Not what you were looking for? Find your system:
MRCOOL DIY 5th Gen OuttaSight
MRCOOL DIY OuttaSight 6,000 BTU One-Way Ceiling Cassette, Indoor Unit Only, 230V (Outdoor Unit Sold Separately) (DIYCASSETTE06HP-230D25-O)
Model DIYCASSETTE06HP-230D25-O
Indoor unit only. It hooks up to a MRCOOL DIY multi-zone outdoor unit. Each room gets its own indoor unit.
Build my multi-room systemAlready have the outdoor unit? Add this one to your cart below.
- Power208-240V
- RefrigerantR-454B
- Made for do-it-yourself installation with MRCOOL's pre-charged Quick Connect line sets
- 6,000 BTU heating and cooling for up to 200 sq ft
- Ductless: heats and cools one room with no ductwork to install
- Control it with the remote, your phone, Alexa or Google Assistant
- Pairs with the matching outdoor unit, or get both as a complete system
In stock
Free shipping · Ships in 1–2 business days
Secure checkout through Shopify
- Authorized MRCOOL dealer
- Licensed HVAC contractor
- Free shipping
- 30-day returns
- Free cancellation before it ships
Authorized MRCOOL dealer. You get new, genuine MRCOOL equipment with the full MRCOOL warranty. A licensed HVAC pro answers your texts.
About usRun by a licensed HVAC contractor. Text our team your sizing or install questions, Monday to Friday, 8 AM to 5 PM Central.
About usThis ships free. Orders under $300 ship for $19.95. You get tracking by email when it ships.
Shipping details30-day returns. Ask within 30 days of delivery. Returns ship back by carrier from your home. Send it back unopened for a refund, minus a 15% restocking fee. If it arrives damaged, broken or wrong, there is no fee and we pay the return shipping.
Return policyFree cancellation. Cancel before your order ships and you pay nothing.
Return policyAdd to your orderChecked to fit this unit
-
MRCOOL DIY 5th Gen 16 ft Line Set 1/4 x 3/8 in, R-454B (for 6K, 9K and 12K Indoor Units) (DIY16-1438-O) DIY 5th Gen copper line set for R-454B, 1/4 x 3/8 in, the pipe size this unit uses. Not included with this unit.$227.00
-
MRCOOL DIY 5th Gen 25 ft Line Set 1/4 x 3/8 in, R-454B (for 6K, 9K and 12K Indoor Units) (DIY25-1438-O) DIY 5th Gen copper line set for R-454B, 1/4 x 3/8 in, the pipe size this unit uses$264.00
-
MRCOOL DIY 5th Gen 35 ft Line Set 1/4 x 3/8 in with DIY Pro Cable, R-454B (for 6K, 9K and 12K Indoor Units) (DIY35-1438C-O) DIY 5th Gen copper line set for R-454B, 1/4 x 3/8 in, with DIY Pro cable, the pipe size this unit uses$502.00
-
MRCOOL DIY 5th Gen 50 ft Line Set 1/4 x 3/8 in with DIY Pro Cable, R-454B (for 6K, 9K and 12K Indoor Units) (DIY50-1438C-O) DIY 5th Gen copper line set for R-454B, 1/4 x 3/8 in, with DIY Pro cable, the pipe size this unit uses$587.00
Product overview
About this unit
The MRCOOL DIY OuttaSight 6,000 BTU ceiling cassette (model DIYCASSETTE06HP-230D25-O) is a one-way cassette that mounts in the ceiling instead of on the wall. It fits between ceiling joists on 16 in centers and sits nearly flush, so nothing is mounted on the wall. It runs on 208/230V power, and MRCOOL rates it for up to 250 sq ft.
What you need to complete the system
Connect it to a DIY 5th Gen multi-zone outdoor unit as one room of a system with up to six rooms. Each room needs its own line set in 1/4 x 3/8 in. Our DIY 5th Gen line sets come in 16, 25, 35 and 50 ft lengths, and the 35 and 50 ft sets include DIY Pro cable. The multi-room builder matches the outdoor unit and line sets for you.
Features
It runs as quietly as 23.5 dB(A) on its lowest fan setting. It comes with a remote control and DIYPRO cable.
Buying from Cool Air Depot
- Authorized MRCOOL dealerNew equipment with the full MRCOOL factory warranty.
- Free shippingThis item ships free.
- 30-day returnsRequest a return within 30 days of delivery, or cancel free before your order ships. Return policy
- Licensed HVAC supportText a pro at (479) 488-3576, Monday to Friday, 8 AM to 5 PM Central.
What's included
What's in the box
In the box
- Indoor unitDIYCASSETTE06HP-230D25-O, with remote control and DIYPRO cable
Not included: the outdoor unit and the line set.
Specifications
Specs
Electrical
| Power supply | 208/230V, 1Ph, 60Hz |
|---|---|
| Indoor MCA (A) | 3 |
Coverage
| Max coverage area (sq ft, ideal) | Up to 250 |
|---|
Fan motor
| Output (W) | 30 |
|---|---|
| Rated load amps (A) | 0.8 |
| Speed Hi/Mi/Lo (r/min) | 1024/944/784 |
Airflow
| Turbo/Hi/Mi/Lo/Si (CFM) | 341 / 294 / 259 / 235 / 235 |
|---|
Noise
| Turbo/Hi/Mi/Lo/Si dB(A) | 46.5 / 37.5 / 35.5 / 26 / 23.5 |
|---|
Evaporator
| Rows | 2 |
|---|---|
| Tube outer diameter (mm) | 7 |
| Tube type | Inner groove tube |
| Fin spacing (mm) | 1.3 |
| Fin type | Hydrophilic aluminum |
| Number of circuits | 3 |
Dimensions
| Net WxDxH (in) | 50.3 x 13.1 x 8.9 |
|---|---|
| Packing WxDxH (in) | 57.6 x 22.4 x 22.6 |
Weight
| Net/gross (lb) | 45 / 88 |
|---|
Piping
| Liquid / gas size (in) | 1/4 / 3/8 |
|---|
Figures come from MRCOOL's spec sheet, installation manual and AHRI certificate for this model. MRCOOL notes that spec sheet figures may change during production.
Installation
How a DIY install works
- 1Pick the spots
Follow the manual for indoor unit height, ceiling height, minimum room area and clearances around both units.
- 2Mount the units
Mount the indoor unit as the manual shows, and bolt the outdoor unit to a pad or wall bracket.
- 3Connect the Quick Connect line set
Thread each fitting by hand and tighten it with two wrenches. There's no vacuuming and no refrigerant to add. Check every joint with leak-detection spray.
- 4Open the valves
Open the outdoor unit's valves with a 5 mm Allen key, as the manual shows.
- 5Power and first start
Connect the DIYPRO cable and wire the power circuit to local code.
Power and tools
Electrical
- Power supply
- 208/230V
Warranty
MRCOOL's factory warranty
Covered
- Starts on your proof-of-purchase date. No registration is needed.
- Parts include the remote, the Wi-Fi dongle, the pre-charged line sets and the parts inside the indoor and outdoor units (the compressor has its own 7-year term).
Warranty exclusions
- Labor, shipping and refrigerant costs
- Damage from an install that doesn't follow the manual, local codes or permits
- A unit moved from its first install address
Summary of MRCOOL's limited warranty for the 5th Gen DIY series (rev. 07.03.25). The PDF below is the full terms. MRCOOL may ask for a licensed HVAC technician to diagnose a problem before approving a claim. Claims go to MRCOOL at (270) 366-0457 or support@mrcool.com.
Documents
Manuals and documents
Install and use
Specs and ratings
Warranty
For your installer
FAQ
Questions people ask
Still have a question? A licensed HVAC pro answers texts Monday to Friday, 8 AM to 5 PM Central.
Text a pro: (479) 488-3576Which line set does it use?
It uses a DIY 5th Gen Quick Connect line set, sold separately so you can pick your length.
How big a space will it handle?
MRCOOL rates it for up to 250 sq ft.
What's the warranty?
MRCOOL covers parts, including the pre-charged line set, for 5 years and the compressor for 7 years from your proof-of-purchase date, with no registration needed. See the warranty section above for details.
Pictures
See the MRCOOL OuttaSight ceiling cassette up close
6 things to know






This is the ceiling cassette by itself. It is made for multi-zone systems and pairs with a DIY 5th Gen multi-zone outdoor unit. The Multi Room Builder helps you pick the parts.
Pictures are from MRCOOL.
Watch MRCOOL's OuttaSight install guide (6 minutes)
MRCOOL's own install video for the OuttaSight ceiling cassette. It goes from opening the box to turning it on.
Can you put it in yourself? Yes. MRCOOL made the OuttaSight for do-it-yourself install. The line set comes filled with refrigerant and screws on with two wrenches. You do not need a vacuum pump, gauges or a refrigerant license.
The OuttaSight install, step by step
- Get the cassette ready. Open the box. Take the knock-out off the control box so the power wire can come in.
- Find the spot in the ceiling. The cassette sits between two joists that are 16 inches apart. Use the cardboard template to mark it.
- Cut the opening. Cut the ceiling 16.93 inches by 51.18 inches.
- Lift the cassette into place. Lift it by its four hanger brackets and screw it to the joists. It weighs 45 lb. Get a helper.
- Connect the DIYPRO cable. Plug the cable into the cassette. The other end goes to the outdoor unit.
- Hook up the drain. Fit the drain pipe adapter. Run 3/4 inch PVC pipe that slopes down. If the pipe has to go up first, it can rise no more than 20.8 inches.
- Connect the line set at the cassette. Start each Quick Connect fitting by hand so it goes on straight. Then snug it with two wrenches.
- Run everything outside. The line set, the drain line and the cable go out through a hole in the outside wall. Tilt the hole down toward the outside.
- Set the outdoor unit. Put it on a level pad or a wall bracket and bolt it down. Leave room for air around it.
- Connect the lines at the outdoor unit. Unroll the line set gently. Do not cut it. Snug each fitting with two wrenches.
- Open the valves and check for leaks. Take off the valve caps. Turn each valve to the left with the 5 mm Allen key until it stops. Then brush soapy water on every fitting. Bubbles mean a leak.
- Wrap the fittings. Put on the sound pads and the insulation sleeves. Fit the water tray under the fittings at the cassette.
- Run the power. Turn the breaker off first. Match each wire to the wiring diagram.
- Put on the panel and turn it on. Clip the panel on and plug in its wire. Plug in the Smart Controller. Turn the breaker on and run Cool, then Heat.
Tools you need
- Drywall saw, drill and stud finder
- Open-end wrenches: 22, 24 and 26 mm. Or two adjustable wrenches
- 10 mm and 19 mm wrenches for the valve caps
- 5 mm Allen key and a Phillips screwdriver
- 3/4 inch PVC pipe and fittings for the drain
- Core drill or hole saw for the hole in the outside wall
- Level and tape measure
- Leak spray or soapy water
- Ladder, gloves and eye protection
Before you start
- Ceiling: you need joists that are 16 inches apart. The cassette is 50.3 inches long, 13.1 inches wide and 8.9 inches tall, so it needs that much room above the ceiling.
- Power: it runs on 208/230V. The outdoor unit you pair it with sets the breaker size. If your home does not have that circuit yet, have an electrician add it.
- Line set: it is sold on its own, so you pick the length you need. Do not cut it. See line sets and couplers.
- The fittings seal one time. Pick both spots before you hook them up.
- Drain: plan where the water will go before you cut the ceiling.
These steps follow MRCOOL's DIY OuttaSight installation manual (version date December 2, 2025). Read the full manual before you start. It is under Manuals on this page.
Day to day
Using the OuttaSight
Controls
- Five modes: Auto, Cool, Heat, Dry and Fan.
- Follow Me: the remote reads the temperature where you are and tells the unit.
- Breeze Away: points the air away from you.
- Turbo: the strongest fan, to heat or cool the room fast.
- Silence and Sleep: run quieter and use less power at night.
- Timer: turn on or off in up to 24 hours.
Set up the phone app
- A Smart Controller Kit comes in the box.
- Plug it in when you put the panel on (the last step above).
- Get the MRCOOL SmartHVAC app on your iPhone or Android phone.
- Follow the sheet in the kit to add your unit to your Wi-Fi.
Care
- The filter comes down to you. Hold Mode and the down arrow on the remote for 3 seconds. Then press the down arrow. The grille lowers as much as 4.9 ft.
- Clean the filter every two weeks. Wash it in warm water with mild soap and let it air dry out of the sun. Press the up arrow to raise the grille.
- Active Clean: the unit cleans itself and shuts off in 20 to 45 minutes.
How far apart do the joists need to be?
16 inches apart, measured center to center. The opening you cut in the ceiling is 16.93 inches by 51.18 inches.
How much room does it need above the ceiling?
The cassette is 8.9 inches tall, 50.3 inches long and 13.1 inches wide. It sits up in the joist space.
How do I get to the filter?
Hold Mode and the down arrow on the remote for 3 seconds, then press the down arrow. The grille lowers as much as 4.9 ft so you can take the filter out. Clean it every two weeks.
Which outdoor units does it work with?
The DIY 5th Gen multi-zone outdoor units. One outdoor unit runs two to six indoor units.
Does it need a drain?
Yes. Water runs out through 3/4 inch PVC pipe that slopes down. If the pipe has to go up first, it can rise no more than 20.8 inches.
Can I cut the line set if it is too long?
No. It is filled with refrigerant. Coil the extra length and keep every bend wider than 4 inches.
Can I plug it into a wall outlet?
No. It runs on 208/230V through the outdoor unit's circuit. If your home does not have that circuit yet, have an electrician add it.
What tools do I need?
A drywall saw, a drill, a stud finder, open-end or adjustable wrenches, a 5 mm Allen key, a Phillips screwdriver, 3/4 inch PVC pipe for the drain, a hole saw for the outside wall, a level, a tape measure, and leak spray or soapy water.
How heavy is the cassette?
45 lb. Get a helper for the lift.
How loud is it?
MRCOOL lists the cassette at 23.5 dB(A) on its quietest setting.
Can I run it from my phone?
Yes. A Smart Controller Kit comes in the box. Once it is on your Wi-Fi, you can use the MRCOOL SmartHVAC app. The remote works too.
What refrigerant does it use?
R-454B. The outdoor unit and the line set come filled at the factory. You do not add any.
Comes with a 25 ft DIYPRO cable. It links this inside unit to the outside unit and carries its power, so you do not need to buy one. For a longer run, the 35 ft and 50 ft line sets come with a longer cable.