Not what you were looking for? Find your system:




MRCOOL DIY 5th Gen
MRCOOL DIY 5th Gen 36,000 BTU Indoor Unit Only, 230V (Outdoor Unit Sold Separately) (DIY-36-HP-WMAH-230D25-O)
Model DIY-36-HP-WMAH-230D25-O
Indoor unit only. It needs the matching outdoor unit to heat and cool. The complete system costs $600 less than buying both units one at a time.
Get the complete system: indoor + outdoor$3,169Already have the outdoor unit? Add this one to your cart below.
- Capacity36,000 BTU
- Power208-240V
- Sound27.5 dB(A)
- Weight48.72 lb
- Width49.57 in
- Made for do-it-yourself installation with MRCOOL's pre-charged Quick Connect line sets
- 36,000 BTU heating and cooling for up to 1,550 sq ft
- Ductless: heats and cools one room with no ductwork to install
- Control it with the remote, your phone, Alexa or Google Assistant
- Pairs with the matching outdoor unit, or get both as a complete system
In stock
Free shipping · Ships in 1–2 business days
Secure checkout through Shopify
- Authorized MRCOOL dealer
- Licensed HVAC contractor
- Free shipping
- 30-day returns
- Free cancellation before it ships
Authorized MRCOOL dealer. You get new, genuine MRCOOL equipment with the full MRCOOL warranty. A licensed HVAC pro answers your texts.
About usRun by a licensed HVAC contractor. Text our team your sizing or install questions, Monday to Friday, 8 AM to 5 PM Central.
About usThis ships free. Orders under $300 ship for $19.95. You get tracking by email when it ships.
Shipping details30-day returns. Ask within 30 days of delivery. Returns ship back by carrier from your home. Send it back unopened for a refund, minus a 15% restocking fee. If it arrives damaged, broken or wrong, there is no fee and we pay the return shipping.
Return policyFree cancellation. Cancel before your order ships and you pay nothing.
Return policyAdd to your orderChecked to fit this unit
-
MRCOOL DIY 5th Gen 25 ft Line Set 3/8 x 5/8 in with DIY Pro Cable, R-454B (for 24K and 36K Indoor Units) (DIY25-3858C-O) 25 ft with DIY Pro Cable. Same R-454B refrigerant and 3/8 x 5/8 in line size as this unit.$613.00
-
MRCOOL DIY 5th Gen 35 ft Line Set 3/8 x 5/8 in with DIY Pro Cable, R-454B (for 24K and 36K Indoor Units) (DIY35-3858C-O) 35 ft with DIY Pro Cable. Same R-454B refrigerant and 3/8 x 5/8 in line size as this unit.$565.00
-
MRCOOL DIY 5th Gen 50 ft Line Set 3/8 x 5/8 in with DIY Pro Cable, R-454B (for 24K and 36K Indoor Units) (DIY50-3858C-O) 50 ft with DIY Pro Cable. Same R-454B refrigerant and 3/8 x 5/8 in line size as this unit.$662.00
-
MRCOOL DIY Line Set Coupler Kit with 75 ft DIY Pro Cable for 24k and 36k Units (DIYCOUPLER-3858K75C) Joins two 3/8 x 5/8 in line sets for a longer run. Comes with 75 ft of DIY Pro Cable. Keep the total line at 75 ft or less.$451.00
-
MRCOOL LineGuard 4.5 in Line Set Cover Kit, 12 ft, White (MLG450) 12 ft cover that hides the line set, cable and drain on the outside wall. White.$132.00
-
MRCOOL LineGuard 4.5 in Line Set Cover Kit, 12 ft, Gray (MLG450-G-01) 12 ft cover that hides the line set, cable and drain on the outside wall. Gray.$133.00
-
MRCOOL LineGuard 4.5 in Line Set Cover Kit, 12 ft, Tan (MLG450-T-01) 12 ft cover that hides the line set, cable and drain on the outside wall. Tan.$133.00
-
MRCOOL Smart Wi-Fi Mini-Stat for Ductless Mini-Splits (MST05) Wall-mounted smart control for MRCOOL ductless units.$114.00
This is the indoor unit with its DIYPRO cable, remote and install kit. It pairs with the DIY-36-HP-C-230D25-O outdoor unit. Want both? Get the complete 36K system.
Questions? Text a licensed HVAC pro. (479) 488-3576 · Mon to Fri, 8 AM to 5 PM CentralProduct overview
About this unit
The MRCOOL DIY 5th Gen 36,000 BTU indoor unit (model DIY-36-HP-WMAH-230D25-O) is a wall-mounted air handler for one room or open area of up to 1,550 sq ft. It runs on 208/230V power and is sold without an outdoor unit. Paired with the matching DIY 5th Gen 36,000 BTU outdoor unit (model DIY-36-HP-C-230D25-O), the system is rated 18 SEER2 and 8.5 HSPF2.
What you need to complete the system
Add the matching outdoor unit, model DIY-36-HP-C-230D25-O. It ships with a 25 ft line set that is pre-charged with R-454B refrigerant and fitted with Quick Connect couplings. It can also be one room of a DIY 5th Gen multi-zone system. Our multi-room builder matches the outdoor unit and line sets for you.
Features
The indoor unit runs as quietly as 27.5 dB(A) on its lowest fan setting. It comes with a remote control and a Smart Controller Kit for the MRCOOL SmartHVAC app.
Buying from Cool Air Depot
- Authorized MRCOOL dealerNew equipment with the full MRCOOL factory warranty.
- Free shippingThis item ships free.
- 30-day returnsRequest a return within 30 days of delivery, or cancel free before your order ships. Return policy
- Licensed HVAC supportText a pro at (479) 488-3576, Monday to Friday, 8 AM to 5 PM Central.
What's included
What's in the box
In the box
- Wall-mounted indoor unitDIY-36-HP-WMAH-230D25-O, with mounting plate, paper template, remote control and holder
- DIYPRO cableConnects the indoor unit to the outdoor unit
- Smart Controller KitFor control from a smartphone app
- Wall sleeve, drain pipe and insulationPlastic wall sleeve and cap, drain pipe, 2 insulation sleeves and tape
Not included: the outdoor unit (DIY-36-HP-C-230D25-O). The outdoor unit ships with the 25 ft line set.
Full packing list from MRCOOL's manual
| Part | Qty |
|---|---|
| Manuals (installation and remote) | 2 |
| AAA batteries | 2 |
| Mounting plate (metal) and cardboard template | 1 each |
| Remote control | 1 |
| Remote control holder | 1 |
| Screws for the remote control holder | 2 |
| Drain pipe | 1 |
| Insulation sleeves | 2 |
| Anchors and mounting plate screws | 5 to 8 each |
| Sound-absorbent pads | 2 |
| Seal | 1 |
| Smart Controller Kit | 1 |
| Drain joint | 1 |
| DIYPRO cable | 1 |
| Plastic wall sleeve and cap | 1 |
| Small filters | 2 |
| Allen wrench | 1 |
| Neoprene | 1 |
| Non-adhesive tape | 1 |
MRCOOL notes that the manual's drawings are for reference and the parts may look a little different.
Specifications
Specs for this indoor unit
- SystemDIY-36-HP-WM-230D25-O
- Indoor unitDIY-36-HP-WMAH-230D25-O
- Outdoor unitDIY-36-HP-C-230D25-O
Indoor unit
| Model | DIY-36-HP-WMAH-230D25-O |
|---|---|
| Size (W x D x H) | 49.57 x 11.10 x 14.25 in |
| Weight (unit / boxed) | 48.72 / 67.90 lb |
| Box size (W x D x H) | 53.94 x 18.74 x 16.57 in |
| Sound (turbo / high / medium / low / silent) | 55.5 / 49.5 / 43.5 / 38 / 27.5 dB(A) |
| Type | Wall-mounted |
Electrical
| Power supply | 208-230V, 1-phase, 60 Hz |
|---|
Connections
| Pipe sizes (liquid / gas) | 3/8 in / 5/8 in, Quick Connect |
|---|---|
| Refrigerant | R-454B |
Paired with DIY-36-HP-C-230D25-O
| Cooling capacity (at 95°F) | 36,000 BTU/h |
|---|---|
| Heating capacity (at 47°F) | 36,000 BTU/h |
| SEER2 | 18.0 |
| EER2 | 8.5 |
| HSPF2 (Region IV) | 8.5 |
| Room size, ideal conditions | Up to 1,550 sq ft |
Installation
| Indoor unit height | At least 6.0 ft above the floor |
|---|---|
| Ceiling height | At least 7.3 ft |
| Minimum room area (R-454B) | 106 sq ft with the indoor unit mounted 6.0 to 7.3 ft high (less when it is mounted higher; see the table in the manual) |
Paired ratings are from AHRI certificate 216032548 for this indoor unit with the DIY-36-HP-C-230D25-O outdoor unit. Other figures come from MRCOOL's DIY 5th Gen single-zone spec sheet (V.06.24.26) and installation manual. MRCOOL notes that spec sheet figures may change during production.
Installation
How a DIY install works
- 1Pick the spot
Mount the indoor unit at least 6 ft above the floor, in a room with a ceiling of at least 7.3 ft and at least 106 sq ft of floor area. Leave the clearances the manual shows.
- 2Mount the plate and drill the hole
Use the paper template, fix the metal mounting plate level on the wall and drill a 3.5 in hole for the line set, cable and drain. MRCOOL's manual says the piping should exit the indoor unit on the right-hand side when you face it.
- 3Hang the unit and run the drain
Hang the indoor unit on the mounting plate and route the drain pipe through the wall hole so water runs to the outside.
- 4Connect the line set
Thread each Quick Connect fitting by hand, then tighten it with two wrenches. There's no vacuuming and no refrigerant to add. Check every joint with leak-detection spray or soapy water.
Power and tools
Electrical
- Power supply
- 208-230V, 1-phase, 60 Hz
- Wiring
- MRCOOL's manual says the indoor unit arrives pre-wired from the factory.
Tools you'll need
- Drill and 3.5 in core drill for the wall hole
- Open-end wrenches: 19 mm, 24 mm, 26 mm, 29 mm and 31 mm, or two adjustable wrenches (an HVAC torque wrench is best if you have one)
- Level and a Phillips screwdriver
- Leak-detection spray or soapy water
- Gloves, eye protection and a dust mask
Warranty
MRCOOL's factory warranty
Covered
- Starts on your proof-of-purchase date. No registration is needed.
- Parts include the remote, the Wi-Fi dongle, the pre-charged line sets and the parts inside the indoor and outdoor units (the compressor has its own 7-year term).
- Repaired or replaced parts are covered for the rest of the original term, or 30 days, whichever is longer.
Warranty exclusions
- Labor, shipping and refrigerant costs
- Damage from an install that doesn't follow the manual, local codes or permits
- A unit moved from its first install address, or installed outside the USA and Canada
Summary of MRCOOL's limited warranty for the 5th Generation DIY series (rev. 07.03.25). The PDF below is the full terms. MRCOOL may ask for a licensed HVAC technician to diagnose a problem before approving a claim. Claims go to MRCOOL at (270) 366-0457 or support@mrcool.com.
Documents
Manuals and documents
Install and use
Specs and ratings
Check the ratings yourself: enter AHRI reference number 216032548, date 02-19-2025 and certificate number 133844506684118319 at ahridirectory.org.
FAQ
Questions people ask
Still have a question? A licensed HVAC pro answers texts Monday to Friday, 8 AM to 5 PM Central.
Text a pro: (479) 488-3576What does it pair with?
MRCOOL's AHRI certificate 216032548 rates this indoor unit with the DIY-36-HP-C-230D25-O outdoor unit. That outdoor unit is available on its own, or get both together in the complete 36K system.
What comes with it?
The indoor unit, the DIYPRO cable, the remote, the Smart Controller Kit and the mounting and drain parts. The 25 ft pre-charged line set comes with the outdoor unit.
How loud is it?
MRCOOL lists 55.5 / 49.5 / 43.5 / 38 / 27.5 dB(A) from turbo down to silent mode.
What's the warranty?
MRCOOL covers parts, including the pre-charged line set, for 5 years and the compressor for 7 years from your proof-of-purchase date, with no registration needed. See the warranty section above for details.
Pictures and video
See the MRCOOL DIY 5th Gen up close
The DIY 5th Gen in 25 seconds
A short video from MRCOOL. It shows the outdoor unit and what is new in the 5th Gen, like R-454B refrigerant.
8 things to know








This is the indoor unit by itself. It pairs with the 36,000 BTU outdoor unit. Want both in one order? See the complete 36,000 BTU system. This indoor unit also fits the DIY 5th Gen multi-zone outdoor units. The Multi Room Builder helps you pick those parts.
Pictures and video are from MRCOOL. They show the complete system.
Watch MRCOOL install one (6 minutes)
MRCOOL's own install video. It walks through the same 10 steps as the quick start guide in the box, from the wall plate to the first start.
Can you put it in yourself? Yes. MRCOOL made the DIY 5th Gen for do-it-yourself install. The line set comes filled with refrigerant and screws on with two wrenches. You do not need a vacuum pump, gauges or a refrigerant license.
The whole 36,000 BTU DIY 5th Gen install, step by step
- Put up the wall plate.0:00 Take the metal plate off the back of the indoor unit. Use the paper template to mark the screw holes on wall studs. Make the plate level and screw it on. Keep the unit at least 6 ft above the floor.
- Drill the wall hole.1:04 Drill one 3.54 inch (90 mm) hole through the wall. Tilt it down a little toward the outside so water runs out. Slide in the plastic wall sleeve.
- Get the lines ready.1:26 Gently bend the copper lines on the indoor unit so they point straight back. Bundle them with the drain hose. Keep the drain hose on the bottom.
- Hang the indoor unit.1:40 Push the bundle through the hole. Hook the unit on the top of the plate. Press the bottom in until it clicks. Get a helper for the lift.
- Plug in the USB smart dongle.2:03 Open the small USB cover on the indoor unit with a screwdriver. Plug in the dongle and snap the cover back on.
- Set the outdoor unit.2:27 Put it on a level pad or a wall bracket and bolt it down. Leave room for air around it. Unroll only as much line set as you need.
- Hook up the Quick Connect lines.2:54 Pull off the plastic seals. Start each fitting by hand so it goes on straight. Hold one wrench still and turn only the nut marked 2 with the other. No tape and no pipe dope.
- Open the two valves.3:46 Take off each brass cap with a 19 mm wrench. Turn each valve to the left with the 5 mm Allen key until it stops. Put the caps back on tight. Check every fitting with leak spray or soapy water. Bubbles mean a leak.
- Do the wiring.4:53 Turn the breaker off first. Open the wiring cover on the outdoor unit. The DIYPRO cable from the indoor unit and the power from your home both connect here. Match each wire to the diagram inside the cover. Tighten the screws and close the cover.
- Turn it on and test it.5:45 Put the batteries in the remote and turn the power on. Run Cool and Heat. MRCOOL says to test it for at least 30 minutes and to check the fittings for leaks again while it runs.
Tools you need
- Drill and a 3.5 inch (90 mm) hole saw
- Two adjustable wrenches, or open-end wrenches (19, 24, 26, 29 and 31 mm)
- 5 mm Allen key (one comes in the box)
- Phillips screwdriver
- Level, tape measure and stud finder
- Leak spray or soapy water
- Gloves and eye protection
Before you start
- Power: the outdoor unit is wired to its own 208-230V circuit. The biggest breaker it can use is 35 amps. If your home does not have that circuit yet, have an electrician add it.
- Line set: it is 25 ft long. Do not cut it. Coil the extra and lay it flat behind the outdoor unit.
- Bends: keep every bend wider than a 4 inch radius so the copper does not kink.
- The fittings seal one time. Pick both spots before you hook them up.
- Room: the room must be at least 106 sq ft when the unit is 6 to 7.3 ft up. It can be smaller if the unit is higher. See the table in the manual. The ceiling must be at least 7.3 ft high.
- Weight: the indoor unit weighs about 49 lb and the outdoor unit about 152 lb. Get a helper.
These steps follow MRCOOL's quick start guide and its installation manual (version date August 5, 2026). The times show where each step starts in the video. Read the quick start guide (PDF) and the full manual (PDF) before you start.
Day to day
Using the DIY 5th Gen
Controls
- Five modes: Auto, Cool, Heat, Dry and Fan.
- Follow Me: the remote reads the temperature where you are and tells the unit.
- Turbo: the strongest fan, to heat or cool the room fast.
- Silence and Sleep: run quieter and use less power at night.
- Timer: turn on or off in up to 24 hours.
Set up the phone app
- The smart kit is a small USB dongle. It comes in the box.
- Plug it into the indoor unit (step 5 above).
- Get the MRCOOL SmartHVAC app on your iPhone or Android phone.
- Follow the setup sheet that comes with the kit to add your unit.
- After that, you can use Amazon Alexa or Google Assistant too.
Care
- Clean the filter every two weeks. Lift the front panel, pull the filter out, wash it in warm water with mild soap and let it air dry.
- Active Clean: press Clean on the remote. The unit cleans itself and shuts off in 20 to 45 minutes.
- Long break: clean the filters, run Fan until the unit is dry, then turn it off and cut the power.
- Cools when it is -13°F to 122°F outside. Heats when it is -13°F to 75°F outside.
Compare
Pick your size and see how it compares
The five DIY 5th Gen single-room indoor units
| Size | Room size | Power | Biggest breaker | SEER2 | Quiet as |
|---|---|---|---|---|---|
| 9,000 BTU | Up to 400 sq ft | 115V | 20 amps | 23.6 | 18 dB(A) |
| 12,000 BTU | Up to 550 sq ft | 115V | 20 amps | 23.5 | 18 dB(A) |
| 18,000 BTU | Up to 800 sq ft | 208-230V | 20 amps | 22.5 | 19 dB(A) |
| 24,000 BTU | Up to 1,050 sq ft | 208-230V | 25 amps | 22.7 | 20 dB(A) |
| 36,000 BTUThis one | Up to 1,550 sq ft | 208-230V | 35 amps | 18 | 27.5 dB(A) |
Swipe sideways to see it all.
DIY 5th Gen vs. window AC, portable AC and a regular mini split
| DIY 5th Gen | Window AC | Portable AC | Regular mini split | |
|---|---|---|---|---|
| Heats and cools | Yes, both | Most only cool | Most only cool | Yes, both |
| Who puts it in | You | You | You | Most need an HVAC company |
| Tools for the lines | Two wrenches | None | None | Vacuum pump and gauges |
| Uses your window | No | Yes | Yes, for the hose | No |
| Stays up all year | Yes | Often comes out in winter | Often put away in winter | Yes |
| Noise in the room | As low as 27.5 dB(A) | Compressor sits in the window | Compressor sits in the room | Low. Compressor is outside |
| Power | Its own 208-230V circuit | Wall outlet | Wall outlet | Its own circuit |
Swipe sideways to see all four.
Not sure which size fits your room? Use our one-room picker.
What size hole do I drill?
One hole, 3.54 inches (90 mm) wide. Tilt it down a little toward the outside so water drains out. The plastic wall sleeve comes in the box.
Can I cut the line set if it is too long?
No. It is filled with refrigerant. Coil the extra and lay it flat behind the outdoor unit.
Can I take the fittings apart and use them again?
MRCOOL says the Quick Connect fittings are made to go on one time. Taking them apart can hurt the seal and the warranty. Pick both spots before you hook them up.
Can I plug it into a wall outlet?
No. The outdoor unit is wired to its own 208-230V circuit with a breaker up to 35 amps. If your home does not have that circuit yet, have an electrician add it.
How high does the indoor unit go?
At least 6 ft above the floor. Leave 5.9 inches open above it and 4.72 inches open on each side.
What tools do I need?
A drill with a 3.5 inch hole saw, two adjustable wrenches, a 5 mm Allen key, a Phillips screwdriver, a level, a tape measure, and leak spray or soapy water.
Does it need a drain?
Yes. Water from the indoor unit runs out through a drain hose. The hose goes through the same wall hole as the lines. It has to run downhill with no kinks.
How often do I clean the filter?
Every two weeks. Lift the front panel, pull the filter out, wash it in warm water with mild soap and let it air dry.
How heavy are the two units?
The indoor unit weighs about 49 lb and the outdoor unit about 152 lb. Get a helper for the lifts.
How loud is it?
Indoors it runs as low as 27.5 dB(A) on Silent. The outdoor unit is rated 60.5 dB(A).
What refrigerant does it use?
R-454B. The outdoor unit and the line set come filled at the factory. You do not add any.
Comes with a 25 ft DIYPRO cable. It links this inside unit to the outside unit and carries its power, so you do not need to buy one. For a longer run, the 35 ft and 50 ft line sets come with a longer cable.







