Not what you were looking for? Find your system:
MRCOOL DIY 5th gen Multi-Zone Mini-splits
MRCOOL DIY 5th Gen 55,000 BTU 6-Zone Outdoor Unit Only, 230V (Indoor Units Sold Separately) (DIY-MULTI6-55HP230D-O)
Model DIY-MULTI6-55HP230D-O
Outdoor unit only. It runs up to 6 indoor units, one for each room. The indoor units are sold separately.
Build my multi-room systemAlready have the indoor units? Add this one to your cart below.
- Cooling47,000 BTU
- Efficiency22.0 SEER2
- Heating10.6 HSPF2
- Power208-240V
- RefrigerantR-454B
- Heats and cools up to 6 rooms from one outdoor unit
- Made for do-it-yourself installation with MRCOOL's pre-charged Quick Connect line sets
- 55,000 BTU total capacity, shared across the rooms
- 22 SEER2 efficiency to keep power bills down
- Control it with the remote, your phone, Alexa or Google Assistant
In stock
Free shipping · Ships in 1–2 business days
Secure checkout through Shopify
- Authorized MRCOOL dealer
- Licensed HVAC contractor
- Free shipping
- 30-day returns
- Free cancellation before it ships
Authorized MRCOOL dealer. You get new, genuine MRCOOL equipment with the full MRCOOL warranty. A licensed HVAC pro answers your texts.
About usRun by a licensed HVAC contractor. Text our team your sizing or install questions, Monday to Friday, 8 AM to 5 PM Central.
About usThis ships free. Orders under $300 ship for $19.95. You get tracking by email when it ships.
Shipping details30-day returns. Ask within 30 days of delivery. Returns ship back by carrier from your home. Send it back unopened for a refund, minus a 15% restocking fee. If it arrives damaged, broken or wrong, there is no fee and we pay the return shipping.
Return policyFree cancellation. Cancel before your order ships and you pay nothing.
Return policy Questions? Text a licensed HVAC pro. (479) 488-3576 · Mon to Fri, 8 AM to 5 PM CentralProduct overview
About this unit
The MRCOOL DIY 5th Gen 55,000 BTU 6-zone outdoor unit (model DIY-MULTI6-55HP230D-O) runs up to 6 indoor units from one outdoor unit, so each room gets its own temperature control. It runs on 208/230V power and is rated 22 SEER2 and 10.6 HSPF2. MRCOOL rates it for up to 2,290 sq ft across all rooms under ideal conditions.
What you need to complete the system
Indoor units and line sets are sold separately. Each room needs a DIY 5th Gen indoor unit, either wall-mounted (6,000 to 36,000 BTU) or an OuttaSight ceiling cassette (6,000 to 18,000 BTU), and its own line set sized for that unit. Our multi-room builder checks the sizes and adds the matching line sets for you.
Electrical and sound
The outdoor unit needs its own dedicated 208/230V circuit. It runs at 64 dB(A).
Buying from Cool Air Depot
- Authorized MRCOOL dealerNew equipment with the full MRCOOL factory warranty.
- Free shippingThis item ships free.
- 30-day returnsRequest a return within 30 days of delivery, or cancel free before your order ships. Return policy
- Licensed HVAC supportText a pro at (479) 488-3576, Monday to Friday, 8 AM to 5 PM Central.
What's included
What's in the box
In the box
- Outdoor unitDIY-MULTI6-55HP230D-O
Not included: indoor units and line sets. Each room needs its own indoor unit and a line set sized for that unit. Build a multi-room system to choose both.
Specifications
Specs
Capacity
| Maximum zones | 6 |
|---|---|
| Cooling capacity (Btu/h) | 47000 |
| Heating capacity (Btu/h) | 55000 |
Efficiency
| SEER2 | 22.0 |
|---|---|
| EER2 | 12.0 |
| HSPF2-4 brochure | 10.6 |
| HSPF2-5 | 8.5 |
Coverage
| Max coverage area (sq ft, ideal) | Up to 2290 |
|---|
Noise
| Outdoor dB(A) | 64.0 |
|---|
Electrical
| Power supply | 208-230V, 60Hz, 1Ph |
|---|---|
| Outdoor MCA (A) | 43.0 |
| Outdoor max fuse (A) | 45 |
Dimensions
| Outdoor net WxDxH (in) | 37.48 x 16.34 x 52.48 |
|---|---|
| Outdoor packing WxDxH (in) | 43.11 x 19.49 x 58.27 |
Weight
| Outdoor net/gross (lb) | 245.81 / 276.46 |
|---|
Refrigerant
| Type | R-454B |
|---|---|
| Charge (oz) | 151.68 |
Piping
| Liquid / gas size shown in brochure (in) | 3/8 / 5/8 |
|---|---|
| Standard length per indoor unit (ft) | 24.6 |
| Max length for one indoor unit ft | 75 |
| Max total length for all rooms ft | 221 |
| Max height difference indoor to outdoor (ft) | 33 |
| Max height difference between indoor units (ft) | 24 |
| Additional refrigerant, 1/4 in liquid line (oz/ft) | 0.16 |
| Additional refrigerant, 3/8 in liquid line (oz/ft) | 0.32 |
Figures come from MRCOOL's spec sheet, installation manual and AHRI certificate for this model. MRCOOL notes that spec sheet figures may change during production.
Installation
How a DIY install works
- 1Pick the spots
Follow the manual for indoor unit height, ceiling height, minimum room area and clearances around both units.
- 2Mount the units
Mount the indoor unit as the manual shows, and bolt the outdoor unit to a pad or wall bracket.
- 3Connect the Quick Connect line set
Thread each fitting by hand and tighten it with two wrenches. There's no vacuuming and no refrigerant to add. Check every joint with leak-detection spray.
- 4Open the valves
Open the outdoor unit's valves with a 5 mm Allen key, as the manual shows.
- 5Power and first start
Connect the DIYPRO cable and wire the power circuit to local code.
Power and tools
Electrical
- Power supply
- 208-230V
- Minimum circuit ampacity
- 43.0 A
- Maximum breaker or fuse
- 45 A
Warranty
MRCOOL's factory warranty
Covered
- Starts on your proof-of-purchase date. No registration is needed.
- Parts include the remote, the Wi-Fi dongle, the pre-charged line sets and the parts inside the indoor and outdoor units (the compressor has its own 7-year term).
Warranty exclusions
- Labor, shipping and refrigerant costs
- Damage from an install that doesn't follow the manual, local codes or permits
- A unit moved from its first install address
Summary of MRCOOL's limited warranty for the 5th Gen DIY series (rev. 07.03.25). The PDF below is the full terms. MRCOOL may ask for a licensed HVAC technician to diagnose a problem before approving a claim. Claims go to MRCOOL at (270) 366-0457 or support@mrcool.com.
Documents
Manuals and documents
Install and use
Specs and ratings
Warranty
For your installer
Other documents
Check the ratings yourself: enter AHRI reference number 216032598, date 2025-02-19 and certificate number 133844592047887008 at ahridirectory.org.
FAQ
Questions people ask
Still have a question? A licensed HVAC pro answers texts Monday to Friday, 8 AM to 5 PM Central.
Text a pro: (479) 488-3576Which line set does it use?
Each indoor unit needs its own DIY 5th Gen Quick Connect line set, sold separately.
How big a space will it handle?
MRCOOL rates it for up to 2290 sq ft.
What's the warranty?
MRCOOL covers parts, including the pre-charged line set, for 5 years and the compressor for 7 years from your proof-of-purchase date, with no registration needed. See the warranty section above for details.
Pictures and video
See the MRCOOL DIY Multi-Zone up close
The DIY Multi-Zone in 27 seconds
A short video from MRCOOL. One outdoor unit heats and cools up to six rooms, and you can put it in yourself.
8 things to know








This is the outdoor unit by itself. Add 2 to 6 indoor units and a line set for each one. The Multi Room Builder helps you pick all the parts together.
Pictures and video are from MRCOOL.
Watch MRCOOL install a DIY Multi-Zone (4 minutes)
MRCOOL's own install video. It shows an earlier DIY Multi-Zone model. The job is the same: hang an indoor unit in each room, run a line set to each one, hook them up and wire it.
Can you put it in yourself? Yes. MRCOOL made the DIY Multi-Zone for do-it-yourself install. The line sets come filled with refrigerant and screw on with two wrenches. You do not need a vacuum pump, gauges or a refrigerant license.
MRCOOL DIY Multi-Zone installation, step by step
- Plan the rooms and the ports. The ports on the outdoor unit have letters: A, B, C and so on. The biggest indoor unit goes on port A, the next biggest on B, and so on down.
- Put up each wall plate. Use the template to mark the screw holes. Make the plate level and screw it on. Keep each indoor unit at least 5.9 ft above the floor, with 5.9 inches open above it and 4.72 inches open on each side.
- Drill a wall hole for each indoor unit. Each hole is 3.54 inches (90 mm) wide. Tilt it down a little toward the outside so water runs out. Slide in the plastic wall sleeve.
- Hang each indoor unit. Bundle the lines with the drain hose on the bottom. Push the bundle through the hole and hook the unit on its plate. Get a helper for the lift.
- Set the outdoor unit. Put it on a level pad or a wall bracket and bolt it down with M10 bolts. Leave room for air around it.
- Run a line set to each indoor unit. Do not cut a line set. Coil the extra and lay it flat behind the outdoor unit. Keep every bend wider than a 4 inch radius.
- Hook up the Quick Connect lines. The labels on the connectors have to match the labels on the indoor unit and on the outdoor unit port. Start each fitting by hand so it goes on straight, then tighten it with two wrenches. No tape and no pipe dope.
- Open the valves. Take off each valve cap with a 19 mm wrench. Turn each valve to the left with the 5 mm Allen key until it stops. Do not force it. On 4, 5 and 6-zone units, open the two King valves the same way. Put the caps back on tight.
- Check for leaks. Spray every fitting with leak spray or soapy water. Bubbles mean a leak.
- Do the wiring. Turn the breaker off first. Each indoor unit has a DIYPRO cable. It goes to the terminals on the outdoor unit with the same letter as its port. The power from your home connects to the outdoor unit. Match each wire to the diagram.
- Turn it on and test it. Make sure every valve is open first. Run Cool and Heat for 5 minutes each. MRCOOL says to test for at least 30 minutes and to check the fittings for leaks again while it runs.
Tools you need
- Drill and a 3.5 inch (90 mm) core drill or hole saw
- Two adjustable wrenches. Or open-end wrenches: 19, 22, 24 and 26 mm for indoor units up to 18K, and 19, 24, 26, 29 and 31 mm for 24K and 36K
- 5 mm Allen key (one comes in the box)
- Phillips screwdriver
- Level, tape measure and stud finder
- Leak spray or soapy water
- Gloves and eye protection
Before you start
- Power: the outdoor unit is wired to its own 208-230V circuit. The biggest breaker it can use is 45 amps. If your home does not have that circuit yet, have an electrician add it.
- Indoor units: hook up 2 to 6 of them. They are sold one by one, so you pick the size for each room.
- Line sets: each indoor unit needs its own DIY line set, sold on its own. One line can run up to 75 ft. All the lines together can add up to 221 ft.
- Height: an indoor unit can sit up to 33 ft higher or lower than the outdoor unit. Indoor units can be up to 24 ft apart in height.
- Adapter: a 24K or bigger indoor unit uses the line set adapter on port A. MRCOOL packs the adapter with those indoor units.
- Weight: the outdoor unit weighs about 246 lb. Get help to move it.
These steps follow MRCOOL's DIY Multi-Zone installation manual (version date January 8, 2026). Read the full manual in the Manuals part of this page before you start. Have a 24K indoor unit on a 5-zone outdoor unit? MRCOOL has a short adapter video.
Day to day
Using the DIY Multi-Zone
Controls
- A remote for each room. Each indoor unit has its own remote and its own temperature.
- Five modes: Auto, Cool, Heat, Dry and Fan.
- One season at a time: all the rooms heat or all the rooms cool. If rooms ask for both, heat wins.
- Follow Me: the remote reads the temperature where you are and tells the unit.
- Silence and Sleep: run quieter and use less power at night.
- Timer: turn on or off in up to 24 hours.
Set up the phone app
- A Smart Controller Kit comes with each indoor unit.
- Follow the setup sheet in the remote box to hook it up.
- Get the MRCOOL SmartHVAC app on your iPhone or Android phone.
- Add each room to the app, one at a time.
- After that, you can use Amazon Alexa or Google Assistant too.
Care
- Clean each filter every two weeks. Open the front panel, lift the filter out, wash it in warm soapy water and let it dry out of the sun.
- Active Clean: press Clean on the remote. The unit cleans itself and shuts off in 20 to 45 minutes.
- Cools when it is -22°F to 122°F outside. Heats when it is -22°F to 75°F outside.
How many indoor units can I hook up?
From 2 to 6. You do not have to use every port.
Which indoor unit goes on which port?
The ports have letters. The biggest indoor unit goes on port A, the next biggest on port B, and so on. The labels on the connectors have to match the labels on the units.
How long can the lines be?
Each indoor unit can have up to 75 ft of line. All the lines together can add up to 221 ft.
Can I cut a line set if it is too long?
No. It is filled with refrigerant. Coil the extra and lay it flat behind the outdoor unit.
Can one room heat while another room cools?
No. All the rooms heat or all the rooms cool at one time. If rooms ask for both, heat wins. Each room still sets its own temperature.
What if I hook a line or a cable to the wrong port?
The outdoor unit has a check that can fix a mixed-up line or cable. MRCOOL's manual says to hold the check switch on the outdoor board until CE shows. It takes about 5 to 10 minutes and works when it is above 41°F outside.
What size hole do I drill?
One hole for each indoor unit, 3.54 inches (90 mm) wide. Tilt it down a little toward the outside so water drains out.
Can I plug it into a wall outlet?
No. The outdoor unit is wired to its own 208-230V circuit with a breaker up to 45 amps. If your home does not have that circuit yet, have an electrician add it.
How often do I clean the filters?
Every two weeks. Open the front panel, lift the filter out, wash it in warm soapy water and let it dry out of the sun.
What refrigerant does it use?
R-454B. The outdoor unit and the line sets come filled at the factory.