weeks. Lift the front panel, pull the filter out, wash it in warm water with mild soap and let it air dry out of the sun.
How heavy are the two units?
The indoor unit weighs about 25 lb and the outdoor unit about 55 lb. Get a helper for the lifts.
Does it come back on after the power goes out?
Yes. It has auto restart, so it turns back on by itself when the power returns.
What refrigerant does it use?
R-454B. The outdoor unit and the line set come filled at the factory. You do not add any.






