MRCOOL 24,000 BTU Mini Split: Compare 2-Ton Systems

MRCOOL DIY 5th Gen 24,000 BTU system with wall mounted indoor unit, outdoor condenser and Quick Connect line set

Kevin, licensed HVAC contractor |

Updated · About the author

Choosing an MRCOOL 24,000 BTU mini-split comes down to the space, the installation and the complete package. Select offers a lower-priced DIY starting point. Easy Pro has two different line-set packages. DIY 5th Gen leads the R-454B wall systems below in seasonal cooling efficiency, while professionally installed Olympus E Star leads them in seasonal heating efficiency.

“24K” is the nominal 2-ton size class. This guide compares complete wall-mounted single-zone systems at Cool Air Depot, explains the separate fourth-generation listing, and shows when a multi-zone or ducted system is a better type of equipment to investigate.

Shop every MRCOOL 24,000 BTU system

You can buy every system in this guide right here. Cool Air Depot is an official MRCOOL dealer. Each one ships free.

Shop 24,000 BTU systems:

Which MRCOOL 24K package should you consider?

  • Lower equipment price for a DIY project: DIY Select 24K is $1,899, with either a white or black indoor unit. It includes an 11.5-foot pre-charged line set.
  • Comparing an 11.5-foot or 16-foot route: the Easy Pro 11.5-foot kit is $2,109; the Easy Pro 16-foot kit is $2,149. Their efficiency ratings match, but their standard warranties differ. Read the Easy Pro package comparison before choosing.
  • Higher cooling efficiency with a longer included line set: the DIY 5th Gen 24K wall system is $3,329, with a 25-foot pre-charged line set and a 22.7 SEER2 rating.
  • Having an HVAC contractor install it: Advantage 24K has the lowest equipment price in this comparison at $1,462. Olympus E Star 24K is $2,302 and has higher seasonal efficiency ratings, but its copper line set and several installation materials are separate purchases.

Is 24K right for your living area, garage or basement?

MRCOOL's rough sizing guide places 24K in the up-to-1,050-square-foot range with 8-foot ceilings. That is a starting estimate. A heating and cooling load calculation accounts for the building and climate before equipment is selected.

  • A larger connected living area: include the entire open space and consider where the head can deliver air without obstructions.
  • A garage, workshop or basement: ceiling height, insulation, windows, door leakage, moisture and how the space is used can change the project. Floor area alone does not settle the equipment size.
  • Several enclosed rooms: check each room's load and air-delivery needs. One larger head does not automatically distribute air through closed doors.

Use our mini-split sizing guide to organize the measurements. If the calculation points to another size, compare the adjacent 18K guide or 36K guide. Do not move up a size solely because a room has extra windows or a high ceiling.

A 2-ton wall system and a 2-ton central system serve different layouts

A single-zone wall head delivers conditioned air into its own space. Central equipment distributes it through ductwork. PNNL's ductless heat-pump guidance explains why the room layout and air-distribution plan matter alongside capacity.

For separate rooms, compare our multi-zone guide and room-by-room system builder. For a home using existing ducts, compare the 2-ton VersaPro central system or 2-ton Central Ducted Hyper Heat system. Those are different equipment configurations from the wall packages below.

Compare complete 24K packages, line sets and prices

Every row below includes one wall-mounted indoor unit and one matching outdoor unit. These R-454B packages use 208/230V single-phase power. Prices are Cool Air Depot equipment prices in USD, checked November 8, 2026; they exclude tax, installation, electrical work and additional project accessories. Follow a product link for its current price and availability.

R-454B wall systems: package contents and equipment price
System and installation Included line set Equipment price
DIY Select
DIY · white or black
11.5 ft pre-charged Quick Connect $1,899
DIY Easy Pro
DIY · 11.5 ft DE kit
11.5 ft pre-charged Quick Connect $2,109
Easy Pro 5th Gen
DIY · 16 ft D kit
16 ft pre-charged $2,149
DIY 5th Gen
DIY · 25 ft kit
25 ft pre-charged Quick Connect $3,329
Advantage 5th Gen
Professional install
16 ft pre-flared installation kit $1,462
Olympus E Star
Professional install
Copper line set sold separately $2,302

The Select row covers two separately linked indoor-color choices at the same price. Advantage's pre-flared kit still requires professional refrigerant-system installation; it is different from the sealed, pre-charged line sets supplied with the DIY packages. A component-only indoor or outdoor listing is not one of these complete systems.

Compare exact-model capacity and efficiency

Cooling efficiency and heating efficiency are separate buying considerations. SEER2 measures seasonal cooling efficiency; HSPF2 measures seasonal heating efficiency. The heating column below consistently uses HSPF2-4, also called the Region IV rating.

Nominal 24K R-454B systems: rated cooling shown beneath each model
System and rated cooling SEER2 HSPF2-4
DIY Select
23,000 BTU/h cooling
16.5 8.3
DIY Easy Pro · 11.5 ft DE
24,000 BTU/h cooling
18.9 8.7
Easy Pro 5th Gen · 16 ft D
24,000 BTU/h cooling
18.9 8.7
DIY 5th Gen
24,000 BTU/h cooling
22.7 9.5
Advantage 5th Gen
24,000 BTU/h cooling
18.7 9.3
Olympus E Star
24,000 BTU/h cooling
21.0 13.5

Select's rated cooling capacity is 23,000 BTU/h even though it is sold in the 24K size class. These are rated capacities for specific combinations, not their maximum output or promises of capacity in every weather condition.

For a DIY project focused on cooling efficiency, compare DIY 5th Gen. It has the highest SEER2 in this table. For a professionally installed project where heating efficiency matters, compare Olympus. Its 13.5 HSPF2-4 is higher than the other listed R-454B wall combinations. Factor in installation and the separately required materials when comparing cost.

A higher seasonal heating rating does not establish the output available on your coldest day. Review the exact model's performance at your local winter design temperature and the calculated heating load. Our cold-weather heating guide explains that distinction.

Manufacturer references: Select brochure, Easy Pro DE brochure, Easy Pro D brochure, DIY 5th Gen AHRI certificate, Advantage brochure and Olympus brochure (PDFs). Confirm current documentation for the exact indoor/outdoor combination; several brochures note that specifications are preliminary and subject to change.

Select, the two Easy Pro kits, or DIY 5th Gen?

Select versus Easy Pro: what does the extra $210 buy?

The 11.5-foot Easy Pro DE package costs $210 more than Select at this review. Both have an 11.5-foot included line set. Easy Pro has higher rated cooling capacity, SEER2 and HSPF2-4 at this size. Select provides the separately available black indoor-unit choice.

Their standard limited warranties also differ: Select provides one year on parts and two on the compressor; Easy Pro DE provides three years on parts and five on the compressor. Labor is excluded and conditions apply.

What does DIY 5th Gen add?

The DIY 5th Gen 24K package is $1,220 above the 11.5-foot Easy Pro kit and $1,180 above the 16-foot kit at the checked prices. Its 25-foot included line set and higher seasonal ratings are practical reasons to compare it. Its standard limited warranty provides five years on parts and seven on the compressor, with no registration required for that standard coverage; labor is excluded and conditions apply.

Measure first. The longer included line set can suit a longer route, but the equipment-price premium is not proof of lower total cost or a particular energy-savings payback.

What about the fourth-generation 24K system?

The separately listed DIY 4th Gen 24K complete system, model DIY-24-HP-WM-230C25, is $2,502 at this review—$827 below the fifth-generation package. It uses R-410A, while the main comparison above covers R-454B equipment.

MRCOOL's fourth-generation brochure lists 23,000 BTU/h rated cooling, 20.5 SEER2 and 9.2 HSPF2-4 for the 24K combination. Treat it as a different generation with its own documentation, rather than a fifth-generation package at a lower price. Confirm the package contents and approved components for the exact model before ordering.

Similarly, a 24K ceiling cassette, ducted air handler or outdoor-only listing is a component choice, not automatically a complete replacement for a wall kit. Use the ceiling-cassette guide when that indoor style is your goal, and verify the approved indoor/outdoor pairing.

Power, circuit and breaker questions

All complete 24K systems discussed here use 208/230V single-phase power. Plan the dedicated supply, disconnect and wiring with an electrician. The shared voltage does not mean every model has the same circuit requirements.

For the specific DIY 5th Gen outdoor model DIY-24-HP-C-230D25-O, MRCOOL lists 24 A minimum circuit ampacity and a 25 A maximum fuse rating. These are different specifications: minimum circuit ampacity concerns conductor sizing; the maximum rating limits permitted overcurrent protection. Neither figure is a universal instruction for every 24K system.

Use the unit's nameplate and exact installation manual to select the permitted protection and conductor arrangement. Read our 115V versus 230V guide for background.

Installation fit and the full project cost

Before comparing only the checkout totals, check four things:

  1. The indoor location: confirm the exact head's dimensions, mounting space, required clearances and access for filter cleaning. A larger unit needs a location that lets it distribute air through the intended space.
  2. The full line route: measure the actual path through the wall and down to the outdoor unit, including bends and routing. Match the approved line-set length, pipe sizes and connections to the exact model and refrigerant.
  3. The outdoor support and drain route: plan a suitable pad or approved bracket, the required outdoor clearances and a condensate route. Include any extra mounting or drain materials in the project cost.
  4. The labor and electrical scope: a DIY refrigerant connection does not eliminate the electrical work. Advantage and Olympus require professional refrigerant-system installation as well.

Olympus's copper line set, communication cable and condensate drain hose are sold separately. Advantage includes a 16-foot pre-flared installation kit but still needs an HVAC installer. Compare a written installed quote for those systems with the equipment, electrical work and extra materials required for a DIY project.

For the listed DIY 5th Gen 24K, the manufacturer specifies 3/8-inch liquid and 5/8-inch gas connections. Verify generation and model compatibility before choosing a longer line set or coupler; pipe diameter alone does not establish compatibility. See our line-set sizing and routing guide and DIY installation guide.

MRCOOL DIY 5th Gen complete system
DIY 5th Gen 24,000 BTU, 230VOne room up to 1,050 sq ft. Complete system with a 25 ft line set. Free shipping.
Shop the 24K

Common MRCOOL 24,000 BTU buying questions

How many square feet can a 24,000 BTU MRCOOL serve?

MRCOOL's rough sizing guide uses up to 1,050 square feet for the 24K class with 8-foot ceilings. Insulation, windows, climate, room layout and internal heat gains change the load. Use a heating and cooling load calculation to confirm the size; the floor-area estimate is not a guarantee.

What is the difference between the two Easy Pro 24K kits?

The EZPRO-24-HP-23011DE-O includes an 11.5-foot line set and standard three-year parts/five-year compressor coverage. The EZPRO-24-HP-23016D-O includes a 16-foot line set and standard one-year parts/two-year compressor coverage. Both are rated 18.9 SEER2 and 8.7 HSPF2-IV. Warranty conditions and exclusions apply.

Which 24K model has the highest cooling or heating efficiency?

Among the R-454B wall systems compared here, DIY 5th Gen has the highest SEER2 cooling rating at 22.7. Olympus E Star has the highest HSPF2-IV heating rating at 13.5 and requires professional installation. Seasonal ratings do not predict an exact utility bill or the heating capacity available on your coldest day.

Can one 24K wall unit heat and cool several separate rooms?

One wall head supplies air directly to its own space. A combined floor area below 1,050 square feet does not establish that closed rooms will receive enough heating or cooling. Compare room-by-room loads and air distribution before choosing a single-zone, multi-zone or ducted system.

Is a 2-ton mini-split the same as a 2-ton central system?

Both use the same nominal capacity class, but they distribute air differently. The single-zone wall packages in this guide include one indoor head and one matching outdoor unit. A central system uses an air handler and ductwork to serve rooms. Match the equipment type to the home's layout and calculated loads.

Are these 24,000 BTU systems available in 115V?

All complete 24K systems compared in this guide use 208/230V single-phase power. They are not 115V plug-in appliances. Have an electrician check the dedicated supply, disconnect, wiring and protection against the exact model's nameplate and installation instructions.

What breaker does a DIY 5th Gen 24K need?

For outdoor model DIY-24-HP-C-230D25-O, MRCOOL lists a 24 A minimum circuit ampacity and a 25 A maximum fuse rating. Those figures are specific to that model. An electrician must select the conductors and permitted overcurrent protection using the nameplate, instructions and applicable requirements; do not apply this example to every 24K unit.

Can I mix fourth- and fifth-generation 24K components?

Do not choose compatible equipment by the 24K label alone. The fourth-generation package discussed here uses R-410A, while the compared fifth-generation and newer packages use R-454B. Indoor units, outdoor units, refrigerant lines and connections must form a manufacturer-approved combination for the exact models.

What is the standard DIY 5th Gen warranty?

MRCOOL's standard limited warranty provides five years of parts coverage and seven years of compressor coverage for the listed DIY 5th Gen system, with no registration required for that standard coverage. Labor is excluded, and installation, use and claim conditions apply. Extended programs have separate requirements.

Choose the package that fits your project

Compare the included line length, installation plan and exact-model ratings before choosing your 24K system.

View Easy Pro 11.5 ft kit View DIY 5th Gen 24K

Need to check a model match or package detail? Ask a product question. You can also browse all single-zone systems.