Not what you were looking for? Find your system:



MRCOOL DIY 5th Gen
MRCOOL DIY 5th Gen 18,000 BTU Outdoor Unit Only, 230V (Indoor Unit Sold Separately) (DIY-18-HP-C-230D25-O)
Model DIY-18-HP-C-230D25-O
Outdoor unit only. It needs the matching indoor unit to heat and cool. The complete system costs $600 less than buying both units one at a time.
Get the complete system: indoor + outdoor$2,309Already have the indoor unit? Add this one to your cart below.
- Capacity18,000 BTU
- Power208-240V
- Max breaker20 A
- Sound58.5 dB(A)
- Weight93.48 lb
- Install it yourself: the 25 ft line set comes pre-charged, so no vacuum pump or gauges
- 18,000 BTU heat pump for heating and cooling
- 22.5 SEER2 efficiency to keep power bills down
- Control it with the remote, your phone, Alexa or Google Assistant
- Pairs with the matching indoor unit, or get both as a complete system
In stock
Free shipping · Ships in 1–2 business days
Secure checkout through Shopify
- Authorized MRCOOL dealer
- Licensed HVAC contractor
- Free shipping
- 30-day returns
- Free cancellation before it ships
Authorized MRCOOL dealer. You get new, genuine MRCOOL equipment with the full MRCOOL warranty. A licensed HVAC pro answers your texts.
About usRun by a licensed HVAC contractor. Text our team your sizing or install questions, Monday to Friday, 8 AM to 5 PM Central.
About usThis ships free. Orders under $300 ship for $19.95. You get tracking by email when it ships.
Shipping details30-day returns. Ask within 30 days of delivery. Returns ship back by carrier from your home. Send it back unopened for a refund, minus a 15% restocking fee. If it arrives damaged, broken or wrong, there is no fee and we pay the return shipping.
Return policyFree cancellation. Cancel before your order ships and you pay nothing.
Return policyAdd to your orderChecked to fit this unit
-
MRCOOL Condenser Wall Bracket for 9K, 12K and 18K Systems (MB176) MRCOOL makes this bracket for its 9K, 12K and 18K outdoor units. This outdoor unit weighs 93.5 lb.$77.00
-
MRCOOL Condenser Riser, 6 in Rubber, Set of Two (H600-B) Lifts the outdoor unit 6 in off the ground. The unit's feet are 26.1 in apart.$59.00
-
MRCOOL DIY 5th Gen 25 ft Line Set 1/4 x 1/2 in with DIY Pro Cable, R-454B (for 9K, 12K, and 18K Indoor Units) (DIY25-1412C-O) 25 ft with DIY Pro Cable. Same R-454B refrigerant and 1/4 x 1/2 in line size as this unit.$436.00
-
MRCOOL DIY 5th Gen 35 ft Line Set 1/4 x 1/2 in with DIY Pro Cable, R-454B (for 9K, 12K, and 18K Indoor Units) (DIY35-1412C-O) 35 ft with DIY Pro Cable. Same R-454B refrigerant and 1/4 x 1/2 in line size as this unit.$510.00
-
MRCOOL DIY 5th Gen 50 ft Line Set 1/4 x 1/2 in with DIY Pro Cable, R-454B (for 9K, 12K, and 18K Indoor Units) (DIY50-1412C-O) 50 ft with DIY Pro Cable. Same R-454B refrigerant and 1/4 x 1/2 in line size as this unit.$599.00
-
MRCOOL DIY Line Set Coupler Kit with 75 ft DIY Pro Cable for 6k, 9k, 12k, and 18k Units (DIYCOUPLER-1412K75C) Joins two 1/4 x 1/2 in line sets for a longer run. Comes with 75 ft of DIY Pro Cable. Keep the total line at 75 ft or less.$427.00
-
MRCOOL LineGuard 4.5 in Line Set Cover Kit, 12 ft, White (MLG450) 12 ft cover that hides the line set, cable and drain on the outside wall. White.$132.00
-
MRCOOL LineGuard 4.5 in Line Set Cover Kit, 12 ft, Gray (MLG450-G-01) 12 ft cover that hides the line set, cable and drain on the outside wall. Gray.$133.00
-
MRCOOL LineGuard 4.5 in Line Set Cover Kit, 12 ft, Tan (MLG450-T-01) 12 ft cover that hides the line set, cable and drain on the outside wall. Tan.$133.00
This is the outdoor unit with its 25 ft pre-charged line set. It pairs with the DIY-18-HP-WMAH-230D25-O indoor unit. Want both? Get the complete 18K system.
Questions? Text a licensed HVAC pro. (479) 488-3576 · Mon to Fri, 8 AM to 5 PM CentralProduct overview
About this unit
The MRCOOL DIY 5th Gen 18,000 BTU outdoor unit (model DIY-18-HP-C-230D25-O) is the heat pump condenser for a single-zone ductless system. It runs on 208/230V power and is sold without an indoor unit. Paired with the matching indoor unit, the system is rated 22.5 SEER2 and 11.5 HSPF2 and covers up to 800 sq ft. It keeps heating down to -13°F and cools in outdoor heat up to 122°F.
What you need to complete the system
Add the matching indoor unit: DIY-18-HP-WMAH-230D25-O. It ships with a 25 ft line set (1/4 x 1/2 in) that is pre-charged with R-454B refrigerant and fitted with Quick Connect couplings.
Electrical and sound
The outdoor unit needs its own dedicated circuit with a 20 A maximum breaker. It runs at 58.5 dB(A). A Gold Fin coating helps protect the coil from corrosion.
Buying from Cool Air Depot
- Authorized MRCOOL dealerNew equipment with the full MRCOOL factory warranty.
- Free shippingThis item ships free.
- 30-day returnsRequest a return within 30 days of delivery, or cancel free before your order ships. Return policy
- Licensed HVAC supportText a pro at (479) 488-3576, Monday to Friday, 8 AM to 5 PM Central.
What's included
What's in the box
In the box
- Outdoor unitDIY-18-HP-C-230D25-O
- 25 ft Quick Connect line setPre-charged with R-454B refrigerant, 1/4 x 1/2 in
Not included: the indoor unit.
Specifications
Specs for this outdoor unit
- SystemDIY-18-HP-WM-230D25-O
- Indoor unitDIY-18-HP-WMAH-230D25-O
- Outdoor unitDIY-18-HP-C-230D25-O
Outdoor unit
| Model | DIY-18-HP-C-230D25-O |
|---|---|
| Size (W x D x H) | 35.04 x 13.46 x 26.50 in |
| Weight (unit / boxed) | 93.48 / 114.20 lb |
| Box size (W x D x H) | 40.55 x 18.11 x 29.53 in |
| Mounting foot spacing | 26.1 x 13.9 in, M10 bolts |
| Sound | 58.5 dB(A) |
Electrical
| Power supply | 208-230V, 1-phase, 60 Hz |
|---|---|
| Minimum circuit ampacity | 18 A |
| Maximum breaker or fuse | 20 A |
| Minimum wire size (manual's chart) | 12 AWG |
Refrigerant and line set
| Refrigerant | R-454B |
|---|---|
| Factory charge | 44.80 oz |
| Pipe sizes (liquid / gas) | 1/4 in / 1/2 in |
| Maximum line length | 75 ft |
| Maximum height difference between units | 65.6 ft |
Paired with DIY-18-HP-WMAH-230D25-O
| Cooling capacity (at 95°F) | 18,000 BTU/h |
|---|---|
| Heating capacity (at 47°F) | 18,000 BTU/h |
| SEER2 | 22.5 |
| EER2 | 13.7 |
| HSPF2 (Region IV) | 11.5 |
| Room size, ideal conditions | Up to 800 sq ft |
| HSPF2 (Region V) | 8.5 |
| Outdoor temperature range, cooling | -13°F to 122°F |
| Outdoor temperature range, heating | -13°F to 75°F |
Paired ratings are from AHRI certificate 216032545 for this outdoor unit with the DIY-18-HP-WMAH-230D25-O indoor unit. Other figures come from MRCOOL's DIY 5th Gen single-zone spec sheet (V.06.24.26) and installation manual. MRCOOL notes that spec sheet figures may change during production.
Installation
How a DIY install works
- 1Pick the spot
A level pad on the ground or a wall bracket, with the clearances the manual shows around the unit.
- 2Fit the drain joint and mount it
Fit the drain joint to the bottom of the unit, then bolt it down with M10 bolts. The mounting feet are 26.1 x 13.9 in apart.
- 3Connect the line set
Thread each Quick Connect fitting by hand, then tighten it with two wrenches. There's no vacuuming and no refrigerant to add. Check every joint with leak-detection spray or soapy water.
- 4Open the valves
Remove each valve cover with a 19 mm wrench, open the valve counterclockwise with a 5 mm Allen key until it stops, then put the cover back on tight.
- 5Power
The outdoor unit needs its own 208-230V circuit with a breaker up to 20 A.
Power and tools
Electrical
- Power supply
- 208-230V, 1-phase, 60 Hz
- Minimum circuit ampacity
- 18 A
- Maximum breaker or fuse
- 20 A
- Minimum wire size (manual's chart)
- 12 AWG.
Tools you'll need
- Open-end wrenches: 19 mm, 22 mm, 24 mm and 26 mm, or two adjustable wrenches (an HVAC torque wrench is best if you have one)
- 5 mm Allen key for the valves
- Drill and masonry bit for the M10 anchor bolts
- Leak-detection spray or soapy water
- Gloves and eye protection
Warranty
MRCOOL's factory warranty
Covered
- Starts on your proof-of-purchase date. No registration is needed.
- Parts include the remote, the Wi-Fi dongle, the pre-charged line sets and the parts inside the indoor and outdoor units (the compressor has its own 7-year term).
- Repaired or replaced parts are covered for the rest of the original term, or 30 days, whichever is longer.
Warranty exclusions
- Labor, shipping and refrigerant costs
- Damage from an install that doesn't follow the manual, local codes or permits
- A unit moved from its first install address, or installed outside the USA and Canada
Summary of MRCOOL's limited warranty for the 5th Generation DIY series (rev. 07.03.25). The PDF below is the full terms. MRCOOL may ask for a licensed HVAC technician to diagnose a problem before approving a claim. Claims go to MRCOOL at (270) 366-0457 or support@mrcool.com.
Documents
Manuals and documents
Install and use
Specs and ratings
Check the ratings yourself: enter AHRI reference number 216032545, date 02-18-2025 and certificate number 133843669430084426 at ahridirectory.org.
FAQ
Questions people ask
Still have a question? A licensed HVAC pro answers texts Monday to Friday, 8 AM to 5 PM Central.
Text a pro: (479) 488-3576What does it pair with?
MRCOOL's AHRI certificate 216032545 rates this outdoor unit with the DIY-18-HP-WMAH-230D25-O indoor unit. That indoor unit is available on its own, or get both together in the complete 18K system.
Does it come with a line set?
Yes. It comes with a 25 ft Quick Connect line set, pre-charged with R-454B, 1/4 x 1/2 in. The DIYPRO cable comes with the indoor unit.
How long can the line run be?
MRCOOL's installation manual allows up to 75 ft of line and up to 65.6 ft of height difference for this size.
How is it powered?
It's hardwired to its own 208-230V circuit with a breaker up to 20 A.
Where does the outdoor unit go?
On a level pad on the ground or on a wall bracket, bolted down with M10 bolts. The outdoor unit weighs about 93 lb.
Does it heat in cold weather?
Yes. MRCOOL's manual lists a heating range down to -13°F outdoors.
What's the warranty?
MRCOOL covers parts, including the pre-charged line set, for 5 years and the compressor for 7 years from your proof-of-purchase date, with no registration needed. See the warranty section above for details.
Pictures and video
See the MRCOOL DIY 5th Gen up close
The DIY 5th Gen in 25 seconds
A short video from MRCOOL. It shows the outdoor unit and what is new in the 5th Gen, like R-454B refrigerant.
8 things to know








This is the outdoor unit by itself. It pairs with the 18,000 BTU indoor unit. Want both in one order? See the complete 18,000 BTU system.
Pictures and video are from MRCOOL. They show the complete system.
Watch MRCOOL install one (6 minutes)
MRCOOL's own install video. It walks through the same 10 steps as the quick start guide in the box, from the wall plate to the first start.
Can you put it in yourself? Yes. MRCOOL made the DIY 5th Gen for do-it-yourself install. The line set comes filled with refrigerant and screws on with two wrenches. You do not need a vacuum pump, gauges or a refrigerant license.
The whole 18,000 BTU DIY 5th Gen install, step by step
- Put up the wall plate.0:00 Take the metal plate off the back of the indoor unit. Use the paper template to mark the screw holes on wall studs. Make the plate level and screw it on. Keep the unit at least 6 ft above the floor.
- Drill the wall hole.1:04 Drill one 3.54 inch (90 mm) hole through the wall. Tilt it down a little toward the outside so water runs out. Slide in the plastic wall sleeve.
- Get the lines ready.1:26 Gently bend the copper lines on the indoor unit so they point straight back. Bundle them with the drain hose. Keep the drain hose on the bottom.
- Hang the indoor unit.1:40 Push the bundle through the hole. Hook the unit on the top of the plate. Press the bottom in until it clicks. Get a helper for the lift.
- Plug in the USB smart dongle.2:03 Open the small USB cover on the indoor unit with a screwdriver. Plug in the dongle and snap the cover back on.
- Set the outdoor unit.2:27 Put it on a level pad or a wall bracket and bolt it down. Leave room for air around it. Unroll only as much line set as you need.
- Hook up the Quick Connect lines.2:54 Pull off the plastic seals. Start each fitting by hand so it goes on straight. Hold one wrench still and turn only the nut marked 2 with the other. No tape and no pipe dope.
- Open the two valves.3:46 Take off each brass cap with a 19 mm wrench. Turn each valve to the left with the 5 mm Allen key until it stops. Put the caps back on tight. Check every fitting with leak spray or soapy water. Bubbles mean a leak.
- Do the wiring.4:53 Turn the breaker off first. Open the wiring cover on the outdoor unit. The DIYPRO cable from the indoor unit and the power from your home both connect here. Match each wire to the diagram inside the cover. Tighten the screws and close the cover.
- Turn it on and test it.5:45 Put the batteries in the remote and turn the power on. Run Cool and Heat. MRCOOL says to test it for at least 30 minutes and to check the fittings for leaks again while it runs.
Tools you need
- Drill and a 3.5 inch (90 mm) hole saw
- Two adjustable wrenches, or open-end wrenches (19, 22, 24 and 26 mm)
- 5 mm Allen key (one comes in the box)
- Phillips screwdriver
- Level, tape measure and stud finder
- Leak spray or soapy water
- Gloves and eye protection
Before you start
- Power: the outdoor unit is wired to its own 208-230V circuit. The biggest breaker it can use is 20 amps. If your home does not have that circuit yet, have an electrician add it.
- Line set: it is 25 ft long. Do not cut it. Coil the extra and lay it flat behind the outdoor unit.
- Bends: keep every bend wider than a 4 inch radius so the copper does not kink.
- The fittings seal one time. Pick both spots before you hook them up.
- Room: the room must be at least 12 sq ft. The ceiling must be at least 7.3 ft high.
- Weight: the indoor unit weighs about 35 lb and the outdoor unit about 93 lb. Get a helper.
These steps follow MRCOOL's quick start guide and its installation manual (version date August 5, 2026). The times show where each step starts in the video. Read the quick start guide (PDF) and the full manual (PDF) before you start.
Day to day
Using the DIY 5th Gen
Controls
- Five modes: Auto, Cool, Heat, Dry and Fan.
- Follow Me: the remote reads the temperature where you are and tells the unit.
- Turbo: the strongest fan, to heat or cool the room fast.
- Silence and Sleep: run quieter and use less power at night.
- Timer: turn on or off in up to 24 hours.
Set up the phone app
- The smart kit is a small USB dongle. It comes in the box with the indoor unit.
- Plug it into the indoor unit (step 5 above).
- Get the MRCOOL SmartHVAC app on your iPhone or Android phone.
- Follow the setup sheet that comes with the kit to add your unit.
- After that, you can use Amazon Alexa or Google Assistant too.
Care
- Clean the filter every two weeks. Lift the front panel, pull the filter out, wash it in warm water with mild soap and let it air dry.
- Active Clean: press Clean on the remote. The unit cleans itself and shuts off in 20 to 45 minutes.
- Long break: clean the filters, run Fan until the unit is dry, then turn it off and cut the power.
- Cools when it is -13°F to 122°F outside. Heats when it is -13°F to 75°F outside.
Compare
Pick your size and see how it compares
The five DIY 5th Gen outdoor units
| Size | Room size | Power | Biggest breaker | SEER2 | Quiet as |
|---|---|---|---|---|---|
| 9,000 BTU | Up to 400 sq ft | 115V | 20 amps | 23.6 | 18 dB(A) |
| 12,000 BTU | Up to 550 sq ft | 115V | 20 amps | 23.5 | 18 dB(A) |
| 18,000 BTUThis one | Up to 800 sq ft | 208-230V | 20 amps | 22.5 | 19 dB(A) |
| 24,000 BTU | Up to 1,050 sq ft | 208-230V | 25 amps | 22.7 | 20 dB(A) |
| 36,000 BTU | Up to 1,550 sq ft | 208-230V | 35 amps | 18 | 27.5 dB(A) |
Swipe sideways to see it all.
DIY 5th Gen vs. window AC, portable AC and a regular mini split
| DIY 5th Gen | Window AC | Portable AC | Regular mini split | |
|---|---|---|---|---|
| Heats and cools | Yes, both | Most only cool | Most only cool | Yes, both |
| Who puts it in | You | You | You | Most need an HVAC company |
| Tools for the lines | Two wrenches | None | None | Vacuum pump and gauges |
| Uses your window | No | Yes | Yes, for the hose | No |
| Stays up all year | Yes | Often comes out in winter | Often put away in winter | Yes |
| Noise in the room | As low as 19 dB(A) | Compressor sits in the window | Compressor sits in the room | Low. Compressor is outside |
| Power | Its own 208-230V circuit | Wall outlet | Wall outlet | Its own circuit |
Swipe sideways to see all four.
Not sure which size fits your room? Use our one-room picker.
What size hole do I drill?
One hole, 3.54 inches (90 mm) wide. Tilt it down a little toward the outside so water drains out. The plastic wall sleeve comes in the box with the indoor unit.
Can I cut the line set if it is too long?
No. It is filled with refrigerant. Coil the extra and lay it flat behind the outdoor unit.
Can I take the fittings apart and use them again?
MRCOOL says the Quick Connect fittings are made to go on one time. Taking them apart can hurt the seal and the warranty. Pick both spots before you hook them up.
Can I plug it into a wall outlet?
No. The outdoor unit is wired to its own 208-230V circuit with a breaker up to 20 amps. If your home does not have that circuit yet, have an electrician add it.
How high does the indoor unit go?
At least 6 ft above the floor. Leave 5.9 inches open above it and 4.72 inches open on each side.
What tools do I need?
A drill with a 3.5 inch hole saw, two adjustable wrenches, a 5 mm Allen key, a Phillips screwdriver, a level, a tape measure, and leak spray or soapy water.
Does it need a drain?
Yes. Water from the indoor unit runs out through a drain hose. The hose goes through the same wall hole as the lines. It has to run downhill with no kinks.
How often do I clean the filter?
Every two weeks. Lift the front panel, pull the filter out, wash it in warm water with mild soap and let it air dry.
How heavy are the two units?
The indoor unit weighs about 35 lb and the outdoor unit about 93 lb. Get a helper for the lifts.
How loud is it?
Indoors it runs as low as 19 dB(A) on Silent. The outdoor unit is rated 58.5 dB(A).
What refrigerant does it use?
R-454B. The outdoor unit and the line set come filled at the factory. You do not add any.