Not what you were looking for? Find your system:
MRCOOL · DIY install
MRCOOL DIY 5th Gen Hyper Heat 12,000 BTU Ductless Mini-Split System (Indoor + Outdoor), 230V
Models: DIYHH-12-HP-C-230D25-O + DIY-12-HP-WMAH-230D25-O
- Cooling12,000 BTU
- Efficiency23.5 SEER2
- Heating10 HSPF2
- Power208-240V
- Install it yourself: the 25 ft line set comes pre-charged, so no vacuum pump or gauges
- 12,000 BTU heating and cooling for up to 550 sq ft
- Ductless: heats and cools one room with no ductwork to install
- Hyper Heat: keeps heating down to -22°F outdoors
- 23.5 SEER2 efficiency to keep power bills down
In stock
Free shipping · Ships in 1–2 business days
Secure checkout through Shopify
- Authorized MRCOOL dealer
- Licensed HVAC contractor
- Free shipping
- 30-day returns
- Free cancellation before it ships
Authorized MRCOOL dealer. You get new, genuine MRCOOL equipment with the full MRCOOL warranty. A licensed HVAC pro answers your texts.
About usRun by a licensed HVAC contractor. Text our team your sizing or install questions, Monday to Friday, 8 AM to 5 PM Central.
About usThis ships free. Orders under $300 ship for $19.95. You get tracking by email when it ships.
Shipping details30-day returns. Ask within 30 days of delivery. Returns ship back by carrier from your home. Send it back unopened for a refund, minus a 15% restocking fee. If it arrives damaged, broken or wrong, there is no fee and we pay the return shipping.
Return policyFree cancellation. Cancel before your order ships and you pay nothing.
Return policyAdd to your orderChecked to fit this system
-
MRCOOL Care Kit (MMCK01) Coil cleaning kit for MRCOOL mini-splits$79.99
Product overview
About this system
The MRCOOL DIY 5th Gen Hyper Heat 12,000 BTU system is a single-zone ductless heat pump that heats and cools one room or open area of up to 550 sq ft. It runs on 230V power and is rated 23.5 SEER2 and 10 HSPF2. The Hyper Heat outdoor unit keeps heating down to -22°F and cools in outdoor heat up to 122°F, which makes it a strong fit for cold-climate homes.
Built for do-it-yourself installation
The DIY 5th Gen series is designed for homeowner installation. Each system includes a 25 ft line set pre-charged with refrigerant and the DIYPRO armored cable, which connects the outdoor unit to the indoor unit and carries both power and communication between them. Because the cable is armored, it needs no separate conduit. The outdoor unit is powered by its own dedicated circuit.
Quiet operation and smart controls
The indoor unit runs as quietly as 18 dB(A) in Silent mode. Control the system with the included remote, the MRCOOL SmartHVAC app, Amazon Alexa or Google Assistant. A Gold Fin coating helps protect the outdoor coil from corrosion, and auto restart resumes operation after a power outage.
Warranty
MRCOOL backs this system with a 5-year parts warranty and a 7-year compressor warranty.
Need to heat and cool more than one room? Build a multi-room system.
Buying from Cool Air Depot
- Authorized MRCOOL dealerNew equipment with the full MRCOOL factory warranty.
- Free shippingThis item ships free.
- 30-day returnsRequest a return within 30 days of delivery, or cancel free before your order ships. Return policy
- Licensed HVAC supportText a pro at (479) 488-3576, Monday to Friday, 8 AM to 5 PM Central.
What's included
What's in the box
In the box
- Wall-mounted indoor unitDIY-12-HP-WMAH-230D25-O, with remote control
- Hyper Heat outdoor unitDIYHH-12-HP-C-230D25-O, heat pump condenser that keeps heating down to -22°F
- 25 ft Quick Connect line setPre-charged with R-454B refrigerant
- DIYPRO cableRuns between the outdoor and indoor units and carries power and communication
Specifications
Specs
Capacity
| Cooling capacity (Btu/h) | 12000 |
|---|---|
| Heating capacity (Btu/h) | 12000 |
| SEER2 | 23.5 |
| EER2 | 12.8 |
| HSPF2-4 | 10 |
| HSPF2-5 | 8 |
| Max coverage area (sq ft, ideal) | Up to 550 |
Noise
| Indoor dB(A) Turbo/Hi/Mi/Lo/Si | 45.5/40/34/22.5/18 |
|---|---|
| Outdoor dB(A) | 56.5 |
Operating
| Operating range | -22 F to 122 F |
|---|
Refrigerant
| Type | R-454B |
|---|---|
| Factory charge (oz) | 32.1 |
Electrical
| Power supply | 208/230V, 60 Hz, 1 Ph |
|---|---|
| Outdoor MCA (A) | 15 |
| Outdoor max fuse (A) | 15 |
Dimensions
| Indoor net WxDxH (in) | 31.57 x 7.44 x 11.69 |
|---|---|
| Indoor packing WxDxH (in) | 36.02 x 16.34 x 14.37 |
Weight
| Indoor net/gross (lb) | 24.47 / 35.05 |
|---|
Dimensions
| Outdoor net WxDxH (in) | 31.69 x 12.99 x 21.81 |
|---|---|
| Outdoor packing WxDxH (in) | 36.02 x 14.57 x 24.21 |
Weight
| Outdoor net/gross (lb) | 72.31 / 79.59 |
|---|
Piping
| Liquid / gas (in) | 1/4 / 3/8 |
|---|---|
| Included line set length | Brochure 25 ft nominal; Install Manual standard 24.6 ft |
| Standard pipe length ft | 24.6 |
| Max pipe length ft | 75 |
| Max elevation ft | 49.2 |
Figures come from MRCOOL's spec sheet, installation manual and AHRI certificate for this model. MRCOOL notes that spec sheet figures may change during production.
Installation
How a DIY install works
- 1Pick the spots
Follow the manual for indoor unit height, ceiling height, minimum room area and clearances around both units.
- 2Mount the units
Mount the indoor unit as the manual shows, and bolt the outdoor unit to a pad or wall bracket.
- 3Connect the Quick Connect line set
Thread each fitting by hand and tighten it with two wrenches. There's no vacuuming and no refrigerant to add. Check every joint with leak-detection spray.
- 4Open the valves
Open the outdoor unit's valves with a 5 mm Allen key, as the manual shows.
- 5Power and first start
Connect the DIYPRO cable and wire the power circuit to local code.
Power and tools
Electrical
- Power supply
- 208/230V
- Minimum circuit ampacity
- 15 A
- Maximum breaker or fuse
- 15 A
Warranty
MRCOOL's factory warranty
Covered
- Starts on your proof-of-purchase date. No registration is needed.
- Parts include the remote, the Wi-Fi dongle, the pre-charged line sets and the parts inside the indoor and outdoor units (the compressor has its own 7-year term).
Warranty exclusions
- Labor, shipping and refrigerant costs
- Damage from an install that doesn't follow the manual, local codes or permits
- A unit moved from its first install address
Summary of MRCOOL's limited warranty for the 5th Gen DIY series (rev. 07.03.25). The PDF below is the full terms. MRCOOL may ask for a licensed HVAC technician to diagnose a problem before approving a claim. Claims go to MRCOOL at (270) 366-0457 or support@mrcool.com.
Documents
Manuals and documents
Install and use
Specs and ratings
Warranty
Check the ratings yourself: enter AHRI reference number 216032549, date 09-18-2025 and certificate number 134026864965267520 at ahridirectory.org.
FAQ
Questions people ask
Still have a question? A licensed HVAC pro answers texts Monday to Friday, 8 AM to 5 PM Central.
Text a pro: (479) 488-3576Is a line set included?
Yes. The system comes with a 25 ft Quick Connect line set, pre-charged with R-454B, and the DIYPRO cable.
Can I install it myself?
Yes, for the mechanical work. The line set comes charged with refrigerant and connects with wrenches, so there's no vacuum pump or gauges. Electrical work is to be done to local code.
How long can the line run be?
MRCOOL lists up to 75 ft of line and 49.2 ft of height difference.
How big a space will it handle?
MRCOOL rates it for up to 550 sq ft.
What's the warranty?
MRCOOL covers parts, including the pre-charged line set, for 5 years and the compressor for 7 years from your proof-of-purchase date, with no registration needed. See the warranty section above for details.
See every size and series
Compare this system with other MRCOOL sizes and series, or answer four quick questions to see every match.
Pictures
See the MRCOOL DIY Hyper Heat up close
8 things to know





This one goes on the wall. Want it in the ceiling? See the 12,000 BTU Hyper Heat with the OuttaSight ceiling cassette.
Pictures are from MRCOOL.
Watch MRCOOL's DIY install guide (6 minutes)
MRCOOL's own install video for its DIY wall units. It goes from the wall plate to the first start. The Hyper Heat uses the same wall unit, line set and cable.
Can you put it in yourself? Yes. MRCOOL made the DIY Hyper Heat for do-it-yourself install. The line set comes filled with refrigerant and screws on with two wrenches. You do not need a vacuum pump, gauges or a refrigerant license.
MRCOOL DIY Hyper Heat 12,000 BTU installation, step by step
- Put up the wall plate. Use the paper template to mark the screw holes. Make the plate level and screw it on. Keep the indoor unit at least 6 ft above the floor, 5.9 inches below the ceiling and 4.72 inches from each side wall.
- Drill the wall hole. Drill one 3.54 inch hole through the wall. Tilt it down a little toward the outside so water runs out. Slide in the plastic wall sleeve.
- Get the lines ready. Gently bend the copper lines on the indoor unit so they point out the back. Bundle them with the drain hose and the cable.
- Hang the indoor unit. Push the bundle through the hole. Hook the unit on the top of the plate and press the bottom in. Get a helper for the lift.
- Plug in the Smart Controller. It is a small USB stick. Plug it into the indoor unit the way its sheet shows.
- Set the outdoor unit. Put it on a level pad or a wall bracket and bolt it down with M10 bolts. Leave room for air around it. Where snow piles up, set it up off the ground.
- Hook up the Quick Connect lines. Unroll the line set gently. Do not cut it. Start each fitting by hand so it goes on straight. Hold the nut marked 1 still and turn the nut marked 2 until it is snug.
- Open the two valves. Take off each valve cap with a 19 mm wrench. Turn each valve to the left with the 5 mm Allen key until it stops. Put the caps back on tight.
- Check for leaks. Brush or spray soapy water on every fitting. Bubbles mean a leak.
- Do the wiring. Turn the breaker off first. The DIYPRO cable from the indoor unit and the power from your home both connect at the outdoor unit. Match each wire to the diagram.
- Turn it on and test it. Run Cool, then Heat. MRCOOL says to test it for at least 30 minutes and to check the fittings for leaks again while it runs.
Tools you need
- Drill and a 3.54 inch core drill or hole saw
- Open-end wrenches: 19, 22, 24 and 26 mm. Or two adjustable wrenches
- 5 mm Allen key (one comes in the box)
- Phillips screwdriver
- Level, tape measure and stud finder
- Leak spray or soapy water
- Gloves and eye protection
Before you start
- Power: the outdoor unit is wired to its own 208/230V circuit. The biggest breaker it can use is 15 amps. If your home does not have that circuit yet, have an electrician add it.
- Line set: it is 25 ft long. Do not cut it. Keep every bend wider than 4 inches. Need more length? See line sets and couplers.
- The fittings seal one time. Pick both spots before you hook them up.
- Snow: keep snow and ice away from the outdoor unit so air can move through it.
- Weight: the indoor unit weighs about 24 lb and the outdoor unit about 72 lb. Get a helper.
These steps follow MRCOOL's DIY Hyper Heat installation manual (version date January 8, 2026). Read the full manual before you start. It is under Manuals on this page.
Day to day
Using the DIY Hyper Heat
Controls
- Five modes: Auto, Cool, Heat, Dry and Fan.
- Follow Me: the remote reads the temperature where you are and tells the unit.
- Turbo: the strongest fan, to heat or cool the room fast.
- Silence and Sleep: run quieter and use less power at night.
- Timer: turn on or off in up to 24 hours.
- FP: holds an empty room at 46 degrees so it does not freeze.
Set up the phone app
- A Smart Controller Kit comes in the box.
- Plug it into the indoor unit (step 5 above).
- Get the MRCOOL SmartHVAC app on your iPhone or Android phone.
- Follow the sheet in the kit to add your unit to your Wi-Fi.
- It also works with Alexa and Google Assistant.
Care
- Clean the filter every two weeks. Lift the front panel, pull the filter out, wash it in warm water with mild soap and let it air dry out of the sun.
- Active Clean: press Clean on the remote. The unit cleans itself and shuts off in 20 to 45 minutes.
- Auto restart: after a power outage it comes back on by itself.
- In winter, keep snow and ice off the outdoor unit.
How cold can it be outside and still heat?
MRCOOL rates the Hyper Heat to keep heating down to 22 below zero (-22 F). It cools in outdoor heat up to 122 F.
What size hole do I drill?
One hole, 3.54 inches wide. Tilt it down a little toward the outside so water drains out. The plastic wall sleeve comes in the box.
Can I cut the line set if it is too long?
No. It is filled with refrigerant. Coil the extra length behind the outdoor unit and keep every bend wider than 4 inches.
Can I take the fittings apart and use them again?
MRCOOL says the line set is made to be put in one time. Pick both spots before you hook it up.
Can I plug it into a wall outlet?
No. The outdoor unit is wired to its own 208/230V circuit with a breaker up to 15 amps. If your home does not have that circuit yet, have an electrician add it.
How high does the indoor unit go?
At least 6 ft above the floor, in a room with a ceiling at least 7.3 ft high. Leave 5.9 inches above it and 4.72 inches on each side.
What tools do I need?
A drill with a 3.54 inch hole saw, open-end or adjustable wrenches, a 5 mm Allen key, a Phillips screwdriver, a level, a tape measure, and leak spray or soapy water.
What do I do about snow?
Set the outdoor unit up off the ground where snow piles up. Keep snow and ice away from it so air can move through it.
Can I get it with a ceiling unit instead of a wall unit?
Yes. The same outdoor unit comes with the OuttaSight ceiling cassette, which sits in the ceiling between the joists.
Does it need a drain?
Yes. Water from the indoor unit runs out through a drain hose. The hose goes through the same wall hole as the lines and has to run downhill.
How often do I clean the filter?
Every two weeks. Lift the front panel, pull the filter out, wash it in warm water with mild soap and let it air dry out of the sun.
How heavy are the two units?
The indoor unit weighs about 24 lb and the outdoor unit about 72 lb. Get a helper for the lifts.
Does it come back on after the power goes out?
Yes. It has auto restart, so it turns back on by itself when the power returns.
What refrigerant does it use?
R-454B. The outdoor unit and the line set come filled at the factory. You do not add any.
Best for: The coldest places, where it drops far below zero.
Systems for a room up to 550 sq ft
You can put these in yourself. Tap one to see it.
MRCOOL DIY Select
$1,399Best for: Warm places with mild winters, like the South. Costs the least.See this one →See it in black →
MRCOOL DIY Easy Pro
$1,599Best for: A lower power bill and a longer warranty. Heats in cold winters too.See this one →
MRCOOL Easy Pro 5th Gen
$1,649Best for: Mild winters, when the outside unit has to sit a little farther from the room.See this one →
MRCOOL DIY 5th Gen
$1,759Best for: Places with cold winters. Also when the outside unit has to sit far from the room.See this one →
MRCOOL DIY 5th Gen Hyper Heat
$2,532Best for: The coldest places, where it drops far below zero.You are looking at this oneLonger pre-charged line setOptional, sold separately