Not what you were looking for? Find your system:
MRCOOL Advantage 5th gen
MRCOOL Advantage 5th Gen 36,000 BTU Indoor Unit Only, 230V (Outdoor Unit Sold Separately) (A-36-HP-WMAH-230D-O)
Model A-36-HP-WMAH-230D-O
Indoor unit only. It needs the matching outdoor unit to heat and cool. The complete system costs $1 less than buying both units one at a time.
Get the complete system: indoor + outdoor$2,302Already have the outdoor unit? Add this one to your cart below.
- Cooling36,000 BTU
- Efficiency18.0 SEER2
- Heating8.5 HSPF2
- Power208-240V
- RefrigerantR-454B
- 36,000 BTU heating and cooling
- Ductless: heats and cools one room with no ductwork to install
- Control it with the remote, your phone, Alexa or Google Assistant
- Pairs with the matching outdoor unit, or get both as a complete system
In stock
Free shipping · Ships in 1–2 business days
Secure checkout through Shopify
- Authorized MRCOOL dealer
- Licensed HVAC contractor
- Free shipping
- 30-day returns
- Free cancellation before it ships
Authorized MRCOOL dealer. You get new, genuine MRCOOL equipment with the full MRCOOL warranty. A licensed HVAC pro answers your texts.
About usRun by a licensed HVAC contractor. Text our team your sizing or install questions, Monday to Friday, 8 AM to 5 PM Central.
About usThis ships free. Orders under $300 ship for $19.95. You get tracking by email when it ships.
Shipping details30-day returns. Ask within 30 days of delivery. Returns ship back by carrier from your home. Send it back unopened for a refund, minus a 15% restocking fee. If it arrives damaged, broken or wrong, there is no fee and we pay the return shipping.
Return policyFree cancellation. Cancel before your order ships and you pay nothing.
Return policy Questions? Text a licensed HVAC pro. (479) 488-3576 · Mon to Fri, 8 AM to 5 PM CentralProduct overview
About this unit
The MRCOOL Advantage 5th Gen 36,000 BTU indoor unit (model A-36-HP-WMAH-230D-O) is a wall-mounted air handler for one room or open area of up to 1,550 sq ft. It runs on 208/230V power and is sold without an outdoor unit. Paired with the matching Advantage 5th Gen 36,000 BTU outdoor unit (model A-36-HP-C-230D-O), the system is rated 18 SEER2 and 8.5 HSPF2.
What you need to complete the system
Add the matching outdoor unit, model A-36-HP-C-230D-O. It ships with a 16 ft install kit for connecting the indoor and outdoor units.
Features
It comes with a mounting plate, template, remote control and holder, plus a smart controller kit for the MRCOOL app.
Buying from Cool Air Depot
- Authorized MRCOOL dealerNew equipment with the full MRCOOL factory warranty.
- Free shippingThis item ships free.
- 30-day returnsRequest a return within 30 days of delivery, or cancel free before your order ships. Return policy
- Licensed HVAC supportText a pro at (479) 488-3576, Monday to Friday, 8 AM to 5 PM Central.
What's included
What's in the box
In the box
- Wall-mounted indoor unitA-36-HP-WMAH-230D-O, with mounting plate, template, remote control and holder
- Smart controller kitFor control from the MRCOOL app
Not included: the outdoor unit (A-36-HP-C-230D-O). The outdoor unit ships with the 16 ft install kit.
Specifications
Specs
Capacity and performance
| Cooling capacity, brochure matched pair | 36000 Btu/h |
|---|---|
| Heating capacity, brochure matched pair | 36000 Btu/h |
| SEER2 | 18.0 |
| EER2 | 9.0 |
| HSPF2-4 | 8.5 |
| HSPF2-5 | 6.8 |
| Max coverage area, ideal conditions | Up to 1550 sq ft |
| Outdoor noise, Hi | 60.5 dB(A) |
| Refrigerant | R-454B |
Electrical
| Power supply | 208-230V, 60 Hz, 1 Ph |
|---|---|
| Indoor minimum circuit | 3.0 A |
| Outdoor minimum circuit | 33.0 A |
| Indoor maximum fuse / breaker | 15.0 A |
| Outdoor maximum fuse / breaker | 35.0 A |
Dimensions and weight
| Indoor net size, W x D x H | 49.57 x 11.10 x 14.25 in |
|---|---|
| Outdoor net size, W x D x H | 37.24 x 16.14 x 31.89 in |
| Indoor packing size, W x D x H | 52.76 x 17.72 x 15.16 in |
| Outdoor packing size, W x D x H | 42.91 x 19.68 x 34.84 in |
| Indoor net / gross weight | 40.34 / 54.01 lb |
| Outdoor net / gross weight | 150.35 / 160.27 lb |
Piping
| Liquid / gas pipe size | 3/8 / 5/8 in |
|---|---|
| Minimum pipe run | 9.84 ft (3 m) |
| Standard pipe length | 24.6 ft (7.5 m) |
| Maximum pipe length | 164 ft |
| Maximum elevation | 98.4 ft |
Figures come from MRCOOL's spec sheet, installation manual and AHRI certificate for this model. MRCOOL notes that spec sheet figures may change during production.
Warranty
MRCOOL's factory warranty
Covered
- Starts on your proof-of-purchase date.
- Covers the original owner. It does not transfer to a new owner.
Warranty exclusions
- Labor, shipping and refrigerant costs
- Damage from an install that doesn't follow local codes, permits and licensing
- A unit moved from its first install address
Summary of MRCOOL's limited warranty for the Advantage 5th Gen series (rev. 07.15.26). The PDF below is the full terms. MRCOOL may ask for a licensed HVAC technician to diagnose a problem before approving a claim. Claims go to MRCOOL at (270) 366-0457 or support@mrcool.com.
Documents
Manuals and documents
Install and use
Specs and ratings
Warranty
For your installer
FAQ
Questions people ask
Still have a question? A licensed HVAC pro answers texts Monday to Friday, 8 AM to 5 PM Central.
Text a pro: (479) 488-3576Who installs it?
A licensed HVAC technician. It's built for professional installation, so any local HVAC company can install it.
Which line set does it use?
The 16 ft install kit comes with the outdoor unit.
How long can the line run be?
MRCOOL's installation manual allows up to 164 ft of line and up to 98.4 ft of height difference for this size. Longer line sets are available for longer runs.
How big a space will it handle?
MRCOOL rates it for up to 1550 sq ft.
What's the warranty?
MRCOOL covers parts for 1 year and the compressor for 2 years from your proof-of-purchase date. See the warranty section above for details.
Pictures
See the MRCOOL Advantage up close
4 things to know



This is the indoor unit by itself. It pairs with the 36,000 BTU 208-230V outdoor unit. Want both in one order? See the complete 36,000 BTU system.
Pictures are from MRCOOL. They show the complete system.
Installation
How the Advantage 36,000 BTU goes in
The Advantage hooks up the classic way. The copper lines join with flare nuts. Then a vacuum pump clears the air out of the lines before the valves are opened. Here is the whole job, start to finish.
The install, step by step
- Pick the two spots. The indoor unit goes at least 6 ft above the floor, in a room with a ceiling at least 7.3 ft high. The outdoor unit needs a level spot with room for air around it.
- Put up the wall plate. Use the cardboard template to mark the holes. Make the plate level and screw it to the wall.
- Drill the wall hole. One hole, 2.5 or 3.54 inches wide. The manual shows which one your unit takes. Tilt it so the outside end sits about 1/4 inch lower and water runs out.
- Get the lines and the drain hose ready. Hook the drain hose to the indoor unit on the same side as the copper lines. Bundle the lines, the cable and the hose, with the hose on the bottom.
- Hang the indoor unit. Feed the bundle through the wall sleeve. Hook the unit on the top of the plate and press the bottom in. It weighs about 40 lb.
- Set the outdoor unit. Fit the drain joint. Bolt the unit to a level pad or a wall bracket. It weighs about 150 lb.
- Do the wiring. Turn the breaker off first. The cable from the indoor unit and the power from the home both connect at the outdoor unit. Match each wire to the diagram.
- Connect the copper lines. Cut each line to length, smooth the cut end and flare it. Start each flare nut by hand so it goes on straight. Then tighten it with a torque wrench to the number in the manual.
- Pressure test, then pull a vacuum. Test the lines with dry nitrogen. Then run a vacuum pump for at least 15 minutes, or down to 500 microns. Close it off and wait 5 minutes. The reading should hold.
- Open the valves and check for leaks. Open both valves all the way with a hex wrench. Check every joint with soapy water or a leak detector.
- Turn it on and test it. Run Cool, then Heat. MRCOOL says to test it for at least 30 minutes.
Tools the job takes
- Hammer drill and a 2.5 or 3.54 inch core drill
- Pipe cutter and reamer
- Flaring tool
- Torque wrench
- Vacuum pump
- Manifold gauge set and a micron gauge
- Hex (Allen) wrenches
- Leak detector or soapy water
- Level, tape measure and screwdrivers
Good to know first
- Power: the outdoor unit is wired to its own 208-230V circuit. Size the wire for at least 33 amps. The biggest breaker it can use is 35 amps.
- Line set: the kit has 16 ft of copper line, 3/8 and 5/8 inch. The run has to be at least 9.84 ft and can go up to 164 ft. One unit can sit up to 98.4 ft higher than the other.
- Refrigerant: the outdoor unit comes filled with R-454B for up to 25 ft of line. A longer run needs 0.32 oz more for each extra foot.
- Not in the box: the power wire from the breaker panel, and a pad or wall bracket for the outdoor unit.
These steps follow MRCOOL's Advantage installation manual (version date October 29, 2026). The full manual is under Manuals on this page. Want lines that hook up with two wrenches and no vacuum pump? See the MRCOOL DIY 5th Gen systems.
Day to day
Using the Advantage
Controls
- Five modes: Auto, Cool, Heat, Dry and Fan.
- Follow Me: the remote reads the temperature where you are and tells the unit.
- Turbo: the strongest fan, to heat or cool the room fast.
- Silence and Sleep: run quieter and use less power at night.
- Timer: turn on or off in up to 24 hours.
Set up the phone app
- A Smart Controller Kit comes in the box.
- Hook it to the indoor unit the way its sheet shows.
- Get the MRCOOL SmartHVAC app on your iPhone or Android phone.
- Follow the sheet to add your unit to your Wi-Fi.
- Then turn it on, set the temperature and set a schedule from anywhere.
Care
- Clean the filter every two weeks. Lift the front panel, pull the filter out, wash it in warm water with mild soap and let it air dry out of the sun.
- Active Clean: press Clean on the remote. The unit cleans itself and shuts off in 20 to 45 minutes.
- Keep leaves, grass and snow away from the outdoor unit so air can move through it.
How do the lines hook up?
With flare nuts. The copper ends are flared, and each nut is tightened with a torque wrench. Then a vacuum pump pulls the air out of the lines before the valves are opened.
What tools does the install take?
A hammer drill with a core drill, a pipe cutter and reamer, a flaring tool, a torque wrench, a vacuum pump, a manifold gauge set, a micron gauge, hex wrenches, and a leak detector or soapy water.
Does the outdoor unit come with refrigerant in it?
Yes. It comes filled with R-454B for up to 25 ft of line. A longer run needs 0.32 oz more for each extra foot.
What power does it need?
The outdoor unit is wired to its own 208-230V circuit. It does not plug into a wall outlet. Size the wire for at least 33 amps. The biggest breaker it can use is 35 amps.
What size hole goes through the wall?
One hole, 2.5 or 3.54 inches wide, depending on the unit. MRCOOL's manual shows which. Tilt it down toward the outside so water drains out.
How high does the indoor unit go?
At least 6 ft above the floor, in a room with a ceiling at least 7.3 ft high.
Does it need a drain?
Yes. Water from the indoor unit runs out through a drain hose. The hose goes through the same wall hole as the lines and has to run downhill.
Can I run it from my phone?
Yes. A Smart Controller Kit comes in the box. Once it is on your Wi-Fi, you can use the MRCOOL SmartHVAC app. The remote works too.
How often do I clean the filter?
Every two weeks. Lift the front panel, pull the filter out, wash it in warm water with mild soap and let it air dry out of the sun.
How heavy are the two units?
The indoor unit weighs about 40 lb and the outdoor unit about 150 lb.
How loud is the outdoor unit?
MRCOOL lists it at 60.5 dBA.
How is it different from the MRCOOL DIY 5th Gen?
The DIY 5th Gen comes with a 25 ft line set that is already filled with refrigerant and screws on with two wrenches. The Advantage uses copper lines with flare nuts and a vacuum pump. See the DIY 5th Gen systems.