Not what you were looking for? Find your system:





MRCOOL DIY Select
MRCOOL DIY Select 24,000 BTU Outdoor Unit Only, 230V (Indoor Unit Sold Separately) (DIYS-24-HP-C-230A11-O)
Model DIYS-24-HP-C-230A11-O
Outdoor unit only. It needs the matching indoor unit to heat and cool. Most people get both together.
Get the complete system: indoor + outdoor$1,899Already have the indoor unit? Add this one to your cart below.
- Capacity24,000 BTU
- Power208-240V
- Max breaker20 A
- Sound61 dB(A)
- Weight95.90 lb
- Install it yourself: the 11.5 ft line set comes pre-charged, so no vacuum pump or gauges
- 24,000 BTU heat pump for heating and cooling
- Control it with the remote, your phone, Alexa or Google Assistant
- Pairs with the matching indoor unit, or get both as a complete system
- Gold Fin coating protects the outdoor coil from corrosion
In stock
Free shipping · Ships in 1–2 business days
Secure checkout through Shopify
- Authorized MRCOOL dealer
- Licensed HVAC contractor
- Free shipping
- 30-day returns
- Free cancellation before it ships
Authorized MRCOOL dealer. You get new, genuine MRCOOL equipment with the full MRCOOL warranty. A licensed HVAC pro answers your texts.
About usRun by a licensed HVAC contractor. Text our team your sizing or install questions, Monday to Friday, 8 AM to 5 PM Central.
About usThis ships free. Orders under $300 ship for $19.95. You get tracking by email when it ships.
Shipping details30-day returns. Ask within 30 days of delivery. Returns ship back by carrier from your home. Send it back unopened for a refund, minus a 15% restocking fee. If it arrives damaged, broken or wrong, there is no fee and we pay the return shipping.
Return policyFree cancellation. Cancel before your order ships and you pay nothing.
Return policyAdd to your orderChecked to fit this unit
-
MRCOOL Condenser Wall Bracket for 24K and 36K Systems (MB440A) MRCOOL makes this bracket for its 24K and 36K outdoor units. This outdoor unit weighs 95.9 lb.$121.00
-
MRCOOL Condenser Riser, 6 in Rubber, Set of Two (H600-B) Lifts the outdoor unit 6 in off the ground. The unit's feet are 26.1 in apart.$59.00
-
MRCOOL DIY 5th Gen 25 ft Line Set 3/8 x 5/8 in with DIY Pro Cable, R-454B (for 24K and 36K Indoor Units) (DIY25-3858C-O) 25 ft, replaces the 11.5 ft set. Same R-454B refrigerant and 3/8 x 5/8 in line size as this unit. Cable included.$613.00
-
MRCOOL DIY 5th Gen 35 ft Line Set 3/8 x 5/8 in with DIY Pro Cable, R-454B (for 24K and 36K Indoor Units) (DIY35-3858C-O) 35 ft, replaces the 11.5 ft set. Same R-454B refrigerant and 3/8 x 5/8 in line size as this unit. Cable included.$565.00
-
MRCOOL DIY 5th Gen 50 ft Line Set 3/8 x 5/8 in with DIY Pro Cable, R-454B (for 24K and 36K Indoor Units) (DIY50-3858C-O) 50 ft, replaces the 11.5 ft set. Same R-454B refrigerant and 3/8 x 5/8 in line size as this unit. Cable included.$662.00
-
MRCOOL DIY Line Set Coupler Kit with 75 ft DIY Pro Cable for 24k and 36k Units (DIYCOUPLER-3858K75C) Joins two 3/8 x 5/8 in line sets for a longer run. Comes with 75 ft of DIY Pro Cable. Keep the total line at 75 ft or less.$451.00
-
MRCOOL LineGuard 4.5 in Line Set Cover Kit, 12 ft, White (MLG450) 12 ft cover that hides the line set, cable and drain on the outside wall. White.$132.00
-
MRCOOL LineGuard 4.5 in Line Set Cover Kit, 12 ft, Gray (MLG450-G-01) 12 ft cover that hides the line set, cable and drain on the outside wall. Gray.$133.00
-
MRCOOL LineGuard 4.5 in Line Set Cover Kit, 12 ft, Tan (MLG450-T-01) 12 ft cover that hides the line set, cable and drain on the outside wall. Tan.$133.00
This is the outdoor unit only. It pairs with the DIYS-24-HP-WMAH-230A13-O indoor unit (white) or the DIYS-24-HP-B-WMAH-230A13-O (black). Want both? Get the complete 24K system.
Questions? Text a licensed HVAC pro. (479) 488-3576 · Mon to Fri, 8 AM to 5 PM CentralProduct overview
About this unit
The MRCOOL DIY Select 24,000 BTU outdoor unit (model DIYS-24-HP-C-230A11-O) is the heat pump condenser for a single-zone ductless system. It runs on 208/230V power and is sold without an indoor unit. Paired with the matching indoor unit, the system is rated 16.5 SEER2 and 8.3 HSPF2 and covers up to 1,050 sq ft.
What you need to complete the system
Add the matching indoor unit: DIYS-24-HP-WMAH-230A13-O (white) or DIYS-24-HP-B-WMAH-230A13-O (black). It ships with an 11.5 ft line set (3/8 x 5/8 in) that is pre-charged with refrigerant and fitted with Quick Connect couplings.
Electrical and sound
The outdoor unit needs its own dedicated circuit with a 20 A maximum breaker. It runs at 61 dB(A). A Gold Fin coating helps protect the coil from corrosion.
Buying from Cool Air Depot
- Authorized MRCOOL dealerNew equipment with the full MRCOOL factory warranty.
- Free shippingThis item ships free.
- 30-day returnsRequest a return within 30 days of delivery, or cancel free before your order ships. Return policy
- Licensed HVAC supportText a pro at (479) 488-3576, Monday to Friday, 8 AM to 5 PM Central.
What's included
What's in the box
In the box
- Outdoor unitDIYS-24-HP-C-230A11-O
- 11.5 ft install kitPre-charged Quick Connect line set, 3/8 x 5/8 in. The communication cable comes with the indoor unit.
Not included: the indoor unit.
Specifications
Specs for this outdoor unit
- SystemDIYS-24-HP-230A11-O
- Indoor unitDIYS-24-HP-WMAH-230A13-O
- Outdoor unitDIYS-24-HP-C-230A11-O
Outdoor unit
| Model | DIYS-24-HP-C-230A11-O |
|---|---|
| Size (W x D x H) | 35.04 x 13.46 x 26.50 in |
| Weight (unit / boxed) | 95.90 / 117.73 lb |
| Box size (W x D x H) | 42.91 x 19.88 x 35.03 in |
| Mounting foot spacing | 26.1 x 13.9 in, M10 bolts |
| Sound | 61 dB(A) |
Electrical
| Power supply | 208-230V, 1-phase, 60 Hz |
|---|---|
| Minimum circuit ampacity | 19 A |
| Maximum breaker or fuse | 20 A |
| Minimum wire size (manual's chart) | 12 AWG |
Refrigerant and line set
| Refrigerant | R-454B |
|---|---|
| Factory charge | 50.44 oz |
| Pipe sizes (liquid / gas) | 3/8 in / 5/8 in |
| Line set included | 11.5 ft, pre-charged Quick Connect |
| Maximum line length | 75 ft |
| Maximum height difference between units | 75 ft |
Paired with DIYS-24-HP-WMAH-230A13-O
| Cooling capacity (at 95°F) | 23,000 BTU/h |
|---|---|
| Heating capacity (at 47°F) | 23,000 BTU/h |
| SEER2 | 16.5 |
| EER2 | 8.6 |
| HSPF2 (Region IV) | 8.3 |
| HSPF2 (Region V) | 6.3 |
Paired ratings are from AHRI certificate 218004487 for this outdoor unit with the DIYS-24-HP-WMAH-230A13-O indoor unit. Other figures come from MRCOOL's DIY Select spec sheet and installation manual. MRCOOL notes that spec sheet figures may change during production.
Installation
How a DIY install works
- 1Pick the spot
A level pad on the ground or a wall bracket, with the clearances the manual shows around the unit.
- 2Fit the drain joint and mount it
Fit the drain joint to the bottom of the unit, then bolt it down with M10 bolts. The mounting feet are 26.1 x 13.9 in apart.
- 3Connect the line set
Thread each Quick Connect fitting by hand, then tighten it with two wrenches. There's no vacuuming and no refrigerant to add. Check every joint with leak-detection spray or soapy water.
- 4Open the valves
Remove each valve cover with a 19 mm wrench, open the valve counterclockwise with a 5 mm Allen key until it stops, then put the cover back on tight.
- 5Power
The outdoor unit needs its own 208-230V circuit with a breaker up to 20 A.
Power and tools
Electrical
- Power supply
- 208-230V, 1-phase, 60 Hz
- Outdoor unit, minimum circuit ampacity
- 19 A
- Outdoor unit, maximum breaker or fuse
- 20 A
- Minimum wire size (manual's chart)
- 12 AWG.
- Connection
- Hardwired to its own circuit
Tools you'll need
- Open-end wrenches: 19 mm, 22/24 mm and 24/27 mm (an HVAC torque wrench is best if you have one)
- 5 mm Allen key for the valves
- Drill and masonry bit for the M10 anchor bolts
- Leak-detection spray or soapy water
- Gloves and eye protection
Warranty
MRCOOL's factory warranty
Covered
- Starts on your proof-of-purchase date. No registration is needed.
- Parts include the remote, the Wi-Fi module, the pre-charged line set and the parts inside the indoor and outdoor units (the compressor has its own 2-year term).
- Repaired or replaced parts are covered for the rest of the original term, or 30 days, whichever is longer.
Warranty exclusions
- Labor, shipping and refrigerant costs
- Damage from an install that doesn't follow the manual, local codes or permits
- A unit moved from its first install address. The warranty doesn't transfer to a new owner.
Summary of MRCOOL's limited warranty for the DIY Select series (rev. 03.31.26). The PDF below is the full terms. MRCOOL may ask for a licensed HVAC technician to diagnose a problem before approving a claim. Claims go to MRCOOL at (270) 366-0457 or support@mrcool.com.
Documents
Manuals and documents
Specs and ratings
Check the ratings yourself: enter AHRI reference number 218004487, date 03-17-2026 and certificate number 134182452329945981 at ahridirectory.org.
FAQ
Questions people ask
Still have a question? A licensed HVAC pro answers texts Monday to Friday, 8 AM to 5 PM Central.
Text a pro: (479) 488-3576What does it pair with?
MRCOOL's AHRI certificate 218004487 rates this outdoor unit with the DIYS-24-HP-WMAH-230A13-O indoor unit. The black DIYS-24-HP-B-WMAH-230A13-O is the same indoor unit in a different color. The indoor unit is available on its own, or get both together in the complete 24K system.
Does it come with a line set?
Yes. MRCOOL lists this outdoor unit with the 11.5 ft install kit, a pre-charged Quick Connect line set. The communication cable comes with the indoor unit. Longer line sets are available.
How long can the line run be?
MRCOOL's installation manual allows up to 75 ft of line and up to 75 ft of height difference for this size.
How is it powered?
It's hardwired to its own 208-230V circuit with a breaker up to 20 A.
Where does the outdoor unit go?
On a level pad on the ground or on a wall bracket, bolted down with M10 bolts. The outdoor unit weighs about 96 lb.
Do I need a vacuum pump or gauges?
No. The line set comes charged with refrigerant and connects with wrenches. You open the unit's valves with a 5 mm Allen key once the line set is connected.
What's the warranty?
MRCOOL covers parts, including the pre-charged line set, for 1 year and the compressor for 2 years from your proof-of-purchase date, with no registration needed. See the warranty section above for details.
Pictures and video
See the MRCOOL DIY Select up close
The DIY Select in 28 seconds
A short video from MRCOOL. The DIY Select is made so any homeowner can put it in. No contractor and no special tools.
8 things to know








This is the outdoor unit by itself. It pairs with the 24,000 BTU indoor unit in white or black. Want both in one order? See the complete 24,000 BTU system.
Pictures and video are from MRCOOL. They show the complete system.
Watch MRCOOL's DIY Select install guide (6 minutes)
MRCOOL's own install video for the DIY Select. It goes from the wall plate to the first start. MRCOOL notes that some of the video shows another DIY model, so follow the manual for the details.
Can you put it in yourself? Yes. MRCOOL made the DIY Select for do-it-yourself install. The line set comes filled with refrigerant and screws on with two wrenches. You do not need a vacuum pump, gauges or a refrigerant license.
The whole 24,000 BTU DIY Select install, step by step
- Put up the wall plate. Use the paper template to mark the screw holes. Make the plate level and screw it on. Keep the indoor unit at least 6 ft above the floor. The ceiling must be at least 7.3 ft high.
- Drill the wall hole. Drill one 3.54 inch hole through the wall. Tilt it down a little toward the outside so water runs out. Slide in the plastic wall sleeve.
- Get the lines ready. Gently bend the copper lines on the indoor unit so they point out the back. Bundle them with the drain hose and the cable.
- Hang the indoor unit. Push the bundle through the hole. Hook the unit on the top of the plate and press the bottom in. Get a helper for the lift.
- Plug in the Wi-Fi module. Plug the MRCOOL Comfort Wi-Fi module into the indoor unit the way its sheet shows.
- Set the outdoor unit. Fit the drain joint. Put the unit on a level pad or a wall bracket and bolt it down with M10 bolts. Leave room for air around it.
- Run the line set. Unroll it gently between the two units. Do not cut it. It is filled with refrigerant.
- Hook up the Quick Connect lines. Start each fitting by hand so it goes on straight. Hold the nut marked 1 still and turn the nut marked 2 until it is snug. Do not use a socket wrench.
- Open the two valves. Take off each valve cap with a 19 mm wrench. Turn each valve to the left with the 5 mm Allen key until it stops. Do not force it. Put the caps back on tight.
- Check for leaks. Brush or spray soapy water on every fitting. Bubbles mean a leak.
- Do the wiring. Turn the breaker off first. The DIYPRO cable from the indoor unit and the power from your home both connect at the outdoor unit. Match each wire to the diagram.
- Turn it on and test it. Run Cool, then Heat. MRCOOL says to test it for at least 30 minutes and to check the fittings for leaks again while it runs.
Tools you need
- Drill and a 3.54 inch core drill or hole saw
- Open-end wrenches: 19 mm, 22 or 24 mm, and 24 or 27 mm. Or two adjustable wrenches
- 5 mm Allen key (one comes in the box)
- Phillips screwdriver
- Level, tape measure and stud finder
- Leak spray or soapy water
- Gloves and eye protection
Before you start
- Power: the outdoor unit is wired to its own 208-230V circuit. The biggest breaker it can use is 20 amps. If your home does not have that circuit yet, have an electrician add it.
- Line set: it is 11.5 ft long. Do not cut it. Need more length? Longer Quick Connect line sets are sold on their own.
- The fittings seal one time. Pick both spots before you hook them up.
- Room: the room must be at least 12 sq ft, with a ceiling at least 7.3 ft high.
- Weight: the indoor unit weighs about 35 lb and the outdoor unit about 96 lb. Get a helper.
These steps follow MRCOOL's DIY Select installation manual (version date August 5, 2026). Read the full manual (PDF) before you start.
Day to day
Using the DIY Select
Controls
- Five modes: Auto, Cool, Heat, Dry and Fan.
- Follow Me: the remote reads the temperature where you are and tells the unit.
- Turbo: the strongest fan, to heat or cool the room fast.
- Silence and Sleep: run quieter and use less power at night.
- Timer: turn on or off in up to 24 hours.
Set up the phone app
- A MRCOOL Comfort Wi-Fi module comes in the box with the indoor unit.
- Plug it into the indoor unit (step 5 above).
- Get the MRCOOL Comfort app on your iPhone or Android phone.
- Follow the sheet in the box to add your unit to your Wi-Fi.
- MRCOOL has a 3 minute video that walks through the app.
Care
- Clean the filter every two weeks. Lift the front panel, pull the filter out, wash it in warm water with mild soap and let it air dry out of the sun.
- Active Clean: press Clean on the remote. The unit cleans itself and shuts off in 20 to 45 minutes.
- Auto restart: after a power outage it comes back on by itself.
What size hole do I drill?
One hole, 3.54 inches wide. Tilt it down a little toward the outside so water drains out. The plastic wall sleeve comes in the box with the indoor unit.
Does it come in black?
Yes. The DIY Select comes with a white or a black indoor unit. The outdoor unit is the same for both.
Can I cut the line set if it is too long?
No. It is filled with refrigerant.
Can I take the fittings apart and use them again?
MRCOOL says the fittings are made to go on one time. They may leak if you take them apart and hook them up again, and that can void the warranty. Pick both spots before you hook them up.
Can I plug it into a wall outlet?
No. The outdoor unit is wired to its own 208-230V circuit with a breaker up to 20 amps. If your home does not have that circuit yet, have an electrician add it.
How high does the indoor unit go?
At least 6 ft above the floor, in a room with a ceiling at least 7.3 ft high.
What tools do I need?
A drill with a 3.54 inch hole saw, open-end or adjustable wrenches, a 5 mm Allen key, a Phillips screwdriver, a level, a tape measure, and leak spray or soapy water.
Does it need a drain?
Yes. Water from the indoor unit runs out through a drain hose. The hose goes through the same wall hole as the lines and has to run downhill.
How often do I clean the filter?
Every two weeks. Lift the front panel, pull the filter out, wash it in warm water with mild soap and let it air dry out of the sun.
How heavy are the two units?
The indoor unit weighs about 35 lb and the outdoor unit about 96 lb. Get a helper for the lifts.
Does it come back on after the power goes out?
Yes. It has auto restart, so it turns back on by itself when the power returns.
What refrigerant does it use?
R-454B. The outdoor unit and the line set come filled at the factory. You do not add any.